• Title/Summary/Keyword: 부피성

Search Result 1,688, Processing Time 0.03 seconds

Effects of Organic Acids on Textural Properties and Storage Stabilities of Long Life Noodles (유기산의 첨가에 따른 Long Life 면의 조직감과 저장 안정성)

  • Jeong, Jae-Hong
    • Journal of the Korean Society of Food Culture
    • /
    • v.13 no.3
    • /
    • pp.191-196
    • /
    • 1998
  • The influence of organic acid dips on the quality properties, color, cooking quality, textural and sensory properties, and reducing microbial population of LL(Long Life) noodles was studied. The contents of organic acid used were 0.2% based on flour weight and LL noodles were treated by dipping in pH $2.5{\pm}0.1$ for $60{\sim}90sec$. The whiteness of LL noodles treated with dl-malic acid was higher than that of others. The shear extrusion force and hardness of LL noodles treated with dl-malic acid were shown much higher value than those of others except treated with dl-malic acid. acetic acid(=1:1). At cooking quality examination of LL noodles treated with organic acids, weight of cooked LL noodles treated with dl-malic acid was decrease but volume was appeared in vice versa. Extraction amounts of LL noodles treated with dl-malic acid, dl-malic acid : acetic acid(=1:1) during cooking were much smaller than those of others. Total counts of microorganism of LL noodles treated with dl-malic acid,dl-malic acid. acetic acid(=1:1) were disappeared during storage at $30^{\circ}C$ but treated with latic acid, acetic acid were increase during storage. Sensory properties of cooked LL noodles which was treated with dl-malic acid showed quite acceptable.

  • PDF

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

Trichloroethylene Treatment by Zero-Valent Iron and Ferrous Iron with Iron-Reducing Bacteria - Model Development (영가철 및 철환원균을 이용한 2가 산화철 매질에 의한 TCE 제거 연구 - 모델수립)

  • Bae, Yeun-Ook;Kim, Doo-Il;Park, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1146-1153
    • /
    • 2008
  • Numerical simulation was carried out to study the trichloroethylene (TCE) degradation by permeable reactive barrier (PRB), and revealed the effect of concentration of TCE, iron medium mass, and concentration of iron-reducing bacteria (IRB). Newly developed model was based on axial dispersion reactor model with chemical and biological reaction terms and was implemented using MATLAB ver R2006A for the numerical solutions of dispersion, convection, and reactions over column length and elapsed time. The reaction terms include reactions of TCE degradation by zero-valent iron (ZVI, Fe$^0$) and ferrous iron (Fe$^{2+}$). TCE concentration in the column inlet was maintained as 10 mg/L. Equation for Fe$^0$ degradation includes only TCE reaction term, while one for Fe$^{2+}$ has chemical and biological reaction terms with TCE and IRB, respectively. Two coupled equations eventually modeled the change of TCE concentration in a column. At Fe$^0$ column, TCE degradation rate was found to be more than 99% from 60 hours to 235 hours, and declined to less than 1% in 1,365 hours. At the Fe$^{2+}$ and IRB mixed column, TCE degradation rate was equilibrated at 85.3% after 210 hours and kept it constant. These results imply that the ferrous iron produced by IRB has lowered the TCE degradation efficiency than ZVI but it can have higher longevity.http://kci.go.kr/kciportal/ci/contents/ciConnReprerSearchPopup.kci#

Retention Behaviors of Natural Gas Components on a Single Column by Gas Chromatography (기체 크로마토그래피에 의한 단일 컬럼상에서 천연가스 성분의 머무름 거동)

  • Choi, Yong-Wook;Choe, Kun-Hyung;Lee, Dai-Woon
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.329-338
    • /
    • 1994
  • The retention behaviors of natural gas components were studied on a single column by gas chromatography. The dead time, $t_0$ was obtained by using extrapolation of homologous series to determine capacity factors. The plots of retention data for homologous series and carbon number at different temperatures were shown to converge into a single point, which point was determined as a dead time. The results of the effect of temperature on the column efficiency for n-butane exhibited the plate number, N incerased with temperature, but the resolution among the fast eluted components decreased. The adsorption enthalpy (${\Delta}H^0{_{ads}}$) for each component on 28% DC 200 stationary phase was determined, and in order to investigate the retention behaviors of natural gas components the regression analysis of log $t_R$, log k' and log ${\alpha}$ vs. van der Waals volume(Vw), molecular connectivity index(X) and hydrophobic fragmental constant(f) were carred out. Good correlation was found between log k' vs. Vw, and log k' vs. f. The correlations between the physical properties of natural gas and the physical parameters were investigated by the linear regression analysis. The relationships between Vw vs. molecular weight and heating value(${\Delta}H_{comb}$), X vs. boiling point, and f vs. molecular weight, boiling point and heating value exhibited the high correlation coefficient more than 0.99. Using the regression equation between the heating value of natural gas and Vw the predicted heating values from $C_6$ to $C_{10}$ showed good agreement with those reported in the literature within 0.2% relative error.

  • PDF

Acoustic Characteristics of Sand Sediment with Circular Cylindrical Pores in Water (수중 원통형 다공성 모래퇴적물의 음향특성)

  • 윤석왕;이용주;노희설
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.110-119
    • /
    • 2002
  • Acoustic characteristics of water sediment were experimentally studied in laboratory. Water saturated sand sediment less than the grain size of 0.5 mm diameter is uniformly distributed in an acryl box (100 mm×100mm×42mm) with material thickness 1 mm. Pores in the acryl box are modeled as the structure of cylindrical pore tubes (diameter 3 mm and length 42 mm) filled with water. Cylindrical pore tubes have porosities 0%, 5%, 11%, 18% and 26 % controlled by the tube numbers. Transmitted acoustic waves through sand sediment specimen are analyzed as the functions of porosity and frequency from 0.3 MHz to 4 MHz. Transmitted acoustic waves are mixed with the first-kind wave from whole specimen and the second-kind wane from cylindrical pore tubes. For the center frequency 1 MHz, the first kind wave is dominant but for the center frequency 2.25 MHz, the second kind wave is dominant. In the case of the first-kind wave, as the porosity increases, the transmission coefficient decreases and the sound speed decreases to the sound speed of water. As the frequency increases, the transmission coefficient decreases but the sound speed is almost constant. In the case of the second-kind wave, as the porosity increases, the transmission coefficient increases but the sound speed is almost constant. The transmission coefficient and the sound speed are almost constant as a function of frequency.

Comparison Analysis of MR Images Before and After External Beam Radiotherapy in Brachytherapy (근접치료 시 외부 방사선 치료 전후의 MR 영상 비교분석)

  • Choi, Eun-Hye;Baek, Chung-Seok;Lee, Sung-Yong;Byun, Young-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • Purpose: To analyze availability of MR images before and after external beam radiotherapy in brachytherapy, we will acquire MR images before and after external beam radiotherapy and compare the change of direction of uterine cavity and analyze the accuracy of applicator insertion. Materials and Methods: From January 2009 to December 2010, we compared MR images before and after external beam radiotherapy for uterine cervical cancer only with radical purpose treatment. MR images which was acquired after external beam radiotherapy has done with inserted status of CT/MR applicator. Results: As a consequence, the tumor was markedly reduced after external beam radiotherapy. The change of anteflexion of uterus turned into retroflexion of the uterine cavity was 17.1%. The case of wrong insertion of tandem include direction or length was 14.3%. Conclusion: According to MR images taken after external beam radiotherapy, we recognized not only reduced the tumor volume but the marked change of exact direction or length of the uterine cavity. So the confirmation of accurate insertion based on MR images before brachytherapy could be very helpful for optimal brachytherapy treatment planning with reduced applicator insertion errors.

  • PDF

Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System (공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석)

  • Lho, Tae-Jung;Shon, Tae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.878-885
    • /
    • 2008
  • The FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) and OLED(Organic Light Emitting Diode), recently, have been substituted for CRT(Cathode Ray Tube) displays because they have a convex surface, small volume, light weight and lower electric power consumption. The productivity of FPDs is greatly dependent on the area of thin glass panel with 0.6 - 0.8mm thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass panel. For example, the thin glass panel size of the 8th generation is 2,200mm in width, 2,600mm in length and 0.7mm in thickness. The air flows both in the thin glass panel and in the porous PE-plate surface were modeled and analyzed, from which a working condition was estimated. The thin glass panel on the porous PE-plate surface with self-lubricating characteristics was investigated and compared with that on the square duct floating bar surface with many holes of 1mm diameter when the thin glass panel contacts the floating bar surface due to malfunction of electric power supply.

Comparison of Pectin Hydrogel Collection Methods in Microfluidic Device (미세유체 장치에서 수거 방법에 따른 펙틴 하이드로겔 입자의 특성 비교)

  • Kim, Chaeyeon;Park, Ki-Su;Kang, Sung-Min;Kim, Jongmin;Song, YoungShin;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.740-745
    • /
    • 2015
  • This study investigated the effect of different collection methods on physical properties of pectin hydrogels in microfluidic synthetic approach. The pectin hydrogels were simply produced by the incorporation of calcium ions dissolved in continuous mineral oil. Then, different collection methods, pipetting, tubing, and settling, for harvesting pectin hydrogels were applied. The settling method showed most uniform and monodispersed hydrogels. In the case of settling, a coefficient of variation was 3.46 which was lower than pipetting method (18.60) and tubing method (14.76). Under the settling method, we could control the size of hydrogels, ranging from $30{\mu}m$ to $180{\mu}m$, by simple manipulation of the viscosity of pectin and volumetric flow rate of dispersed and continuous phase. Finally, according to the characteristics of simple encapsulation of biological materials, we envision that the pectin hydrogels can be applied to drug delivery, food, and biocompatible materials.

Study on Shift characteristic of Small reducer using Eccentric arm (편심캠을 이용한 소형감속기의 변속특성에 관한 연구)

  • Youm, Kwang-Wook;Ham, Seong-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.609-614
    • /
    • 2017
  • In this study, a new type of eccentric cam was used for the development of a small size reducer with a two-shift reduction ratio while maintaining the same volume as the existing one-shift speed reducer. Therefore, a two-shift speed reducer was designed using the concept of a continuously variable transmission applied to automobiles. The cam was designed to have an eccentric shape with a $180^{\circ}$ phase difference to act as a tensioner to minimize slip by squeezing the V-belt connected to the deceleration pulley and the acceleration pulley, respectively. The cam was designed to have a diameter of 35mm and an outer diameter of 18mm so that the outer portion of the v-belt could contact the cam perfectly. A pulley with a diameter of 50.8mm was installed on the low speed pulley input shaft for deceleration and a pulley with a diameter of 76.2mm was provided on the output shaft. In the high-speed pulley for acceleration, a pulley with a diameter of 76.2mm is provided on the input shaft, and a pulley with a diameter of 50.8mm is provided on the output shaft. Based on the design details, the power transmission efficiency test and the heating characteristics of the transmission were tested to verify the feasibility. In addition, through validation, the suitability of the reducer was demonstrated.

Drop Impact Analysis of Outside Cooling Unit Package of System Air-Conditioner and Experimental Verification (시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험적 검증)

  • Kim, Hyung-Seok;Lee, Boo-Yoon;Lee, Sanghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • This research examines the drop impact of an external cooling unit package of an air conditioner system. The packaging is composed of a shock-absorbing material, which protects the package contents by absorbing the impact energy and other parts for fixture. Accurate quantification of the impact acceleration experienced by the package contents is necessary to design an effective packaging with minimal volume and sufficient shock absorbing capacity. Explicit time integration was used for the drop impact analyses. A finite element model of the package was constructed, material testing and material model selection were carried out, and sensors for data acquisition were modeled to obtain accurate simulation results. The results were compared with real physical test data. Due to imprecise modeling of the damping, the acceleration and strain values predicted by the simulation were larger than those from physical test. However, the trend of the history data and the peak deceleration value in the direction of impact showed good agreements. Thus, the analysis model and scheme are suitable for the design of an air conditioner cooling unit package.