• Title/Summary/Keyword: 부피성

Search Result 1,688, Processing Time 0.026 seconds

Quality Stability of Oleoresin Onion (양파 Oleoresin의 저장중 품질 변화)

  • 최옥수;배태진
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 1998
  • As a way of mass process of onion, Allium cepa L., the oleoresin decompressed and concentrated is an alternative process to minimize lowering in the quality of onion during storage, to improve the original flavor and taste, and to increase variety as processing aids. This study was performed to investigate on the quality stability during storage of oleoresin. Oleoresin product was manufactured by mixing a concentration of onion juice and ethanol extract homogenously, emulsified by an additional 2% PGDR(polyglycerol condensed ricinoleate) and 1% cysteine. During 60 days storage at 5$^{\circ}C$, $25^{\circ}C$ and 4$0^{\circ}C$ the total sugar content in oleoresin product was very stable, and absorbances at 420nm as browning reaction index were 0.38, 1.53 and 3.32, respectively, addition of 1% cysteine retarded the browning reaction effectively. When oleoresin product was centrifuged(2000$\times$G, 60 minutes), the volumes of emulsion level without separation were 96.8%, 94.1% and 9.06%, respectively during 20 days, 40 days and 60 days storage at 5$^{\circ}C$, and those during 60 days storage at $25^{\circ}C$ and 4$0^{\circ}C$ were appeared to be 83.2% and 75.4%. Showing lower level as increasing storage temperature. Antioxidant indexes(AI) of soybean oil added 1% oleoresin without storage and 0.02% BHA were 1.39 and 1.72. The former showed 80.8% antioxidant activity on induction time extension effect of the latter. Antioxidant indexes of oleoresin decreased slightly as increasing storage temperature and were 1.37, 1.30 and 1.08. Total pyruvate contents were 89.9%, 79.7% and 65.2%, respectively during 60 days storage at 5$^{\circ}C$, $25^{\circ}C$ and 4$0^{\circ}C$. Rate constant, Q10 value and activation energy were 1.381~4.735 mmol/$\ell$.hr, 1.537~1.694 and 11.649 ㎉/g mole for the reduction of pyruvates in the range of storage temperatures during oleoresin storage.

  • PDF

Flexural Properties according to Change of Polymerization Temperature of Autopolymerized Resin for Orthodontic (치과 교정용 자가중합형 Resin의 중합 온도 변화에 따른 굽힘 특성)

  • Lee, Gyu Sun
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.259-264
    • /
    • 2015
  • For this experiment, specimen was manufactured by injecting polymer and monomer into silicon mold with volume ratio of 2.5:1 based on ISO 20795-2 so that average thickness, width and length of specimen would be maintained as 3.3 mm, 10.0 mm and 65.0 mm, respectively depending on spray on technique. Specimen was divided into 3 groups ($25^{\circ}C$, $40^{\circ}C$, $70^{\circ}C$) depending on polymerization temperature and 10 specimen was manufactured for each group and it was polymerized in water tank of ${\pm}1^{\circ}C$ under the setting condition of polymerization time of 15 minutes and pressure of 3 bar. After keeping specimen in distilled water of $37^{\circ}C$ for over 48 hours before experiment, flexural strength (FS) and elasticity modulus (EM) of specimen being tested by using Intron (3344; Instron; Instron). SPSS ver. 16.0 was used for analysis and post-hoc test of Scheffe was performed after using one-way ANOVA. When comparing mean value of FS of resin for orthodontics, it was represented in the range of 71.500 MPa for $25^{\circ}C$ group, 74.920 MPa for $40^{\circ}C$ group and 76.880 MPa for $70^{\circ}C$ group and difference was shown in the order of $25^{\circ}C$ group <$40^{\circ}C$ group <$70^{\circ}C$ group but such difference was not significant statistically (p=0.052). Result of EM mean value of resin for orthodontics was more polymerization temperature was high, the more was significant difference represented in the order of $25^{\circ}C$ group <$40^{\circ}C$ group <$70^{\circ}C$ group (p<0.039).

Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers (폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교)

  • Chai, Gyu-Young;Lim, Young-Kyung;Kang, Ki-Mun;Jeong, Bae-Gwon;Ha, In-Bong;Park, Kyung-Bum;Jung, Jin-Myung;Kim, Dong-Wook
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.238-248
    • /
    • 2010
  • Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.

Properties of Dietary Fiber Extract from Rice Bran and Application in Bread-making (미강에서 추출한 식이섬유추출물의 특성 및 제빵에의 응용)

  • Kim, Young-Soo;Ha, Tae-Youl;Lee, Sang-Hyo;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.502-508
    • /
    • 1997
  • Rice bran dietary fiber extract, which was obtained after termamyl treatment of defatted rice bran contained $27.3{\sim}30.5%$ protein, $49.7{\sim}54.1%$ insoluble dietary fiber, and $1.9{\sim}2.7%$ soluble dietary fiber. Extrusion decreased the insoluble dietary fiber content but increased the soluble dietary fiber content, while roasting did not. Influence those content. Each mineral element content was depended upon heat processing method. Extrusion increased the water binding capacity and L value, while roasting reduced the water binding capacity and L value. Scanning electron microscopy showed damaged cell walls for extruded sample compared to roasted one which had fully collapsed cell walls. The increase of water absorption, developing time, and stability and the of MTI of wheat flour-dietary fiber extract composites with addition of dietary fiber extract were observed by Farinograph. Rice bran dietary fiber extract had an effect on the bread making resulting in increase of bread weight and color of crumb and crust, and decrease of bread volume and texture. As a result of sensory evaluation, appearance, texture, overall acceptability were significantly different from control but flavor and taste were not different significantly up to 6% level. Heat treated samples had differences in mean values, but not significant differences statistically.

  • PDF

Quality Characteristics of Instant Rice Noodles Manufactured with Broken Rice Flour (파쇄미 쌀가루를 이용한 즉석 쌀국수의 품질특성)

  • Choi, Eun-Ji;Kim, Chang-Hee;Kim, Young-Boong;Kum, Jun-Seok;Jeong, Yoonhwa;Park, Jong-Dae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.8
    • /
    • pp.1270-1277
    • /
    • 2014
  • This study investigated the quality characteristics of instant rice noodles manufactured with broken rice flour as an application of rice-processed products. We examined the physicochemical characteristics of common rice flour (CRF), broken rice flour (BRF), and CRF mixed with BRF (CBRF). Futhermore, instant rice noodles were manufactured with these three types of rice flour, and their quality and sensory characteristics were also investigated. Damaged starch content and water-binding capacity of rice flour were highest in BRF. Particle size of rice flour was significantly different among the three types. RVA pasting viscosities of BRF and CBRF were higher than that of CRF. Volume after cooking of instant rice noodles increased in rice noodles made with broken rice flour (BRN). Turbidity and cooking loss of BRN were higher than those of common rice noodles (CON). For texture properties, CON displayed the highest hardness, adhesiveness, and chewiness. In the sensory evaluation, springiness and overall acceptability values of CON were significantly higher than those of other rice noodle types (BRN and CBRN). In conclusion, BRN showed increased cooking loss and turbidity with reduced texture and overall acceptability values. The results of this study suggest that added amount of CRF may significantly increase the overall quality of instant rice noodles prepared with BRF.

Development of a TBM Advance Rate Model and Its Field Application Based on Full-Scale Shield TBM Tunneling Tests in 70 MPa of Artificial Rock Mass (70 MPa급 인공암반 내 실대형 쉴드TBM 굴진실험을 통한 굴진율 모델 및 활용방안 제안)

  • Kim, Jungjoo;Kim, Kyoungyul;Ryu, Heehwan;Hwan, Jung Ju;Hong, Sungyun;Jo, Seonah;Bae, Dusan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • The use of cable tunnels for electric power transmission as well as their construction in difficult conditions such as in subsea terrains and large overburden areas has increased. So, in order to efficiently operate the small diameter shield TBM (Tunnel Boring Machine), the estimation of advance rate and development of a design model is necessary. However, due to limited scope of survey and face mapping, it is very difficult to match the rock mass characteristics and TBM operational data in order to achieve their mutual relationships and to develop an advance rate model. Also, the working mechanism of previously utilized linear cutting machine is slightly different than the real excavation mechanism owing to the penetration of a number of disc cutters taking place at the same time in the rock mass in conjunction with rotation of the cutterhead. So, in order to suggest the advance rate and machine design models for small diameter TBMs, an EPB (Earth Pressure Balance) shield TBM having 3.54 m diameter cutterhead was manufactured and 19 cases of full-scale tunneling tests were performed each in 87.5 ㎥ volume of artificial rock mass. The relationships between advance rate and machine data were effectively analyzed by performing the tests in homogeneous rock mass with 70 MPa uniaxial compressive strength according to the TBM operational parameters such as thrust force and RPM of cutterhead. The utilization of the recorded penetration depth and torque values in the development of models is more accurate and realistic since they were derived through real excavation mechanism. The relationships between normal force on single disc cutter and penetration depth as well as between normal force and rolling force were suggested in this study. The prediction of advance rate and design of TBM can be performed in rock mass having 70 MPa strength using these relationships. An effort was made to improve the application of the developed model by applying the FPI (Field Penetration Index) concept which can overcome the limitation of 100% RQD (Rock Quality Designation) in artificial rock mass.

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Improvement of Fluid Penetration Efficiency in Soil Using Plasma Blasting (플라즈마 발파를 이용한 토양 내 유체의 침투 효율 개선)

  • Baek, In-Joon;Jang, Hyun-Shic;Song, Jae-Yong;Lee, Geun-Chun;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.433-445
    • /
    • 2021
  • Plasma blasting by high voltage arc discharge were performed in laboratory-scale soil samples to investigate the fluid penetration efficiency. A plasma blasting device with a large-capacity capacitor and columnar soil samples with a diameter of 80 cm and a height of 60 cm were prepared. Columnar soil samples consist of seven A-samples mixed with sand and silt by ratio of 7:3 and three B-samples by ratio of 9:1. When fluid was injected into A-sample by pressure without plasma blasting, fluid penetrated into soil only near around the borehole, and penetration area ratio was less than 5%. Fluid was injected by plasma blasting with three different discharge energies of 1 kJ, 4 kJ and 9 kJ. When plasma blasting was performed once in the A-samples, penetration area ratios of the fluid were 16-25%. Penetration area ratios were 30-48% when blastings were executed five times consecutively. The largest penetration area by plasma blasting was 9.6 times larger than that by fluid injection by pressure. This indicates that the higher discharge energy of plasma blasting and the more numbers of blasting are, the larger are fluid penetration areas. When five consecutive plasma blasting were carried out in B-sample, fluid penetration area ratios were 33-59%. Penetration areas into B-samples were 1.1-1.4 times larger than those in A-samples when test conditions were the same, indicating that the higher permeability of soil is, the larger is fluid penetration area. The fluid penetration radius was calculated to figure out fluid penetration volume. When the fluid was injected by pressure, the penetration radius was 9 cm. Whereas, the penetration radius was 27-30 cm when blasting were performed 5 times with energy of 9 kJ. The radius increased up to 333% by plasma blasting. All these results indicate that cleaning agent penetrates further and remediation efficiency of contaminated soil will be improved if plasma blasting technology is applied to in situ cleaning of contaminated soil with low permeability.

Seedling Quality, and Early Growth and Fruit Productivity after Transplanting of Squash as Affected by Plug Cell Size and Seedling Raising Period (플러그 셀 크기와 육묘일수에 따른 애호박의 묘 소질, 정식 후 초기 생육 및 과실 생산성)

  • Kim, Yeong Sook;Park, Yoo Gyeong;Jeong, Byoung Ryong
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.185-196
    • /
    • 2019
  • Abstract. This research was conducted to figure out the optimal size of the plug cell and seedling raising period in 'Nongwoo' and 'Nonghyeop' cultivars. In the first experiment on effect of plug cell size on growth of squash, seedlings were transplanted into hydroponic cultivation beds at different growing stages: Those in 32-cell trays with 3-4 true leaves at 25 days after sowing, those in 50-cell trays with 2 true leaves at 15 days after sowing, those in 105-cell trays just before a true leaf development, and those in 162-cell trays with only cotyledons at 8 days after sowing. In the second experiment on effect of seedling raising period on growth of squash, it was conducted to have different sowing dates. But the same transplanting date, based on the results of Experiment 1, and compared the differences in growth and fruit productivity as affected by plug cell size in the same way with experiment 1 including the cultivars and environmental conditions. After setting the transplanting date in advance, the number of days for sowing were calculated back for each treatment. In the first experiment, plant height was the greatest in 105-cell trays followed by 162, 50 and 32-cell trays in both cultivars. The best fruit quality was found in different treatments depending on the cultivars, although it was the lowest in 32-cell trays in both cultivars. The fruit quality was not significantly different among those from cell sizes. Therefore, when raising seedlings in 105-cell trays, the period of raising seedlings can be shortened as compared with the conventional 32-cell trays, and this change could reduce the workforce required for growing and transplanting seedlings. In the second experiment, after transplanting, shoot height and leaf width in the first measurement in both cultivars were greater in the 32-cell treatment. However, the last measurement after four weeks showed no significant difference in plant height, but significantly greatest leaf width in the smallest cell treatment, even as compared with that in 32-cell treatment. In case of 'Nongwoo', length and weight of the first harvested fruit showed the highest values in the treatment of 105-cell trays. In case of 'Nonghyeop' the 162-cell treatment along with the 105-cell treatment showed greatest length and weight of the first fruits. From these results, zucchini plug seedlings can be raised in plug trays with reduced cell sizes than the conventional 32-cell trays with improved fruit productivity.

In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods (제작방법에 따른 임시 수복용 레진의 마모저항성에 관한 연구)

  • Ahn, Jong-Ju;Huh, Jung-Bo;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.110-117
    • /
    • 2019
  • Purpose: This study was to evaluate the wear resistance of 3D printed, milled, and conventionally cured provisional resin materials. Materials and methods: Four types of resin materials made with different methods were examined: Stereolithography apparatus (SLA) 3D printed resin (S3P), digital light processing (DLP) 3D printed resin (D3P), milled resin (MIL), conventionally self-cured resin (CON). In the 3D printed resin specimens, the build orientation and layer thickness were set to $0^{\circ}$ and $100{\mu}m$, respectively. The specimens were tested in a 2-axis chewing simulator with the steatite as the antagonist under thermocycling condition (5 kg, 30,000 cycles, 0.8 Hz, $5^{\circ}C/55^{\circ}C$). Wear losses of the specimens were calculated using CAD software and scanning electron microscope (SEM) was used to investigate wear surface of the specimens. Statistical significance was determined using One-way ANOVA and Dunnett T3 analysis (${\alpha}=.05$). Results: Wear losses of the S3P, D3P, and MIL groups significantly smaller than those of the CON group (P < .05). There was no significant difference among S3P, D3P, and MIL group (P > .05). In the SEM observations, in the S3P and D3P groups, vertical cracks were observed in the sliding direction of the antagonist. In the MIL group, there was an overall uniform wear surface, whereas in the CON group, a distinct wear track and numerous bubbles were observed. Conclusion: Within the limits of this study, provisional resin materials made with 3D printing show adequate wear resistance for applications in dentistry.