• Title/Summary/Keyword: 부하전류 측정

Search Result 193, Processing Time 0.04 seconds

HEMP Effect Analysis for Equipment Using Comparison of Norms between HEMP Filter Residual Current and Conducted Susceptibility Criteria (HEMP 필터 잔류 전류와 전도 내성 기준의 특성인자 비교를 통한 장비의 HEMP 영향성 분석)

  • Kwon, Joon-Hyuck;Song, Ki-Hwan;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.199-207
    • /
    • 2014
  • Although High-altitude electromagnetic pulse(HEMP) protection filter meets the requirements of pulsed current injection(PCI) acceptance test, the equipment under test which has low electromagnetic susceptibility level can be damaged during PCI verification test that is performed on operating condition of equipment. This paper proposed the HEMP effect analysis method using comparison of norms between residual current of HEMP filter and transient electromagnetic conducted susceptibility criteria of equipment, as an alternative method under the condition that performing PCI verification test is limited in HEMP hardened facilities. PCI acceptance test of HEMP filter, transient electromagnetic conducted susceptibility test, and PCI verification test are performed and test results are analyzed.

Design and Evaluation of stand alone PV Power system for the residential application (독립형 주택용 태양광 발전시스템의 설계 및 운전평가)

  • Ahn, Kyo-Sang;Seo, Hai-Kyung;Lim, Hee-Chun;Kim, Sin-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.352-354
    • /
    • 2003
  • 본 논문에서는 상용전력 계통이 어떠한 이유에 의하여 전력공급이 중단 되었을 때 최소의 전력공급을 위하여 독립형 시스템과 연계형 시스템을 일체화한 독립 연계형 겸용시스템의 적용 가능성을 도출하기 위하여, 설계.제작 하였다. 독립모드에서 부하는 저항부하를 사용하였으며, 300W, 600W, 900W, 1,200W의 부하시 전력품질을 측정하였으며. 1,200W의 부하시에 전압/전류 외율은 5.23% / 5.41%로 부하에 따라 변화하였으며, 연계형 시스템과 달리 전압 왜율이 부하증가에 따라 증가하는 특성을 보여 주었다.

  • PDF

Research on problem the method of calculating the utilization coefficent of a polmounted TR (주상변압기 이용율 계산방법에 대한 문제점 연구)

  • Lee, Won-Jung;Won, Tai-Seung;Chio, Moon-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.392-393
    • /
    • 2008
  • 한전에서는 배전용 변압기의 부하관리를 위하여 전국사업소에 산재해 있는 변압기를 NDIS1) 부하관리 시스템으로 데이터 베이스화 하고, 각 변대에 수용되어 있는 고객의 월별 전기사용량을 추출하기 위하여 영업정보시스템과 연계하여 변압기, 배전선 개체관리는 물론 부하계산, 부하실적 및 부하예측 자료를 관리하고 있다. 이중 전등부하는 고객의 월간 사용전력량(kWh)과 최대부하(kVA)의 부하특성에 따른 상관 계수를 산정하여 이를 상관식에 적용하여 최대부하를 산출하고 있으며, 동력부하는 계약전력 및 종합수용률을 적용하여 부하전류를 계산하고 있으나 최근 고객의 냉방부하 급증으로 인하여 고객의 계약전력과 실제 설비용량과의 많은 차이가 발생하고 있어 변압기 관리에 어려움이 있고, 과부하로 인하여 변압기가 소손되는 사례도 발생하고 있다. 따라서 변압기 무선부하 감시시스템으로 측정한 결과를 토대로 변압기 이용율 계산의 정확도를 높이고 변압기 관리를 효율적으로 할 필요가 있다.

  • PDF

A Study on the Passive Filter Control System to reduce harmonic of DC Motor drives (직류전동기 구동장치의 고조파 저감을 위한 수동필터 제어시스템 연구)

  • Lee Sang Ick;Yoo Jae Geun;Jeon Jeong Chay
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.280-282
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 $개\cdot폐$할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 $개\cdot폐$ 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 $개\cdot폐$하게된다. 이러한 제어시스템은 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 고조파 및 무효전력등을 측정함으로써 성능을 입증하였다.

  • PDF

A Study on Load Current and Temperature to Expect Lifetime of High-Power Cables (고전력 케이블의 잔여 수명 예측을 위한 부하 전류 및 온도 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.199-203
    • /
    • 2015
  • With the development of industry these days, the demand for electric power increases and the larger capacity for power transfer is required. The scales of facilities should become larger; and the relative systems are required to operate with a higher degree of reliability. Therefore, stabilization of electric power systems is an important issue. The high degree of reliability required in the process of production and supply of electric power is an essential part of industrial society. Accident such as blackouts causes a hugh amount of economic losses to the high-tech industrial society dependent upon electric power. This paper is about the basic study of the relations between the load current and lifetime of power cables in operation. In order to do the research, we installed a current transformer and an equipment for measuring temperature at the 6.6. kV cables in operation. The two equipments have been installed on the cable systems in operation for the last 20 years. Since the insulation resistance of most of the cables showed the value larger than the threshold, it was not easy to tell the remaining lifetime of cables. The load current of the cables was almost constant. The surrunding temperature was $15{\sim}25^{\circ}C$, little variation of temperature values.

Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower (345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.14-21
    • /
    • 1998
  • In this paper, the measurements of ELF electric and magnetic fields due to double circuit 345[kV} transmission lines are made using planar-type electric field sensor and multitum loop-type magnetic field sensor, and the magnitudes of electric and magnetic fields are illustrated by a three-dimensional plot. Also, in order to predict the magnetic field strength with lad variation, a typical daily load current curves of the transmission lines are displayed because the magnetic field is changed with load current. experimental results of ELF electric and magnetic fields along center line versus lateral distance are compared with the theoretical values computed by using the FIELDS program. The electric field intensity in and around a transmission tower is lowered, and the greatest point of the magnetic field is shifted to the heavy load line but generally is given the trend that the peak value appear at the central part of the transmission tower. The magnitudes of the maximum electric and magnetic fields in the vicinity of a transmission tower are less than 3.5[kV/m] and $20[{\mu}T]$, respectively. The measured electric and magnetic fields are satisfied with limits and guidelines recommended by various authorized international institutes.

  • PDF

A MTPA Control of PMSMs Using an Optimization Method (최적화 기법을 이용한 PMSM의 MTPA 제어)

  • Kim, Do-Hyun;Park, Seung-Chan;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.439-440
    • /
    • 2020
  • 본 논문에서는 PMSM(Permanent Magnet Synchronous Motor)의 구동 효율 향상을 위한 MTPA(Maximum Torque Per Ampere) 제어 기법에 대해 제안한다. 제안된 기법은 전동기의 동손이 최소가 되도록 최적화 기법을 통해 전류각 지령을 조정한다. 제안된 기법을 통해 모든 부하 조건에서 짧은 시간 내에 동손이 최소가 되는 최적 전류각을 추종할 수 있으며, 전동기의 제정수 혹은 위치 측정 오차에 강인하다. 800W IPMSM 구동 실험을 통해 제안된 기법의 효용성을 검증하였다.

  • PDF

Study on the High Temperature Superconductor for applying resistive Superconducting Fault Current Limiter (저항형 초전도 한류기 적용을 위한 다양한 고온 초전도 선재의 특성 연구)

  • Na, Jin-Bae;Jang, Jae-Young;Hwang, Young-Jin;Kang, Hyoung-Ku;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1013-1014
    • /
    • 2011
  • 급격한 산업 발전으로 전려계통의 수요 증가가 꾸준히 증가하고 있으며, 2007년부터 2020년까지 매년 2.2%씩 증가할 것으로 예상된다. 전력계통의 증대로 고장전류의 크기도 더불어 증가하고 있으며 이는 기존의 차단의 부하 용량을 넘어서고 있다. 따라서 안정적이고 효율적인 고장전류 차단을 위해서 초전도 한류기의 필요성이 대두되고 있다. 본 연구는 다양한 초전도 한류기 중에서 순수 저항형 초전도 한류기의 적용 가능한 2세대 고온 초전도 선재들의 특성을 파악하였다. 현재 상용화가 이루어지고 있는 2세대 고온 초전도 선재의 동작 온도에 따른 온도별 비저항, 임계전류, 교류 손실과 단위 길이당 인가 허영 전기장을 을 측정하였다. 상위 과정을 통해서 측정된 각 선재별 특성을 바탕으로 초전도 저항형 한류기에 적용 가능한 선재를 제안하고자 한다.

  • PDF

The analysis of the effects for the various fault location on the distribution lines (배전 선로에서 고장 위치에 따른 영향 분석)

  • Kim, Min-Seok;Lim, Kyong-Sub;Seong, No-Kyu;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2223_2224
    • /
    • 2009
  • 현대 사회에서의 배전은 단순히 전력 공급에서 그치는 것이 아니라, 우수한 전력 품질을 지닌 전기를 공급해 주는 것에 큰 의미를 두고 있다. 배전 선로에서 고장이 발생할 경우 서로 유기적인 연관성 및 부하의 밀집도가 큰 배전계통의 특성상 전력품질저하 및 고장파급효과가 매우 크다. 전력품질은 일정한 주파수 및 전류, 전압 등을 기반으로 하며 고장에 의해 이러한 요소들이 영향을 받아 전력품질 저하의 원인이 된다. 따라서 배전계통에서의 고장에 의한 영향을 자세히 분석하기 위해 EMTP(ElectroMagnetic Transients Program)를 이용하여 고장을 모의하고 결과를 분석하였다. 다양한 유형의 조건을 모의하기 위해 계통의 여러 위치에서 1선지락 고장을 모의하였고, 각 고장 지점에 따라 다양한 위치에서 전압과 전류를 측정하여 고장의 파급효과를 측정하여 고장 발생 시 전압과 전류의 관계 및 거리에 따른 고장파급효과를 분석하였다.

  • PDF

Detecting the air-gap flux of the stator fault in induction motor (고정자 권선 단락 시 유도전동기 공극자속 검출)

  • Son, Dong-Hyeok;Kim, Byong-Kuk;Hwang, Don-Ha;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.968-969
    • /
    • 2008
  • 본 논문에서는 유도전동기에서 발생되는 고장들 중에서 고정자 권선 단락 고장 특성 해석과 고장 판별에 대한 방법을 제시한다. 고정자 권선 단락을 판별하기 위해서 단락상태의 고정자를 모델링하여 3상 전류 불평형과 공극자속밀도에 대한 유한요소해석을 수행하였다. 유한요소해석으로 얻어진 결과의 타당성을 입증하기 위해 실험을 통하여 전류와 공극자속에 대한 유기기전력 측정값을 비교하였다. 공극자속의 유기기전력을 측정하기 위해 고정자 슬롯에 자속센서를 취부하였다. 고정자 권선 단락 시 3상 전류는 불평형을 이루고 공극자속밀도가 감소되어 유도전동기의 고정자 고장을 판별하는 기초자료가 된다.

  • PDF