• Title/Summary/Keyword: 분두

Search Result 7, Processing Time 0.017 seconds

A study on Development of a Pneumatic Granular Applicator for Paddy Field (I) - Granular Discharge Rate, Diffuser and Optimal Application Conditions - (수도작용 송풍식 입제살포기 재발에 관한 연구 (I) - 입제 배출량, 분두 및 적정살포조건 -)

  • 정창주;정선옥;장영창;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.22 no.2
    • /
    • pp.127-136
    • /
    • 1997
  • This study was accomplished to develop a pneumatic granular applicator that can be attached to the conventional ride-on rice transplanter. Operating conditions of a metering device for the applicator were determined so as to obtain the required discharge rate of granules for field application. The shape and size of diffuser was selected for the applicator and the spacing between diffusers on a boom and the boom height were determined as an optimal application condition for uniform distribution. The diffuser spacing of 1m for the fertilizer and the diffuser spacing of 0.8m for the pesticide at the boom height over 0.8m were acceptable.

  • PDF

Theoretical Analysis on the Swirl Type Nozzle(III) -Effects of Forces on the Droplet Formation- (와권(渦券) 노즐의 이론분석(理論分析)(III) -힘이 입자형성(粒子形成)에 미치는 영향(影響)-)

  • Lee, S.W.;Sakai, Jun
    • Journal of Biosystems Engineering
    • /
    • v.14 no.3
    • /
    • pp.196-206
    • /
    • 1989
  • 와권(渦券) 노즐에 작용(作用)되는 힘은 분두(噴頭)의 도구(導溝) 및 와실(渦室)의 기능(機能)에 의하여 축방향력(軸方向力)과 반경방향력(半徑方向力)으로 분류(分類)되고, 이 두 개의 힘은 미립화(微粒化)의 과정(過程)에 각각(各各)의 특성(特性)을 주고 있다. 반경방향(半徑方向)의 힘은 분두(噴頭)에서 분사(噴射)되는 입자(粒子)에 전단력(剪斷力)으로서 작용(作用)하지만 이 힘의 크기는 물방울의 직경(直徑) $100{mu}m$을 기준(基準)하여 2.4m/s의 속도(速度) 이내(以內)의 범위(範圍)이었으며, 그 속도범위(速度範圍)는 다음 유도된 식(式)으로 산출(算出)할 수 있었다. $$V_{ot}=(\frac{8g{\sigma}}{d{\gamma}})^{1/2}$$ 축방향력(軸方向力)은 아래 유도된 식(式)과 같이 분사액류(噴射液流)의 굴절각에 매우 민감하게 영향을 미치었고, 그 크기는 반경방향력(半徑方向力)에 비교(比較)하여 큰 값을 나타내었다. $$V_{\ell}={\sigma}[\frac{1}{2}{\rho}_{a}sin2{\theta}_d-4({\mu}+{\eta})\frac{\ell}{r_o}]^{-1}$$.

  • PDF

Study on the Nozzle Spacing in the Boom-Type Nozzle System (Boom-Type Nozzle System의 분두배치(噴頭配置)에 관(關)한 연구(硏究))

  • Seo, Jeoung Duk;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.2
    • /
    • pp.212-223
    • /
    • 1981
  • The proper nozzle spacings have been tried to determined the better evenness of distribution on the development of the boom type nozzle system with three nozzles made in Korea-disk type, cap type and bolt type. The operating pressure has been changed in 7 levels ($2kg/cm^2-8kg/cm^2$) and the operating height in 3 levels (30, 40, 50cm) to find characteristics of deposit pattern and the proper spacing of each nozzle was examined and computed. The results of this study were as follows; 1. The CU(%) of the deposit distribution was improved with the operating pressure of $5kg/cm^2$ or $6kg/cm^2$ in Nozzle A with 80% and Nozzle C with 83%, and $7kg/cm^2$in Nozzle B with 80% 2. The better deposit distribution was got ten at operating height 40cm with CU 86% in Nozzle A, and 50cm in both Nozzle B, C with 80% 3. The spray deposit distribution was getting of improvement with decrease of nozzle spacing, nevertheless about half diameter of the spraying circle was recommended in regard to the cost and the work performance. 4. Improvement of quality of nozzles tested in this research may be required not to be less than their CU 90% in the use as boom-type nozzle system.

  • PDF

Performance of Mini-Sprinkler - (2) Size of Droplets (미니 스프링클러의 살수 기능 - (2) 살수 입자의 크기)

  • 서상룡;성제훈
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 1997
  • This study was performed to Investigate size of droplet sprinkled from mini-sprinkler. Twelve different kinds of the sprinkler having various structures and sizes of nozzle orifices were selected and tested. Diameters of the droplet reached at several distances from a sprinkler were measured by a machine vision system and the volume median diameters (VMM) were determined statistically. The size of droplet was not affected much by the size of nozzle orifice of a sprinkler but was rather more affected by structure of the sprinkler, especially by the shape of spreader of the sprinkler. Experiment of varying pressure of sprinkling water validated that the size of droplet was inversely proportional to water pressure powered by 1/3. Hence the size of droplet at any water pressure could be easily estimated from experimental data. The size of droplet increased as travel distance of the droplet increases in a relationship of and order function. The size of droplet of the tested sprinkler were in the ranges of 100-300fm within 1m of droplet travel distance, 230~470${\mu}{\textrm}{m}$ within 1~2m of droplet travel distance and 300~770${\mu}{\textrm}{m}$ within 2~3m of droplet travel distance.

  • PDF

Study on the Improvement of Distribution Pattern in the Triple Nozzle System (동력분무기용(動力噴霧機用) 삼분두(三噴頭)의 살포도(撒布度) 개선(改善)에 관(關)한 연구(硏究))

  • Hong, Soung Wha;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.284-294
    • /
    • 1984
  • Effects of orifice diameter, operating angle and swirl chamber distance were examined to study a reasonable distribution pattern on the maximum available travel distance in the triple nozzle system. The results of the study were as follows; 1. Discharge rate was increased with increase of orifice diameter, and a quadratic line for the 1st nozzle and linear lines for the 2nd or the 3rd nozzle. 2. The operating angle of $15^{\circ}$ had showed the maximum available travel distance, and 17m in orifice diameter of 3.0mm and operating pressure of $24.5{\times}10^5pa$ ($25Kg/cm^2$). 3. Nozzle setting methods (reference Table 6.) for improvement of uniformity of deposit distribution were varied depending on the size of orifice diameter of the 1st nozzle, nevertheless coefficients of uniformity were improved about 6 percents. 4. Adjustment of the swirl chamber distance of the 2nd nozzle could improve the minimum area of about 6m from the triple nozzle.

  • PDF

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 -)

  • Kim, Y.J.;Kim, H.J.;Seo, M.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (IV) - Evaluation of Application Performance and Adjustment Method of Blow Head According to Discharging Rate - (친환경 정밀농업을 위한 입제 변량살포기 개발(IV) - 살포성능 평가와 살포율에 따른 분두 조절 방법 -)

  • Kim, Young-Joo;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.383-388
    • /
    • 2007
  • In precision farming, proper calibration and operation of a variable rate machine are critical to reduce input of agrochemicals and to ensure productivity and quality of agricultural products. As an effort to introduce precision farming to rice production in Korea, a pneumatic granular applicator was developed. This investigation intended to evaluate the application performance such as application accuracy, application uniformity and to suggest how to adjust the blow-heads to get uniform application pattern, and to suggest a practical way of adjustment of the blow-heads for uniform application. Tests to evaluate the application performance were conducted. The application uniformities (CV) in both transverse direction and longitudinal direction were less than 15% and application accuracy was greater than 81%. A simple method for adjusting the inserting length of blow-heads was suggested.