• Title/Summary/Keyword: 분기 구조

Search Result 333, Processing Time 0.026 seconds

장대레일 축력해석

  • 강동욱;정근영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.631-645
    • /
    • 2002
  • ●정의 정척레일을 연속 용접하여 1개의 레일길이를 200m 이상으로 부설한 레일 ●장대레일화 - 차량 시동/제동하중에 의한 교축방향 수평력 작용 - 기존 : 수평력 배분을 위해 단순교로 시공(레일 이음매) - 현재 : 장대레일화 ● 장점 -유지보수비 절감 -승차감 향상(충격/소음 저감) -고속화 및 운행 안전성 향상 ●단점 -큰 레일 축력(파단/좌굴) -교량부, 급곡선부, 분기부 - 장대레일 종하중(하부구조) (중략)

  • PDF

Stability analysis of an existing utility tunnel due to the excavation of a divergence tunnel emerging from double-deck tunnel (복층터널의 분기터널 굴착에 따른 지하 공동구의 안정성 분석)

  • Nam, Kyoung-Min;Choi, Min-ki;Kim, Jung-Joo;Jafri, Turab H.;Yoo, Han-Kyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.231-248
    • /
    • 2017
  • Government plans to construct a double-deck tunnel under a portion of Gyeongbu Expressway that will solve traffic problems and could also be used as a flood storage facility. Divergence tunnels connect the main tunnel to the urban areas and their construction effects on adjacent structures at shallow depth need to be analyzed. This study primarily includes the numerical analysis of construction effects of divergence tunnels on utility tunnels. The utility tunnel was analyzed for three cases of volume loss applied to the divergence tunnel and two cases of the angle between main tunnel and divergence tunnel ($36^{\circ}$ and $45^{\circ}$). The results show that the more the volume loss was applied and the shorter the distance was between utility tunnel and divergence tunnel, the more the utility tunnel was affected in terms of induced displacements, angular displacement and stability. The worst scenario was found out to be the one where the angle between main tunnel and divergence tunnel was $36^{\circ}$ and the distance between divergence tunnel and utility tunnel was 10 m, resulting in the largest displacement and differential settlement at the bottom of the utility tunnel. A relationship between the angular displacement and the distance to diameter ratio was also established.

Numerical Analysis on the Estimation of Shock Loss for the Ventilation of Network-type Double-deck Road Tunnel (네트워크형 복층 도로터널 환기에서의 충격 손실 평가를 위한 수치해석적 연구)

  • Park, Sang Hoon;Roh, Jang Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.132-145
    • /
    • 2017
  • Shock loss was not applied for the tunnel ventilation of road tunnel in the past. However, pressure losses due to the shock loss can be significant in network double-deck road tunnel in which combining and separating road structures exist. For the optimum ventilation design of network double-deck road tunnel, this study conducted 3D CFD numerical analysis for the shock loss at the combining and separating flows. The CFD model was made with the real-scale model that was the standard section of double-deck road tunnel. The shock loss coefficient of various combining and separating angles and road width was obtained and compared to the existing design values. As a result of the comparison, the shock loss coefficient of the $30^{\circ}$ separating flow model was higher and that of the two-lane combining flow model was lower. Since the combining and separating angles and road width can be important for the design of shock loss estimation, it is considered that this study can provide the accurate design factors for the calculation of ventilation system capacity. In addition, this study conducted 3D CFD analysis in order to calculate the shock loss coefficient of both combining and separating flows at flared intersection, and the result was compared with the design values of ASHRAE. The model that was not widened at the intersection showed three times higher at the most, and the other model that was widened at the intersection resulted two times higher shock loss coefficients.

산화제 공급배관의 분기 위치에 따른 추진기관 성능 비교

  • Kim, Ji-Hoon;Lee, Han-Ju;Jung, Dong-Ho;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.179-185
    • /
    • 2005
  • It is an essential subject to decrease the mass of a launch vehicle for improving performance and efficiency of space launch system. Particularly, reducing the engine supporting area is necessary for high efficiency of propulsion system with clustered engine systems. The engine supporting area is related to the branch location of the oxidizer feeding line. This article deals the performance variation of the propulsion system such as the mass of the oxidizer feeding line, pressurization pressure of the oxidizer tank, and the onset of nucleation boiling in the oxidizer pipe with the branch location of the main feeding line.

  • PDF

Design of High-Speed 2-D State-Space Digital Filters Based on a Improved Branch-and-Bound Algorithm (개량된 분기한정법에 의한 고속연산 2차원 상태공간 디지털필터의 설계)

  • Lee Young-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1188-1195
    • /
    • 2006
  • This paper presents an efficient design method of 2-D state-space digital filter based on an improved branch-and -bound algorithm. The resultant 2-D state-space digital filters whose coefficients are represented as the sum of two power-of-two terms, are attractive for high-speed operation and simple implementation. The feasibility of the proposed method is demonstrated by several experiments. The results show that the approximation error and group delay characteristic of the resultant filters are similar to those of the digital filters which designed in the continuous coefficient space.

An Improvement on the Authoring Technology of Lecture Contents for Subjects Based on Mathematics (수학 기반 교과목 강의콘텐츠 저작기술의 개선)

  • 신운섭;오용선
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.102-106
    • /
    • 2003
  • In this paper, we propose a novel model and authoring method of digital contents which improves the educational effects in the area of cyber educations through Web. Especially we offer a new model of contents authoring for engineering departs using JAVA technology and concept-based branch strategy, making unit-contents separated in accordance with their characteristics and then accessing them at arbitrary instant in the replaying time. In proportion to the proposed model and strategy, the resultant contents might show advanced adaptabilities and interactions for users and the educational effects are really improved. Combining and realizing the proposed conceptual branch method and JAVA applet library with the conventional page-branch or subject-blanch we expect to get a novel basic scenario of engineering cyber contents and the scenario might improve the authoring and educational effects of the contents by applying its good interactive properties and realistic operations.

  • PDF

Polymeric digital optical switch with a coupling region modified for optimum mode coupling (모드 결합을 최적화 하기 위해 수정된 결합 영역을 갖는 전기광학 폴리머 디지탈 광스위치)

  • 이상신;신상영
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.245-249
    • /
    • 1997
  • An electro-optic polymer digital optical switch with a coupling region modified for optimum coupling is designed and demonstrated. Its branch waveguide is fabricated by reactive ion etching. Then, the modified coupling region is adiabatically introduced along the propagation direction from the branching point of the two waveguides, and it is implemented by photobleaching after the device fabrication. The structure of the modified coupling region and its refractive index profiles are designed to optimize and mode coupling in the Y-branch waveguide. Therefore, the switching performance of the device was shown to be enhanced with a fixed device length. The measured drive voltage is reduced by more than 30 percents, and the crosstalk is also improved by about 4~6 dB.

  • PDF

2×2 Ti:LiNbO3 optical add/drop multiplexers utilizing tilted film-loaded SAW waveguides (Tilted Film-Leaded SAW 도파로를 이용한 2×2 Ti:LiNbO3 광 삽입/분기 멀티플렉서)

  • 강창민;정흥식
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.657-662
    • /
    • 2003
  • Optimum Hamming apodized acousto-optic 2${\times}$2 add/drop multiplexers, using SiO$_2$ film loaded acoustic waveguide with angular offset to the Ti:LiNbO$_3$ waveguide, were fabricated. The four-port device consists of two input waveguides, a polarization beam splitter (PBS), two polarization conversion/acoustooptic tuning waveguide sections, a second PBS and two output waveguides. Insertion loss <7.1 ㏈ has been obtained and side-lobe of -19 ㏈ for -32 ㎽ RF driving power has been realized. Add/drop performance has been confirmed and a linear tuning rate of 8.1 nm/MHz and a 3 ㏈ spectral width of -1.5 nm were demonstrated.

A Cost-effective Control Flow Checking using Loop Detection and Prediction (루프 검출 및 예측 방법을 적용한 비용 효율적인 실시간 분기 흐름 검사 기법)

  • Kim Gunbae;Ahn Jin-Ho;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.91-102
    • /
    • 2005
  • Recently, concurrent error detection for the processor becomes important. But it imposes too much overhead to adopt concurrent error detection capability on the system. In this paper, a new approach to resolve the problems of concurrent error detection is proposed. A loop detection scheme is introduced to reduce the repetitive loop iteration and memory access. To reduce the memory overheat an offset to calculate the target address of branching node is proposed. Performance evaluation shows that the new architecture has lower memory overhead and frequency of memory access than previous works. In addition, the new architecture provides the same error coverage and requires nearly constant memory size regardless of the size of the application program. Consequently, the proposed architecture can be used as an cost effective method to detect control flow errors in the commercial on the shelf products.

Distribution of Epilithic Diatom Assemblages in an Urban Stream in Busan: Effected of Urban Climatic Conditions (도시 기후 변화가 도시하천의 부착규조류 군집에 미치는 영향)

  • Lee, Youjung;Kim, Kyungsun;Cho, Jeonggoo
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.2
    • /
    • pp.143-151
    • /
    • 2017
  • This study illustrates changes in the epilithic diatom assemblages in response to urban climatic conditions. We further assess the impact of abnormal urban climate to the urban stream environment. Epilithic diatoms, water chemical and physical variables were sampled every quarter, and assessed at 3 Oncheon stream sites, for a period of two years(from 2013~2014). The variation of physiochemical properties such as BOD, COD, T-N and T-P, show that the water quality was strongly influenced with long periods of drought and flood disturbance. Epilithic diatom assemblages were separated along the stream sites; however, the physical disturbance from urban drought and stormwater changed the composition of diatom assemblages instead of decreasing the taxonomic richness. Thus, our results suggest that epilithic diatom assemblages are altered in response to urban climatic changes, resulting in variations of stream conditions. Hence, strategies of climate change adaptation are required when considering urban stream environments.