• Title/Summary/Keyword: 부식억제

Search Result 234, Processing Time 0.025 seconds

Evaluations of Corrosion Resistance of Coated Steel Using Polymer Cement Slurry (폴리머 시멘트 슬러리로 코팅한 도장철근의 내식성 평가)

  • Jo, Young-Kug;Kim, Young-Jib;Soh, Yang-Seob
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.117-124
    • /
    • 2003
  • Reinforced concrete structures under sever conditions such as marine structures, bridges and structures constructed with aggregates(dredged from sea), can be deteriorated from corrosion of the reinforcing bars. The purpose of this study is to evaluate the anti-corrosive performance of coated steel using polymer cement slurry. Polymer cement slurry with various polymer dispersions and corrosion inhibiting agent were coated to the surface of bars, and tested for accelerated corrosion tests. Tests include immersion in NaCl 10% solution, chloride ion spray, autoclave cure, autoclave cure after carbonation, penetration of NaCl 10 % solution, carbonation after penetration of NaCl 10% solution. Test results, show that the anti-corrosive performace is considerably improved by using polymer cement slurry at surface of steel. And this trend is marked by adding of corrosion inhibiting agent. This difference of the anti-corrosive properties is hardly recognized according to types of polymer dispersions. The coated steel using polymer cement slurry will be improved to a great extent compared to those of plain steel when increasing content of chloride ion in cement concrete.

Characteristics of Flexural Behaviors for Marine Concrete Members Using High-Durable Materials (고내구성 재료를 사용한 해양 콘크리트 부재의 휨 거동 특성)

  • Yang, Eun-Ik;Kim, Myung-Yu;Park, Hae-Geun;Lee, Dong-Gun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.249-256
    • /
    • 2008
  • The durability of marine concrete structure is severely degraded by corrosion due to penetration and diffusion of chloride. So, many researches have been performed to improve the durability in marine concrete structure. In this study, the concrete members mixed with the mineral admixtures(SF and BFS), the epoxy-coated steel, and corrosion inhibitors are prepared, and four-point bending test of specimens are performed to investigate the flexural behaviors and the applicability for marine concrete structure. From the test results, the mineral admixtures and inhibitors are useful for safety against the initial cracking and the bending resistance in specimens. When the durable material is used in specimen, the tensile stress of reinforcing rod was less variable in same bending span length, and the durable member showed a stable behavior. And it is evaluated that the crack spacing is not larger in specimen used the durable material.

Experimental Study on the Corrosion Characteristics of Zn and Zn-15Al Coatings Deposited by Plasma Arc Thermal Spray Process in Saline Solution (플라즈마 아크 용사 공법에 의해 도포된 Zn 및 Zn-15Al 금속 코팅의 해수 환경에서 부식 특성에 관한 실험적 연구)

  • Jeong, Hwa-Rang;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.539-550
    • /
    • 2021
  • In this study, Zn and Zn-15Al were coated on general carbon steel by plasma arc metal spraying and then immersed in a 3.5wt.% NaCl solution similar to the seawater environment to evaluate the corrosion resistance properties. Through the surface shape analysis test by SEM and XRD, it was found that the Zn coating was porous and needle-shaped, so the penetration of the electrolyte was easy, and thus the corrosion rate was rapid. On the other hand, the Zn-15Al coating had a uniform and dense shape and was shown to suppress corrosion.

Effect of Impressed Current System for Corrosion Protection of Rebars in Concrete (콘크리트 중의 철근 부식 억제를 위한 외부전원법의 효과)

  • Moon, Han-Young;Kim, Seong-Soo;Kim, Hong-Sam
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.221-230
    • /
    • 1999
  • Corrosion of rebars can occur if there are cracks, moisture and availability of oxygen or carbonation proceeds, chloride penetrates and diffuses in concrete. Once rebars in concrete corrodes, subsequently accompanied with scaling, spalling in concrete cover. As a result of them, the RC structure is seriously deteriorated. In this study, theoretical review and experiments for cathodic protection(CP) have been performed to control corrosion of rebars in concrete contained chlorides and pre-crack. For CP the impressed current system was applied, the protection effect was investigated when rebars was directly contacted with salt water due to crack and open to much chlorides in concrete. In order to investigate the effect of protection, when CP was energized for 1 year, half-cell potential, potential-decay with current density, corrosion ratio, etc. were measured. With the cathodic protection by impressed current system, the depolarized values of all specimen were met NACE Standard, the effect of 34~84% of the ratio of corrosion area and 84~86% of cross-section reduction were calculated.

Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System (배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계)

  • Woo, Dal-Sik;Ku, Sung-Eun;Lee, Byung-Doo;Kim, Ju-Hwan;Moon, Kwang-Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

A Study on the Inhibiting Corrosion of Triethanolamine for the SCM440 Steel (CM440 강에 대한 트리에탄올아민의 부식억제에 관한 연구)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.56-61
    • /
    • 2015
  • In this study, the current-voltage curves for the SCM440 steel by the addition of an organic corrosion inhibitor triethanolamine(TEA) was measured using the conventional three electrodes of cyclic voltammetry. As a result, the C-V characteristics of SCM440 steel were to be for an irreversible process due to the oxidation current from the cyclic voltammetry. Diffusion coefficient according to the twice increasing the concentration of TEA in the corrosion inhibitor from $2.5{\times}10^{-4}M$ to $5.0{\times}10^{-4}M$, the diffusion coefficient was found to be a good corrosion-inhibiting effect is reduced by 1.5 times, so for each $2.561{\times}10^{-6}cm^2s^{-1}$ to $1.707{\times}10^{-6}cm^2s^{-1}$. When according to the electrolyte concentration and the effect is to increase the electrolyte concentration to 1.0 N at 0.5 N, the diffusion coefficient is $2.56{\times}10^{-6}cm^2s^{-1}$ to $5.12{\times}10^{-6}cm^2s^{-1}$, each 2 times decrease in the use of the electrolyte of 1.0 N, because this was more appropriate.

Proposed Prediction of Corrosion Loss for Weathering Steel Cladding in KIHO region using Multi-variable Analysis (기호지방 건축용 내후성강 외장재의 다변량 해석을 통한 부식량 예측식 제안)

  • Chung, Kyung Soo;Lee, Jae Sung;Chung, Jin An;Lee, Sung Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.591-599
    • /
    • 2008
  • Weathering steel has been widely used in bridges and cladding materials due to its superior atmospheric corrosion resistance. Actually, weathering steel has often been used in Korea as cladding material. However, the performance of the weathering steel in claddings has not been fully monitored. We conducted a field study on the performance of weathering steels and measured the quantity of corrosion loss on the weathering steel claddings in Korea. Based on the measured corrosion loss and weather (environmental) data, the equation to predict corrosion loss of weathering steels was proposed by using environmental factors in KIHO region in Korea. The proposed equation predicted very well the real corrosion losses of KIHO region.

Corrosive control of the water produced by SWRO and Application to small dimensional Pilot Plant (SWRO 생산수의 부식성 제어를 위한 목표 수질 연구 및 소규모 Pilot Plant 적용)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Moon, Jung-Gi;Kwak, Moung-Hwa
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.1042-1045
    • /
    • 2009
  • 역삼투식 해수담수화 (Sea Water Reverse Osmosis, SWRO) 공정에 의한 생산수는 pH가 낮고, 해수 내 존재하는 경도성분인 Ca, Mg 이온이 대부분 제거되기 때문에 상대적으로 매우 강한 부식성을 지니고 있다. 이를 음용수 및 공업용수로 이용 시 설비 및 배관계통에 심각한 부식문제를 유발할 수 있으며, 이를 방지하기 위한 처리공정과 부식성 제어 기술의 지속적인 개발이 요구되는 실정이다. SWRO 1단으로 처리 시 생산수의 전기전도도는 $150{\mu}S/cm$ 정도의 범위를 보이며, 2단 SWRO 과정을 거칠 시 전기전도도는 $100{\mu}S/cm$ 이하의 범위를 나타내는 것으로 알려져 있다. 본 연구에서는 SWRO 2단 처리수를 가정한 $20{\mu}S/cm{\sim}25{\mu}S/cm$ 범위의 전기전도도를 지닌 물을 실험 원수로 사용하여, 기존 방식제의 성분과 생산수의 특성을 고려한 효율적인 알칼리성 수처리제를 적용하고 그에 대한 부식성 제어 연구를 수행하였다. SWRO 생산수를 대상으로 부식방지기술을 개발하기 위해서는 부식제어와 관련된 수질 인자인 pH, 칼슘경도, 알칼리도의 조절과 LSI(Langelier Saturation Index)를 설정하는 것이 무엇보다도 중요하다. 본 연구에서는 해수담수화 공정의 생산수를 음용수 및 공업용수로 이용하기 위한 목표 수질을 pH 7.5~7.8, LSI 0 이상, 부가적으로 전기전도도는 $250{\mu}S/cm$ 이하로 설정하였으며, 연구목표 수질을 달성할 수 있는 부식억제제 및 알칼리성 수처리제의 적용을 통해 목표 수질에 대한 설정 근거를 마련하고자 하였다.

  • PDF

CMP 컨디셔닝 공정에서의 부식방지를 위한 자기조립 단분자막의 적용과 표면특성 평가

  • Jo, Byeong-Jun;Gwon, Tae-Yeong;Venkatesh, R. Prasanna;Kim, Hyeok-Min;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • CMP (Chemical-Mechanical Planarization) 공정이란 화학적 반응과 기계적 힘을 동시에 이용하여 표면을 평탄화하는 공정으로, 반도체 산업에서 회로의 고집적화와 다층구조를 형성하기 위해 CMP 공정이 도입되었으며 반도체 패턴의 미세화와 다층화에 따라 CMP 공정의 중요성은 더욱 강조되고 있다. CMP 공정은 압력, 속도 등의 공정조건과, 화학적 반응을 유도하는 슬러리, 기계적 힘을 위한 패드 등에 의해 복합적으로 영향을 받는다. CMP 공정에서, 폴리우레탄 패드는 많은 기공들을 포함한 그루브(groove)를 형성하고 있어 웨이퍼와 직접적으로 접촉을 하며 공정 중 유입된 슬러리가 효과적으로 연마를 할 수 있도록 도와주는 역할을 한다. 하지만, 공정이 진행 될수록 그루브는 손상이 되어 제 역할을 하지 못하게 된다. 패드 컨디셔닝이란 컨디셔너가 CMP 공정 중에 지속적으로 패드 표면을 연마하여 패드의 손상된 부분을 제거하고 새로운 표면을 노출시켜 패드의 상태를 일정하게 유지시키는 것을 말한다. 한편, 금속박막의 CMP 공정에 사용되는 슬러리는 금속박막과 산화반응을 하기 위하여 산화제를 포함하는데, 산화제는 금속 컨디셔너 표면을 산화시켜 부식을 야기한다. 컨디셔너의 표면부식은 반도체 수율에 직접적인 영향을 줄 수 있는 scratch 등을 발생시킬 뿐만 아니라, 컨디셔너의 수명도 저하시키게 되므로 이를 방지하기 위한 노력이 매우 중요하다. 본 연구에서는 컨디셔너 표면에 연마 잔여물 흡착을 억제하고, 슬러리와 컨디셔너 표면 간에 일어나는 표면부식을 방지하기 위하여 소수성 자기조립 단분자막(SAM: Self-assembled monolayer)을 증착하여 특성을 평가하였다. SAM은 2가지 전구체(FOTS, Dodecanethiol를 사용하여 Vapor SAM 방법으로 증착하였고, 접촉각 측정을 통하여 단분자막의 증착 여부를 평가하였다. 또한 표면부식 특성은 Potentiodynamic polarization와 Electrochemical Impedance Spectroscopy (EIS) 등의 전기화학 분석법을 사용하여 평가되었다. SAM 표면은 정접촉각 측정기(Phoenix 300, SEO)를 사용하여 $90^{\circ}$ 이상의 소수성 접촉각으로써 증착여부를 확인하였다. 또한, 표면에너지 감소로 인하여 슬러리 내의 연마입자 및 연마잔여물 흡착이 감소하는 것을 확인 하였다. Potentiodynamic polarization과 EIS의 결과 분석으로부터 SAM이 증착된 표면의 부식전위와 부식전류밀도가 감소하며, 임피던스 값이 증가하는 것을 확인하였다. 본 연구에서는 컨디셔너 표면에 SAM을 증착 하였고, CMP 공정 중 발생하는 오염물의 흡착을 감소시킴으로써 CMP 연마 효율을 증가하는 동시에 컨디셔너 금속표면의 부식을 방지함으로써 내구성이 증가될 수 있음을 확인 하였다.

  • PDF

Buffer Intensity of Ammonia and MPA in Water-Steam Cycle of PWRs (가압경수로 원전 물-증기 순환영역에서 암모니아와 MPA의 완충세기)

  • Rhee, In-H.;Ahn, Hyun-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2708-2712
    • /
    • 2010
  • Amines, ammonia or 3-methoxypropylamine (MPA), are used to maintain the optimized pH for the prevention of corrosion in the secondary side of Pressurized Water Reactors (PWRs). They are differently dissociated as a function of temperature which is not same in each location of the water-steam cycle. pH at the operation temperature depends on temperature of fluid and equilibrium constants of water and amines. Thus, every amine provides the different pH in the entire secondary side so that pH is not only the sufficient parameter in corrosion control. The secondary parameter, i.e., buffer intensity, is the ability to maintain a stable pH when $H^+$ are added or removed due to the ingress of impurities or the reaction of corrosion. The buffer intensity is necessary to provide the selection criteria for the best pH control agent for secondary side and the basic understanding of the reason why the flow-accelerated corrosion(FAC) rate may demonstrate the bell-shape curve over temperature. The buffer intensities of ammonia and MPA were reviewed over the entire operation temperature of PWRs. The sufficient buffer intensity is provided for the inhibition of corrosion by ammonia in low temperature $(25{\sim}100^{\circ}C)$ and by DMA in high temperature $(150{\sim}250^{\circ}C)$. In terms of buffer intensity, i) the best pH control agent is an amine with $pK_a(T)$ range of pH(T)- $1{\leq}pK_a(T){\leq}pH(T)$ + 0.5 and ii) the amine solution should have sufficient buffer intensity, ${\beta}$ to inhibit corrosion, and iii) FAC rate may be maximum at the temperature, where ${\beta}_B/{\beta}$ ratio is lowest.