• 제목/요약/키워드: 분기 배관

검색결과 41건 처리시간 0.031초

주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책 (Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header)

  • 김연환;배용채;이영신
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

주증기 배관 헤더의 맥동이 분기 배관에 미치는 영향 (Vibration Effect for Branch Pipe System due to Main Steam Header Pulsation)

  • 김연환;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.780-785
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of a nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve or heather generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 7nn nuclear power plant. The exciting sources and response or the piping system are investigated by using on site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3Hz, 4.4Hz and 6.6Hz transferred from main steam header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness were installed to reduce excessive vibration.

  • PDF

터보펌프식 액체 로켓의 추진제 공급시스템 설계

  • 조기주;이한주;정영석;임석희;김지훈;오승협
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.89-89
    • /
    • 2003
  • 로켓엔진의 연소에 필요한 추진제를 안정적으로 공급하기 위한 추진제 공급시스템의 주요 구성과 설계 주요 인자를 정리하였다 공급시스템은 추진제 주입/배출 장치, 추진제탱크 가압 및 배기 장치, 추진제 공급 주/분기 배관, 극저온 산화제 온도 유지 장치 등으로 구성되어 있다. 주요 설계 제한 조건으로는 터보 펌프 입구에서의 추진제 압력 및 온도, 필요 추진제 공급 유량 및 온도 그리고 추진제 충진 및 비상 배출 허용 시간 등이며 이는 각 로켓의 해당 임무에 따라 적절히 결정된다. 발사체로부터 할당된 중량값 이내에서 고신뢰도의 작동성, 안정성이 보장되는 시스템을 설계하여야 하며 초기 설계 단계에서 개발 및 수급 가능성을 동시에 고려하여야 할 것이다. 또한 고추력 생성을 위해 엔진 클러스터링이 수행되어야 할 경우 각 엔진으로의 균등한 추진제 배분 공급이 설계의 중요한 요구 조건이 된다. 이러한 공급시스템의 개념은 액체산소와 케로신 조합의 액체 로켓인 100kg급 소형 위성 발사체(KSLV-Ⅰ)에 적용될 예정이다.

  • PDF

용접공정 및 용접형상 변화에 따른 소구경 분기배관 용접부의 피로특성 (Fatigue Properties of the Small Diameter Branch Welded Pipe Joint with variation of Welding Procedures and Welding Shapes.)

  • 백종현;김철만;김우식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 추계학술발표대회 개요집
    • /
    • pp.191-193
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of the small diameter socket and butt welded joints of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

소구경 분기배관 용접부의 피로강도에 미치는 용접부 형상 및 용접공정의 영향 (Influence of Welding Shapes and Welding Procedures on Fatigue Strength of Small Diameter Branch Welded Pipe Joint)

  • 백종현;김철만;김우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1092-1097
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 mm. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

원자로 비상 냉각재 누설에 의한 열성층의 비정상 특성에 관한 연구 (Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System)

  • 한성민;최영돈;박민수
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.202-210
    • /
    • 2006
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thormal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, when the turbulence penetration occurs in the branch pipe, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine.

용접부의 형상과 공정변화에 따른 소구경 분기배관의 피로강도 특성평가 (S-N Fatigue Strength of Small Diameter Branch Welded Pipe with Variation of Welding Shapes and Welding Procedures)

  • 백종현;김우식
    • Journal of Welding and Joining
    • /
    • 제22권3호
    • /
    • pp.50-55
    • /
    • 2004
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 m and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

일차 냉각계통 스트레이너에 대한 내진 건전성 평가 (Seismic Evaluation for Strainer in the Primary Cooling System)

  • 정철섭
    • 한국전산구조공학회논문집
    • /
    • 제13권3호
    • /
    • pp.295-304
    • /
    • 2000
  • 본 연구의 목적은 지진하중에 대한 응력 해석을 수행하여 ASME, Class 3 설계요건에 따라 스트레이너의 구조건진성을 평가하는 것이다. 스트레이너에 대한 설계요건이 ASME 코드 내에 명백하게 규정되어 있지 않기 때문에 본체는 밸브 설계요건인 ND-3500을 적용하고, 양쪽 플랜지 연결부는 배관 설계요건 중 ND-3658.3을 적용하였으며, 하단의 덮개 플랜지는 Appendix XI에 따라 설계 및 해석을 수행하였다. 본 연구에서는 T형 스트레이너를 쉘로 모델링하여 유한요소법을 사용하여 지진하중에 의해 스트레이너가 응답하는 모드 형상 및 고유진동수를 계산하여 충분히 강건한 구조물임을 입증한 후 정적 해석을 수행하여 주관과 분기 관이 접합하는 연결부위와 같은 위험단면에서의 막응력과 굽힘 응력을 구하였다. 각 하중조합에 대해 코드에서 규정하고있는 허용 값과 비교한 결과 스트레이너는 지진하중이 작용하는 경우 구조적 건전성을 유지하고 있음을 확인하였다. 아울러 인접 배관을 연결해주는 플랜지 연결부의 응력을 규정에 따라 구한 후 설계요건에 의한 허용 값과 비교하여 건전성을 만족함을 알 수 있었다.

  • PDF

부스닥트용 온도감시 시스템 개발 (Development of temperature monitoring system for bus duct)

  • 김동욱;남석현;박성주;허성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.15-16
    • /
    • 2006
  • 배전선로에 전력을 공급하는 방식은 일반적으로 22.9kV급 XLPE 케이블에 의한 전력공급이 주를 이루어 왔다. 한편으로 대규모 전력을 소비하는 공장 및 고층 빌딩의 전력 공급에 있어서는 일반적으로 각각 부하로의 많은 회선수의 케이블 포설을 요하는 전력케이블 보다는, 한 선로로 보다 많은 대전류를 수송하면서 부하 가까이에서 필요한 전류를 간편하게 분기해 공급받는 부스덕트 시스템이 시공 및 배전선로 관리의 간편성에 의해 점차 용도가 늘어나고 있다. 부스닥트 시스템의 대부분은 일단 시설물이 건축될 때 건축물의 상부 공간 또는 설비가 위치한 하부 바닥 구간을 통해 설치된 이후, 기타 배관, 가스관 등의 추가적인 건축 구조물과 함께 설치되어 이후 선로의 보수 진단 등이 대부분 어렵게 되어진다. 본 논문에서 소개하는 부스덕트의 온도감시 시스템은 아무리 복잡하고 협소한 설치 환경이라도 특수한 포설 공법에 의해 광화이버를 포설하고, 이를 활용하여 실시간으로 부스덕트 선로의 표면온도와 주변온도를 상시 감시함으로써, 효율적인 부스덕트 선로의 활용뿐만 아니라 과열에 의한 절연사고를 미연 방지하는 운전신뢰성과 안정성을 높이는 것이 가능하게 되었다.

  • PDF

다양한 디퓨저 형상의 유량 분배 특성에 관한 수치해석 연구 (Numerical Analysis of Flow Rate Distribution of Diffusers with Various Shapes)

  • 김명수;김후배;최형권
    • 대한기계학회논문집B
    • /
    • 제38권9호
    • /
    • pp.789-795
    • /
    • 2014
  • 본 연구에서는 개방형 축열시스템에 설치되는 다양한 형상을 가진 디퓨저의 유량 분배 특성을 수치해석 하였다. 작동유체가 분기배관의 양 방향으로 나뉘어져 있는 구멍들을 통하여 균등하게 분배되도록 4가지 형상의 디퓨저를 설계하였다. 상용 해석 프로그램인 ANSYS-FLUENT을 사용하여 비압축성 유체의 3차원 정상 층류 유동으로 시뮬레이션을 수행하였다. 한 방향 또는 양 방향으로 분배되는 디퓨저는 유량이 일정하게 분배되지 않는 반면에 양 방향 헤더 형식과 H형 대칭구조의 디퓨저는 균등한 분배 특성을 보였다. 한편, H형 대칭구조의 디퓨저는 양 방향 헤더 형식 디퓨저보다 높은 펌프 양정을 필요로 하므로 유량분배도 일정하고 펌프 양정도 낮은 양 방향 헤더 형식 디퓨저가 최적임을 확인하였다.