• Title/Summary/Keyword: 부식성지수

Search Result 12, Processing Time 0.021 seconds

A Study on the Relation of Rebar Corrosion Rate and the Strength Reliability Index of RC Slab Decks having Chloride Contamination (염해 손상을 받는 RC 교량 바닥판의 강도 신뢰성 지수와 철근 부식도 등급과의 관계 연구)

  • Cha, Chul-Jun;Park, Mi-Yun;Cho, Hyo-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2005
  • This study focuses on evaluating the reliability index of a deck of RC slab having chloride contamination and studying the relation of grades of rebar corrosion and the reliability index of a bridge deck For this purpose, first, the failure probability related to flexural strength was calculated using a model for deterioration, which contains the application of deicing salts that usually causes significant long-term deterioration and reduction in the structural safety for strength of structure. And also, according to the depth of covering, the chloride contents depending on time due to depths of RC slab deck, the appearance time for initial corrosion of rebar and the occurrence time for split of covering were investigated using a MCS method.

Reliability Analysis Models for Maintenance of bridge structures (교량구조물의 유지관리를 위한 신뢰성 해석 모델)

  • Kim, Jong-Gil;Sohn, Yong-Woo;Lee, Cheung-Bin;Ahn, Young-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.251-261
    • /
    • 2004
  • Recently, the corrosion and aging of bridge structures are of great concern impractical The uncertainties of the corroded reinforced bars in concrete influence not only the safety of the bridge structures, but also the flexural strength of reinforced concrete members. This paper considers these uncertainties by providing a reliability-based framework and show that the identification of the optimum maintenance scenario is a straightforward process. This is achieved by using a computer pro망am for Life Cycle Cost Analysis of Deteriorating Structures (LCCADS). This program can consider the effects of various types of actions on the reliability index profile of a deteriorating structures.

Study on corrosion characteristics of treatment plants in Korea (국내 정수장의 부식성 특성 연구)

  • Min, Byung-dae;Chung, Hyen-mi;Lee, Lee-nae;Choi, Inchol;Ahn, Kyunghee;Park, Ju-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.707-714
    • /
    • 2016
  • In order to prevent secondary pollution of tap water, corrosion characteristics are investigated, and corrosion index are calculated using LI and LR to manage corrosiveness. As targeted water treatment plants from 2014 (July, once) to 2015 (July and October, 2 times), 70 plants are selected by making a division for each area and water system. (treated water samples, n=240, raw water samples, n=72). In result of pH analysis, treated water was lower than raw water to 7.12, and 7.29, respectively. LI were investigated in the order of Seomjin river, Nakdong river, Han river, Geum river, to -2.08, -1.24, -1.11, -1.10 (at raw water), and -2.18, -1.59, -1.51, -1.35 (at treated water), respectively. In case of water quality goal value (LI = -1) in Japan as control of corrosiveness, management object was investigated about 83.3%.

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

Evaluation on Corrosion Behaviour and Adhensivity of Oxide Coated Materials (산화물 피복강재의 부식거동 및 밀착성 평가)

  • Lee Jong-Rark
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.34-41
    • /
    • 1998
  • To oxide film, $A1_2O_3,\;Ta_2O_5$ and $ZrO_2$, coated on stainless steel (SUS410, SUS304) and pure Fe using RF magnetron sputtering method, the corrosion resistance on oxide coatings was studied using electrochemical measurement. Also, the adherence between film and substarte was studied. The adherence index ( $\chi$ ) was determined by the measure of micro hardness test. In this paper, we know that oxide film coated on SUS304 have better corrosion resistance than that coated on SUS410. In oxide film, the difference of corrosion resistance due to crystal structure have not been showed. In evaluating defect area rate of ceramic coated materials, CPCD method can be used effectively. In the micro-hardness test, with $1{\mu}m$ thickness film, it has only one the value of $\chi$. Above $2{\mu}m$ thickness film, however, get another value of $\chi$ as the cracks in film. The oxide film adhere well on the mild materials such as pure steel than high intensity materials like stainless.

  • PDF

Durability Analysis of Underground Structure based on Limit State Function Considering Carbonation (탄산화 기반의 한계상태함수를 활용한 지하구조물의 내구성 평가)

  • Choo, Jin-Ho;Lee, Tae-Jong;Yoon, Tae-Gook;Lee, Sang-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.69-75
    • /
    • 2014
  • The priority of repair areas are chosen with the probability distribution of 0.3mm wide crack and carbonation induced corrosion. Data is analyzed and evaluated based on the 28 section of Precise Inspection for Safety and Diagnosis (PISD) in seoul. As the crack is distributed in log-normal, the carbonation and cover are in normal distribution. To have rational in repair sections among 503 sheets of underground structure, it is adopted the reliability index as well as the environment factors: strength, sonic speed, $CO_2$ concentration, corrosion, and content of chloride.

Improvement of standardization plan for the stable of dam reservoir field (댐 이수안전도 표준화 방안 개선)

  • Sung, Ji Young;Kang, Boo Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.298-298
    • /
    • 2022
  • 최근 우리나라는 과거에 비해 기후변화 등의 사유로 가뭄과 홍수가 증가하는 추세에 있으며, '90년대에 들어서는 대규모의 홍수와 극심한 가뭄이 거의 매년 되풀이 되고 있어 지역간 물수급·공급의 불균형이 심각하여 국민이 활용가능한 수자원확보량과 공급가능량이 많은 차이를 보이고 있다. 기후패턴 변화 및 지속적인 용수수요 증가로 인해 가뭄 발생 위험이 커지고 있으나, 신규 수자원개발은 지역갈등 유발 등 사회적 여건에 따라 불가하므로, 기존댐을 평가하고 효율적으로 활용한다는 것은 기존 수자원을 최대한 활용하여 그 가치를 재조명하고 감춰져 있는 수자원을 다시 찾아내어 활용한다는 점에서 큰 의미가 있다. 허나, 댐 용수공급 안정성을 재평가하기 위한 그간 수많은 노력이 이루어지고 있으나, 용수공급 안정성(이수안전도) 기준은 댐 건설 당시 시대적 여건 등에 따라 다르게 적용되어 표준화된 기준이 전무한 실정이다. 이에 따라 국민의 물이용 보장 등 수요자 입장을 고려한 댐별 표준화된 이수안전도 기준 마련이 시급하다고 판단되며, 본 과업을 통해 댐마다 달리 적용된 이수 안전도를 개선하여 형평성을 고려한 국민 물이용 보장 등을 구현할 수 있는 댐 이수안전도 표준화 및 개선방안을 도출하고자 한다. 표준화된 기준을 통하여 신규댐 설계, 기존댐 평가, 갈수 대책용량 결정 등과 관련하여 용수공급 능력 평가 시 혼란을 사전에 예방하고, 본 연구에서는 수자원 시스템의 용수공급 안정성(이수안전도)을 평가하고 표준화 방안을 마련하기 위한 정량적이고 객관적인 지표를 개발하였고 이를 댐설계 기준 등 국가계획에 반영하여 지침 화할 수 있는 방안을 연구하였다.

  • PDF

Study on characteristic for Larson's ratio of water treatment plants (국내 정수장의 Larson's ratio 특성에 관한 연구)

  • Min, Byung-dae;Chung, Hyen-mi;Ahn, Kyung-hee;Park, Ju-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.579-586
    • /
    • 2016
  • In many countries in order to manage corrosion of water treatment process, it is currently using Langelier index (LI). However, management of the Larson's ratio (LR) to compare corrosion management and LI which can be generated by the water treatment process is required. In this study, in order to ensure data LR, factors associated with the actual corrosion resistance of water treatment plant was measured. Using the measured data, the model equation can be estimated alkalinity, and using the statutory water quality data, LR and alkalinity is estimated. At comparison of the measured value and estimated value of alkalinity, it appeared in $R^2$ = 0.629, using the statutory water quality data and estimated alkalinity model, LR and alkalinity (Whole water treatment plants : 472) is estimated. Concentration of estimated alkalinity is 0.5 mg/L to 107.5 mg/L (average : 23.2 mg/L), and LR is 0.1 to 10 (average : 1.3). At tendency to corrosion of investigated LR, "No metal tendency" (>0.5) is 39 water treatment plants, 8.26 %, and "corrosion metal tendency" is 433 water treatment plants, 91.74%.

Reliability Assessment of Concrete Beams Reinforced with GFRP Bars (FRP 보강근을 사용한 콘크리트 보의 신뢰성 해석)

  • Nam, Ho-Yun;Seo, Dae-Won;Han, Byum-Seok;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.185-188
    • /
    • 2008
  • Fiber reinforced polymer(FRP) bars are proving to be a valuable solution in the corrosion problem of steel reinforced concrete structures. As such, a number of guidelines for their use have been developed. These guidelines are primarily based on modifications to existing codes of practice for steel reinforced concrete structures. These guidelines are also similar in that though the design equations are presented in the partial factor formats that are often used in probability based design, they are not true probabilistic codes. Instead, they typically make use of already existing design factors for loads and resistances. Thus, when concrete structures reinforced FRP bars are designed, the structural reliability levels are not known. This paper investigates uncertainties of concrete beams reinforced with GFRP bars. Also, the structural reliability levels are evaluated for the flexural failure mode.

  • PDF

Drought frequency analysis for multi-purpose dam inflow using bivariate Copula model (이변량 Copula 모형을 활용한 다목적댐 유입량 가뭄빈도해석)

  • Sung, Jiyoung;Kim, Eunji;Kang, Boosik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.340-340
    • /
    • 2021
  • 가뭄의 특성상 시점과 종점을 명확하게 정의하기 어렵기 때문에 기준수문량을 설정하고 부족량과 지속기간을 정의하는 것이 일반적이다. 대상 수문량은 강우나 유출량을 사용할 수 있지만, 두 성분간 지체와 감쇄효과로 인하여 빈도해석의 결과는 차이를 보일 수 밖에 없어, 사용 목적에 따라 선별적으로 적용해야 한다. 가뭄빈도해석은 강우를 기반으로 지속기간과 심도를 정의하여 빈도를 해석하는 연구가 선행되어왔지만, 기본적으로 강우의 간헐적 발생특성과 체감도의 한계가 문제로 지적되고 있다. 본 연구에서는 댐 유입량의 Run 시계열 특성을 이용하여 다양한 유황을 기준유량으로 활용하여 가뭄의 시점과 종점에 대한 가뭄사상을 추출하고 지속기간과 누적부족량을 계산하여 가뭄빈도해석의 변수로 설정하였다. 두 변수간의 복잡한 상호 관계를 해석하기 위해 Copula 함수를 이용한 이변량 가뭄빈도해석을 진행하였다. 먼저 소양강댐('74-'19) 유입량, 충주댐('86-'19) 유입량을 연구대상지역으로 설정하여, 두 유역의 유입량의 추세분석을 통해 시간의존성을 파악하였다. 유황분석에 사용되는 분위량중 평수량을 기준값으로 사용하여 각 년별 최대 지속기간과 누적부족량을 추출하였다. Copula 가뭄빈도해석을 수행하기 전에 지속기간에는 GEV, 누적 부족량에는 Log-normal 분포를 적용해 단변량 누적확률분포를 계산하여 재현기간을 도출하였다. 이변량 빈도해석에 Clayton Copula 함수를 적용하여 가뭄빈도해석을 진행하였고, Copula 이변량 재현기간과 SDF곡선을 도출하였다. Clayton Copula를 이용한 이변량 가뭄빈도해석의 결과로 소양강댐의 가장 극심한 가뭄은 1996년으로 단변량 재현기간은 지속기간 기준 9.11년, 누적부족량 기준 17.26년, Copula 재현기간은 141.19년 이며 충주댐의 가장 극심한 가뭄은 2014년으로 단변량 재현기간은 지속기간 기준 17.76년, 누적부족량 기준 18.72년, Copula 재현기간은 184.19년으로 단변량 가뭄빈도해석을 통한 재현기간보다 Copula 재현기간이 높은 결과가 도출되었다. Run 시계열을 바탕으로 한 기준유량의 임계값 기준 Event 산정과 Copula를 이용한 빈도해석은 가뭄분석에 이용되는 자료의 상관관계와 분포특성을 재현하는데 효과적인 특징이 있다. 이를 미루어 보아 Copula 함수를 이용한 가뭄빈도해석의 재현기간은 보다 현실적인 재현기간을 도출할 수 있는 것으로 판단된다. 임계값의 조정을 통해 가뭄빈도해석의 변수의 양이 늘어나면, 보다 정확도 높은 재현기간을 도출하여 수문학적 가뭄을 정의할 수 있을 것이라고 사료된다.

  • PDF