• Title/Summary/Keyword: 분극저항

Search Result 217, Processing Time 0.022 seconds

The Study on the Corrosion Characteristics of Cr Plating in Marine Environment (해양환경 중에서 Cr도금의 부식 특성에 관한 연구)

  • 임우조;곽남인;윤병두
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.211-217
    • /
    • 2003
  • Recently, with rapid development in marine and shipbuilding industries such as marine structures, ships and chemical plants for ship, there occurs much interest in the study on corrosion characteristics played an important role in mechanical design. This paper was studies on the corrosion characteristics of chromium plating in the marine environment. Under the various specific resistance, the electrochemical polarization test of chromium plating was carried out. And thus corrosion potential, polarization resistance, corrosion current density, control efficiency of corrosion and polarization control behavior of chromium plating are investigated. The main results are as the followed : 1. The polarization resistance of Cr plating and Ni become higher than that of base metal, also and these material become low with decrease of the specific resistance. 2. As the specific resistance decreases, the corrosion current density of Cr and Ni plating is lower than that of base metal. 3. The corrosion reaction of Cr plating, Ni plating and base metal vs. specific resistance is cathodic control.

Inversion of Time-domain Induced Polarization Data by Inverse Mapping (역 사상법에 의한 시간영역 유도분극 자료의 역산)

  • Cho, In-Ky;Kim, Yeon-Jung
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.149-157
    • /
    • 2021
  • Given that induced polarization (IP) and direct current (DC) resistivity surveys are similar in terms of data acquisition, most DC resistivity systems are equipped with a time-domain IP data acquisition function. In addition, the time-domain IP data include the DC resistivity values. As such, IP and DC resistivity data are intimately linked, and the inversion of IP data is a two-step process based on DC resistivity inversions. Nevertheless, IP surveys are rarely applied, in contrast to DC resistivity surveys, as proper inversion software is unavailable. In this study, through numerical modeling and inversion experiments, we analyze the problems with the conventional inverse mapping technique used to invert time-domain IP data. Furthermore, we propose a modified inverse mapping technique that can effectively suppress inversion artifacts. The performance of the technique is confirmed through inversions applied to synthetic IP data.

Negative Induced Polarization Effects for Two-Dimensional Structures (2차원 구조에 대한 음수의 유도분극 효과)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.165-169
    • /
    • 1988
  • Negative induced polarization (IP) responses are examined for two-dimensional structures using a modeling technique with finite difference method. Percent frequency effect is used for IP parameter because it can be efficiently computed by a perturbation method. Thin conductive, polarizable overburden causes obvious negative IP responses on IP pseudosection. This fact means that IP responses from resistive, polarizable body below the overburden can be masked solely as a function of the resistivity distribution. Resistive, non-polarizable body below the overburden, however, can be detected by the negative IP responses.

  • PDF

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

A study on induced polarization characteristics of sand and clay for alluvium investigation (충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.179-184
    • /
    • 2008
  • Silt or clay alluvium fully saturated with water generally shows low resistivity. Sometimes it is believe that the low resistivity layer is considered as good aquifer but this makes problems in the development of groundwater. To overcome this problem, we adopted induced-polarization(IP) method with resistivity method. Laboratory experiments and resistivity/IP field surveys with non-polarization electrodes were conducted for the study. Laboratory experiments shows that the increase of clay contents in the sample mixed with sand and clay give low resistivity and high chargeability. We used this experiment results in the interpretation of resistivity/IP field data which were obtained in riverbank filtration. Finally, the layer which has low resistivity and chargeabilty would be regarded as a good aquifer for the development of groundwater intake.

  • PDF

Improvement of Precision in Ferroelectric Polarization Hysteresis Measurement (강유전체 분극 이력곡선의 측정 정밀도 향상)

  • Jae Hwan Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.51-55
    • /
    • 2023
  • Measurement of the ferroelectric polarization hysteresis curve is an important means of overall evaluation and interpretation of the ferroelectric structure and dielectric properties. If a resistive component is included in the ferroelectric sample, an error is included in the measured value of the spontaneous polarization. When configuring the electrical circuit to measure the polarization, by properly utilizing the external resistance corresponding to the resistive component included in the sample, the error due to the resistive loss of the sample was excluded and the size of the ferroelectric polarization induced inside could be accurately measured. It is expected that the displacement and dielectric characteristics of ions inside the ferroelectric can be more accurately evaluated through the evaluation of such an accurate polarization hysteresis curve.

Corrosion resistance of gallium-doped zinc oxide film depending on the hydrogen content (수소가스 함유량에 따른 Gallium-doped Zinc Oxide(GZO) 박막의 내식성 평가)

  • Jo, Su-Ho;Choe, In-Gyu;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.188-188
    • /
    • 2016
  • GZO 박막은 상업적으로 사용되는 ITO를 경제적으로 대체할 수 있는 유망한 투명 전도 물질이며, 인체에 무해하고, 공급이 쉬우며, 화학적으로 안정하다. 특히, CIGS와 같은 광전변환 소자 전극에서는 부식 저항이 매우 중요한데, 습한 환경에서 견뎌낼 수 있다는 장점이 있다. GZO는 3가 갈륨이 2가 아연에 도핑된 n타입의 반도체 물질이다. 그리고 육각형의 황화아연 물질의 전기 전도도는 산소 결핍에 매우 의존한다. GZO의 수소는 산소 결핍 집중에 영향을 끼친다. 따라서 이 연구에서는 RF 마그네트론 스퍼터링 실험 동안 수소 함유량을 다양화 시키고, 면 저항, 광 투과도, 부식저항의 효과를 조사한다. 수소량이 증가할수록, 면 저항은 향상되어지고, 특정 지점을 넘으면 감소한다. 분극 실험에 의해 측정되어진 부식 저항은 박막의 미세조직과 결정립계의 특성에 더 의존되어진다. 훨씬 더 많은 수소를 함량한 비정질이 부식 저항성에 있어서 유효한 차이를 나타내지 못하는 동안 결정 내에서 많은 수소를 지닌 작은 결정의 결정립계는 낮은 분극저항, 즉 낮은 부식 저항성의 결과를 도출한다.

  • PDF

Effect of YSZ Particle Size and Sintering Temperature on the Microstructure and Impedance Property of Ni-YSZ Anode for Solid Oxide Fuel Cell (고체산화물 연료전지용 Ni-YSZ 음극의 미세구조와 임피던스특성에 미치는 YSZ 입자크기 및 소결온도의 영향)

  • 김구대;문지웅;이기태;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.466-473
    • /
    • 2001
  • Ni-YSZ 음극의 미세구조와 임피던스특성에 미치는 YSZ 입자크기 및 소결온도의 영향을 고찰하였다. 0.3~0.6$\mu\textrm{m}$의 미세한 NiO 분말을 사용할 경우에는 NiO 분말과 크기가 비슷한 미세한 YSZ 분말(TZ8Y, 0.3$\mu\textrm{m}$)을 첨가했을 때 NiO의 입성장을 억제하는 효과가 가장 크고 환원후 Ni의 입자크기를 미세하게 유지할 수 있는 미세구조를 형성하였다. 또한 미세한 YSZ 분말 (TZ8Y, 0.3$\mu\textrm{m}$)과 조대한 YSZ 분말(FYT13.0, 2$\mu\textrm{m}$)의 혼합비를 달리하여 후막을 제조하였을 때에 TZ8Y 분말만 첨가한 조성이 가장 낮은 분극 저항을 나타내었다. 한편 소결온도는 삼상계면의 양과 분극저항에 영향을 주었으며, 140$0^{\circ}C$에서 소결한 시편의 분극저항이 가장 낮은 값을 나타내었다.

  • PDF

원전 중기발생기 전열관 합금의 국부 부식 저항성에 미치는 합금 원소 및 부식 조건의 영향

  • 엄태식;박용수;김영식;정한섭;국일현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.117-122
    • /
    • 1996
  • 본 연구에서는 2개사에서 제조된 합금 600 및 합금 690 이음매 없는 관과 진공 유도 용해로 제조한 합금 690 판재에 대하여 부시 환경의 변화에 따른 특성 평가를 행하였다. 부식 평가는 양극 분극 시험을 통하여 행하였으며 부식 환경은 NaCl, HCl, NaOH(+$Na_2$SO$_4$) 용액 및 Cu$^{+}$/Cl$^{-}$ SO$_4$$^{2-}$ 용액이었다. 합금 600 및 합금 690의 양극 분극 저항성을 부식 환경에 따라 평가한 결과, 부식 용액의 종류에 따라 서로 다른 분극 거동을 보이고 있으며, 합금 690의 저항성이 합금 600의 저항성보다 우수하게 나타났다. 또한 가성 용액 중에 $Na_2$SO$_4$를 첨가할 경우 부식 속도를 가속화시키고 있다. 한편 Mo이 첨가되지 않은 합금 690M0의 경우는 Cl$^{-}$ SO$_4$$^{2-}$ 비가 증가할수록 공식 저항성이 급격히 감소하고 있으나, Mo이 첨가된 합금 690M2의 경우는 시험한 전체 비율에서 이온의 영향을 받지 않는 것으로 나타나고 있어 합금 690의 공식 저항성에 Mo이 매우 좋은 효과를 보이고 있음을 알 수 있다.

  • PDF

Oxygen Reduction Mechanism and Electrode Properties of (La,Sr)$MnO_3$-YSZ Composite Cathode for Solid Oxide Fuel Cell (Part II: Electrode Properties) (고체산화물 연료전지용 (La,Sr)$MnO_3$-YSZ 복합체 양극의 산소환원 반응기구 및 전극 특성 (Part II: 전극 특성))

  • 김재동;김구대;이기태
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • (La,Sr)MnO$_3$(LSM)-YSZ 복합체 양극에 있어서 소결온도 및 전극두께와 cathodic potential이 전극 특성에 미치는 영향을 고찰하였다. 양극의 소결은 삼상계면의 양을 결정하는 중요한 변수로 LSM 단미 양극과 YSZ가 40 wt% 포함된 LSM-YSZ 복합체 양극 모두 120$0^{\circ}C$에 소결했을 때 가장 낮은 분극저항을 나타내었다. 또한 양극 후막의 두께가 얇아지면 양극의 in-plane 저항이 증가하여 ohmic 저항이 증가하였는데, LSM-YSZ 복합체 양극의 경우 약 30$mu extrm{m}$ 정도의 전극두께가 가장 효과적인 전극 특성을 나타내었다. 한편, LSM-YSZ 복합체 양극에 -0.5 V의 cathodic potential을 인가함에 따라 양극에서 일어나는 산소환원반응의 활성이 증가하였는데, 1가 산소이온의 표면확산반응의 분극저항은 감소하였으나, 고주파수 영역에서 나타나는 산소이온전달반응의 저항은 거의 변화하지 않았다. 이것은 Mn의 환원에 의한 양극표면에 생성된 산소공공에 기인한다.

  • PDF