• Title/Summary/Keyword: 부식환경

Search Result 1,018, Processing Time 0.025 seconds

Corrosion Characteristics of Catenary Materials in Electric Railway System (전차선로 가선재료의 부식특성)

  • 김용기;윤상인;장세기;이재봉
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.535-542
    • /
    • 2000
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as Catenary Materials in Electric Railway System. Since these materials may have chance to be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important not only to investigate the corrosion characteristics but also to measure corrosion rates in various corrosive environments. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization. a.c impedance spectroscopy and galvanic corrosion tests were carried out in these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effect on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

A Preliminary Study on the Reused Channel-Type Lining Board with Corrosion-Damage (부식 강재 복공판의 재사용성 평가에 관한 기초적 연구)

  • Kim, In-Tae;Kim, Dong-Woo;Choi, Hyoung-Suk;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.170-179
    • /
    • 2009
  • Channel-type lining board(CLB) is a welded steel structure used in the field of open cut subway excavation and building basement construction. Lining board is generally installed at the underground environment which is exposed to corrosion factors such as humidity, temperature and corrosive gases. This study evaluates reusability of the corroded lining board by experimental and analytical method. Static loading tests were performed to know serviceability of corroded CLB after checking thickness loss of the used CLB parts. Strain of the plates and middle point deflection was measured simultaneously. According to experimental test results and comparison with numerical analysis, the thickness loss of the plates by corrosion makes more vertical displacements and stresses in members under the DB vehicle load considering impact factor. As a result, this paper is proposed a way to evaluate used and corroded CLB by checking the plates thickness and it makes construction engineers easy to know optimal time to replace their old CLBs with new one.

플로팅 건축용 콘크리트 구조물의 철근 겹이음 거동

  • Yang, In-Hwan;Sin, Jae-Hyeok;Kim, Gyeong-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.213-215
    • /
    • 2015
  • 플로팅 건축용 콘크리트 구조물은 부식환경에 노출되어 매립된 철근의 부식에 따른 구조물의 내구성능에 문제가 발생하게 된다. 철근 부식에 의한 내구성이 저하되는 문제의 여러 효과적인 해결방법 중 하나로 철근 코팅 기법이 있으며, 철근의 용융아연도금시 표면에 용융아연층이 형성되어 철근을 보호하는 장점이 있으나 콘크리트와의 부착 성능에 대한 연구는 미비한 실정이다. 따라서, 본 연구에서는 플로팅 건축용 콘크리트 구조물의 철근 겹이음에 따른 거동 특성연구를 수행하였다.

  • PDF

직류전류에 의한 전식 방지법-배류법

  • 이지인
    • 전기의세계
    • /
    • v.44 no.4
    • /
    • pp.42-49
    • /
    • 1995
  • 산업이 고도로 발달하게 됨에 따라 가스관, 상하수도관, 송유관등의 시설이 필요하게 되고 이런 시설들은 도심에서 지하에 매설되게 된다. 지하에 매설되는 금속배관은 토양중에서 부식환경에 놓이게 되며 자연부식을 방지하기 위하여 도장등의 방식방법과 병행하여 전기화학적 반응을 이용한 전기 방식 방법을 채택하여 실시하고 있다. 그러나 도시 교통난 해소를 위하여 직류로 운행되는 전기철도가 시설되면서 직류전기철도에서 누설전류가 발생하게 되고 누설전류는 지하매설물에 영향을 미쳐 심각한 부식을 일으키게 된다. 본 글에서는 금속의 부식과 직류전류에 의한 전식에 대하여 기술하고 여러가지 전기방식방법과 직류전기철도에 의한 전식방지대책 적용 및 시공사례, 기타 전식방지대책에 대하여 기술한다.

  • PDF

PWSCC of Alloy 600 components in PWRs-Part 1 (원자력 발전소 Alloy 600 부품의 PWSCC-Part 1)

  • Hwang, Seong Sik
    • CORROSION AND PROTECTION
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Alloy 600 재료의 PWSCC의 개념을 소개하고 그 발생과 전파에 미치는 미세조직, 온도, 응력, 수화학 환경등의 주요인자를 정리하였다. ◯ PWSCC란 니켈 기지 합금인 Alloy 600와 그 용접재인 Alloy 82/182 재료가 원자로 1차수 환경에서 보이는 응력부식균열을 의미한다. ◯ Alloy 600의 PWSCC에 미치는 주요 인자에는 재료의 미세조직, 응력, 온도, 환경등이 있으며 그 중에서 재료의 미세조직이 가장 지배적인 인자이다. ◯ 재료내의 탄화물은 탄소 함량과 열처리 조건에 따라 달리 형성되며 입계를 따라 준연속적으로 잘 발달된 입계탄화물을 가지는 재료가 PWSCC에 저항성을 가진다. ◯ 손상속도는 부가 응력의 네 제곱에 비례하여 증가하는 것으로 알려져 있다. ◯ PWSCC는 Arrhenius 관계의 열활성화 과정(thermally activated process)이다. ◯ 용존수소량에 따라 재료의 부식전위가 정해지는데 전극전위가 Ni/NiO 평형전위 부근에서 가장 큰 균열 성장 민감도를 보인다는 데는 연구자들 사이에 이견이 없다. 그러나 균열의 개시에 대한 용존수소량의 영향에 대해서는 이견이 있다.

Edge Vegetation Structure in the Mt. Sokri National Park (속리산 국립공원의 주연부식생구조)

  • 오구균;권태호;이재영
    • Korean Journal of Environment and Ecology
    • /
    • v.4 no.1
    • /
    • pp.44-50
    • /
    • 1990
  • To investigate edge vegetation structure in the Mt. Sokri National Park, field survey was executed in August. 1990 and the result are as follows. Dominant edge species by crown-layer and smilarity of species composition seemed to be affected by existing upper layer vegetation, altitude aspect and physiographical location. and the edge vegetation at summit was severely different with one of the other environmental types. Species diversity of edge vegetation was highest at Northern midslope, lowest at Southern mid-slope. and Acer pseudo-sieboldiamun var. koreanum was appeared as a dominant species at all environmental types. Frequency classes of edge species were different by altitude, aspect, physiographicallocation. Acer pseudo-sieboldiamun var, koreanum, Quercus mongolica, Fraxinus rhynchophylla, Lespedeza maximowiczii, Weigela subsessilis showed high frequency class at all environmental condition.

  • PDF

Technology for Controlling Biochemical Corrosion by Sulfur-oxidizing Bacteria of Sewage Concrete Construction applied Antimicrobial Concrete (항균 콘크리트를 적용한 정화조 및 하수처리 콘크리트 구조물의 황산화세균에 의한 생화학적 부식 저감 기술)

  • Kim, Do-Su;Khil, Bae-Su;Sohn, Yu-Shin;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.907-910
    • /
    • 2008
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biochemical reaction originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which inhibit growth of sulfur-oxidizing bacteria have to be developed and applied necessarily. In this study, we are going to introduce technology which biochemical corrosion of sewage facilities concrete could be controlled effectively by antibiosis of antimicrobial concrete

  • PDF

Effect of Polyacrylic Acid Concentrations to the SA106 Gr.B and Alloy 690 Materials at the Startup Environments of Secondary Water Chemistry of NPP System (원전 기동시 2차측 수질 환경에서 SA106 Gr.B와 Alloy 690 재료에 미치는 고분자 아크릴산 농도 영향)

  • Gwon, Hyeok-Cheol;Lee, Du-Ho;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.118-119
    • /
    • 2014
  • 원전 운전 중 2차계통 구성재료가 부식되어 철 산화물이 증기발생기 내부로 유입된다. 유입된 철산화물은 고온고압의 환경에서 침적되어 슬러지가 된다. 침적된 슬러지는 증기발생기 전열관 재료에 응력부식균열(SCC)을 일으키는 주원인으로 원전에서는 철 산화물의 유입을 최소화하기 위해 기동전 2차계통을 순환 세정하고 있다. 해외 원전에서는 고분자 아크릴산(Polyacrylic Acid)을 순환세정시 주입함으로써 2차계통 철 산화물 제거 효율을 높인 사례가 있었다. 이에 우리 원전에서도 기동전 순환세정시 고분자 아크릴산을 주입 적용하였다. 고분자 아크릴산 주입 전 필수적으로 이뤄져야할 연구는 고분자 아크릴산이 재료에 미치는 영향평가이다. 본 연구에서는 고분자 아크릴산 농도(1, 10, 100 ppm)에 따라 2차계통 구성재료인 SA106 Gr.B와 Alloy 690의 건전성에 미치는 영향를 수행하였다. 평가방법으로는 전기화학 분극실험, 시편을 침지시켜 실험 전, 후 무게 감량을 이용한 부식률 측정, 표면 상태분석등을 이용하여 종합적으로 평가하였다. 전기화학 분극실험과 부식률 측정결과, 고분자 아크릴산 농도가 높을수록 부식은 증가하였고 고분자 아크릴산 농도 100 ppm일 때 최대 부식률이 0.037 mils로 계산되었다. 이는 부식허용 기준치(5.8 mils)보다는 100배이상 낮았으며 표면분석 결과 고분자 아크릴산으로 인한 pitting 부식은 발생하지 않았다. 이와 같은 결과로 기동시 환경에서 고분자 아크릴산 농도 100 ppm까지는 재료 건전성에 미치는 영향은 거의 없는 것으로 판단된다.

  • PDF

A Study on Rotary Bending Fatigue Strength of the $CO_2$ Gas Welded Joint in Air and Sea Water ([$CO_2$] 용접이음재의 대기 및 해수중에서의 회전굽힘 피로강도에 관한 연구)

  • S.W. Kang;S.Y. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.118-126
    • /
    • 2000
  • TMCP steel has been widely used to construct ships and offshore structures. When it comes to ship and offshore structures, corrosion fatigue damages caused by sea water and fatigue occurred by wave-induced forces usually go on occurring simultaneously. So the fatigue life in corrosion environment is decreased markedly in comparison with that in air. The fatigue crack in corrosion easily initiates on welded joints of structure like as the fatigue crack in air. Therefore it is very important to study the fatigue properties of those of their welded joints as well as steel plates. In this study, rotary bending fatigue tests have been performed to investigate fatigue crack initiation and behavior of fatigue crack growth on CO2 gas weld HAZ of TMCP steel. The fatigue test used the specimens with various stress concentration factors in air and 3% NaCl solution

  • PDF

Chloride Threshold Value for Steel Corrosion considering Chemical Properties of Concrete (콘크리트의 화학적 특성을 고려한 철근 부식 임계 염소이온 농도)

  • Song, Ha-Won;Jung, Min-Sun;Ann, Ki Yong;Lee, Chang-Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.75-84
    • /
    • 2009
  • The present study assesses the chloride threshold level for corrosion of steel in concrete by examining the properties of four different binders used for blended concrete in terms of chloride binding, buffering of cement matrix to a pH fall and the corrosion behaviour. As binders, ordinary Portland cement (OPC), 30% pulverised fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF) were used in a concrete mix. Testing for chloride binding was carried out using the water extraction method, the buffering of cement matrix was assessed by measuring the resistance to an artificial acidification of nitric acid, and the corrosion rate of steel in mortar with chlorides in cast was measured at 28 days using an anodic polarisation technique. Results show that the chloride binding capacity was much affected by $C_{3}A$ content and physical adsorption, and its order was 60% GGBS>30% PFA>OPC>10% SF. The buffering of cement matrix to a pH fall was varied with binder type and given values of the pH. From the result of corrosion test, it was found that the chloride threshold ranged 1.03, 0.65, 0.45 and 0.98% by weight of cement for OPC, 30% PFA, 60% GGBS and 10% SF respectively, assuming that corrosion starts at the corrosion rate of $0.1-0.2{\mu}A/cm^{2}$. The mole ratio of [$Cl^{-}$]:[$H^{+}$], as a new presentation of the chloride threshold, indicated the value of 0.008-0.009, irrespective of binder, which would be indicative of the inhibitive characteristic of binder.