A Study on the Anti-Corrosion Paint(EH 2350) Compatibility Verification for Naval Surface Vessels's Cavitation (캐비테이션 발생에 따른 해군 수상함정 방청도료(EH 2350) 적합성 검증에 관한 연구)

  • Choi, Sang-Min;Lee, Ji-Hyeog;Beak, Yong-Kawn;Jeong, Hyeon-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.7-12
    • /
    • 2019
  • The naval surface vessels, which were often exposed to harsh marine environment, tended to be corrosive due to military operations on various sea-areas and courses. Although R.O.K Navy applied various methods to protect further corrosion, the hull corrosion occurred due to cavitation were found on the naval surface vessels at regular and occasional docking. Hull corrosion was a critical factor directly to affect the lifetime of ships and their operational capabilities adversely. In this paper, EH 2350, which was the main anticorrosion paint used by R.O.K. Navy, was compared with DuraTough DL by used by the U.S Navy to collect materials related to anti-corrosion paint. In addition, the paint compatibility verification was conducted through wear abrasion test. Assuming that it was exposed to sea-environment various both abrasion cycle and weight for objective verification. by varying both the abrasion cycles and weights. In this study, the reliability of the EH 2350 conformity, which was used in Naval surface vessels, was secured.

A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable (154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究))

  • Lee, D.I.;Kim, J.B.;Jeong, D.W.;Kim, D.K.;Lee, J.B.;Jeong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF

The Corrosion Control Using CCPP(Calcium Carbonate Precipitation Potential )Index in Metallic Coupons ($CaCO_3$침전능 조절에 의한 금속시편에서의 부식방지)

  • 이재인;임진경;서상훈;김동윤;신춘환
    • Journal of Environmental Science International
    • /
    • v.9 no.6
    • /
    • pp.505-509
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of $Ca(OH)_2$ and $CO_2$ additions on the corrosion of metal coupons(ductile iron, galvanized steel, copper and stainless steel). Corrosion rate and released metal ion concentration of ductile iron and galvanized steel decreased by adjusting alkalinity, calcium hardness and pH with $Ca(OH)_2$ & $CO_2$ additions on copper and stainless steel were less than those on ductile iron and galvanized steel. When ductile iron coupon was exposed to water treated with Ca(OH)$_2$&$CO_2$, additions, the main components of corrosion product formed on its surface were $CaCO_3$ and $Fe_2 O_3 or Fe_2 O_4$ which often reduce the corrosion rate by prohibiting oxygen transport to the metal surface.

  • PDF

A Study on the Anchorage Local Stress characteristics of Precast of Precast Prestressed Concrete Beams (프리캐스트 프리스트레스트 콘크리트 부재의 정착부 국부응력 특성에 관한 실험연구)

  • 오병환;임동환;양인환;박상현;장석훈;유승운;김종한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.224-227
    • /
    • 1992
  • 세그멘탈 교량에 포스트 텐셔닝 힘을 도입할 때 발생하는 가장 큰 문제는 균열의 발생이다. 이러한 균열은 실제 구조물의 강도감소 뿐 아니라, 이 균열은 염분 및 수분 침투의 통로가 되어, 부식 및 동결손상의 주원인이 되어 구조안전도에 큰 문제를 유발한다. 본 연구는 국부 집중 하중을 받는 프리스트레스 정착부의 응력분포 특성을 규명하고, 국부집중응력으로 인한 균열 발생 요인을 규명하여, 균열발생방지방안 및 그 대책을 강구함에 그 근본 목적이 있다. 이를 위하여 텐던에 대한 형상, 국부보강방식, 단일 및 복수텐던의 영향, 구조보강 철근량에 따른 콘크리트 내부 변형도 및 균열양상을 도출하기 위해, 부재를 제작하여 실험을 실시하여 균열의 양상 및 균열발생원인을 조사하고, 그 구체적 보강방안을 찾고자 한다.

  • PDF

A Study on the Characteristics of Galvalume Sheet (55%A1-43.4%Zn-1.6%Si) (55% A1 - 43.4% Zn - 1.6% Si 합금도금 강판의 특성에 관한 연구)

  • 김순경
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.310-315
    • /
    • 1997
  • An extensive corrosion study was initiated by galvalume steel sheet manufacturing company to clarify the corrosion behavior of zinc and zinc and zinc-alloy coated automotive sheet steel in out panel and electrical application. Since the early 1980's the use of zinc and aluminum alloy coated steel for vehicular corrosion protection has increased drastically. This paper describes the evaluation of formability, weldability and painted corrosion performance of galvalume steel sheet. This paper presents an overview of the program and some initial test results on the weldability, lifetime of the electrode tip shape of the spot welding and corrosion protection. Galvalume steel sheet improved corrosion performance and spot weldability of galvalume steel has no problem for the variation of welding current. And tip lifetime was changed according to the influence of shape.

  • PDF

PFBC 집진용 세라믹 캔들필터의 기술개발 과제

  • 최주홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.167-170
    • /
    • 1996
  • 석탄의 고압 유동층연소는 기존의 PC 보일러보다는 저온 연소로써 NOx의 발생이 억제되며 탈황제를 동시에 주입하여 SOx 발생을 줄일 수 있는 것이 큰 잇점으로서 석탄 신에너지 개발에 유력한 시스템이다. 본 시스템에서 집진은 연소가스 중의 입자가 고온고압에서 고속으로 터빈에서 충돌될 때 일어나는 터빈의 마모, 침식, 및 부식 등을 방지하기 위하여 필수적이다. PFBC 연소기에서 연소된 가스가 정제후에 바로 가스터빈에 주입되기 때문에 PFBC의 집진은 매우 가혹한 조건이다. 뿐만 아니라 차세대에 더욱 높은 열효율 향상과 가스터빈의 수명 연장을 위하여 집진조건이 더욱 가혹해지고 엄격해질 전망이다. 그 동안 PFBC 집진의 연구가 다방면으로 진행되고 있으나 상용화를 위한 준비가 아직 갖추어지지 않았으며 모든 집진 시스템이 잠정적인 문제점을 갖고 있다. 그 중에서도 세라믹 캔들 필터는 성능이 우수하고 가장 많은 운전경험을 갖고 있기 때문에 가장 가까운 시기에 상용화에 성공할 수 있는 집진 시스템이다. 본 고에서는 세라믹 캔들필터 개발의 현황과 핵심 개발과제에 대하여 논의코자 했다.

  • PDF

Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System (상수도관로의 부식 방지를 위한 수돗물의 침식성 평가)

  • Kwak, Phill-Jae;Lee, Hyun-Dong;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

수치해석을 이용한 화학제주입탱크의 주입시간 특성분석

  • 박병호;김은기;김유환;고용상;장근선
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.55-60
    • /
    • 1996
  • 원자력발전소 운전시 원자로냉각재는 부식 방지를 위해 적절한 화학물질을 함유하고 있어야한다. 이러한 원자로냉각재의 수질화학 조절은 유량조절 기능과 화학제주입 기능을 가진 화학 및 체적제어계통의 화학제주입탱크 및 체적제어탱크에 의하여 이루어진다. 본 연구에서는 영광5,6호기에서 화학제주입계통의 연결위치를 충전펌프 후단에서 전단으로 변경하고, 원자로보충수펌프에 의하여 화학제주입을 수행할 경우 요구되는 주입운전시간 특성에 대해 수치해석을 이용하여 분석하였다. 분석은 설계요건에서 요구되는 화학제주입탱크의 용량 및 주입유량을 고정하고 탱크의 구조적형상 변경, disk block 설치 및 주입속도를 변경(입구배관 크기 변경)하여 각각의 경우에 대하여 시간변화에 대한 탱크 내에서의 유속분포, 농도분포, 평균농도 등 을 구하였다. 분석결과 발전소의 빠른 화학제주입운전을 위해서는 탱크 내에 혼합효과를 중대 시킬 수 있는 disk block의 설치가 요구됨을 알 수 있었다.

  • PDF

The high temperature oxidation behavior of X20CrMoV12.1 high-chromium steel (X20CrMoV12.1 고크롬강의 고온산화거동)

  • 정진성;김두수;김범수;김의현;하정수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.46-46
    • /
    • 2003
  • 고크롬강은 산업용 발전설비의 효율적인 열교환을 위해 수천개의 튜브로 구성된 보일러에 적용되고 있다. 이러한 보일러 튜브는 고온에 노출되어 있으며, 튜브 내면에는 고온의 증기가 고압으로 존재하고 있다. 따라서 보일러 튜브는 장기간 고온의 환경에서 사용되기 때문에 고온강도와 고온내산화 및 내부식 특성이 요구된다. 보일러 튜브의 열화는 이세조직 변화에 따른 고온강도의 저하를 재료내부의 열화와 고온산화 및 부식 등 외부환경에 의 한 열화로 크게 두 가지로 대별된다. 이러한 보일러 튜브의 수명평가는 튜브의 수명을 미리 예측하여 적절한 시점에 교체함으로서 운전 중 손상에 따른 발전정지 등을 방지하여 막대한 비용을 절감할 수 있기 때문에 현장에서는 중요한 의미를 갖는다. 본 연구에서는 보일러 튜브의 여러 가지 수명평가 방법 중 현재 산업용 발전설비의 보일러에 적용되고 있는 X-20 고크롬강의 고온산화 거동을 조사하여 향후 보일러 튜브의 수명평가 방법 중 산화스케일을 이용한 방법에 활용하는데 있어 기초 자료로 이용하고자 한다.

  • PDF

경량재질을 이용한 모듈 타입의 부표 설계에 관한 연구

  • Jeong, Tae-Gwon;Im, Min-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.109-110
    • /
    • 2015
  • 강재 부표는 구조적 강도가 우수하고 철재의 절단, 용접 등의 간단한 가공으로 원하는 모양을 쉽게 만들 수 있는 장점은 있으나, 소재의 특성상 해수에 의한 부식과 흘러나오는 페인트로 인한 환경오염, 무거운 중량, 이에 따른 설치 비용과 유지보수 비용의 증가 등 여러 가지 극복하기 힘든 문제점과 한계점을 가지고 있다. 이 연구에서는 우리나라 표준형 부표의 기본 소재로 사용하고 있는 강재 대신 친환경적인 경량재질의 소재를 이용한 부표를 모듈 구조로 설계함으로써, 기존 강재 부표의 문제점과 한계점을 뛰어넘어 효율적인 유지관리와 운영이 가능하고, 해양환경 오염의 방지와 경량화를 실현시킬 수 있는 표체 개선 방안을 제시하고자 한다. 또한, 경량 재질을 이용한 부표의 안정성과 경제성 검토를 통해, 기존 강재 부표와 비교함으로써 안정성과 경제성을 평가하고자 한다.