Differential Diagnosis of Benign and Malignant Thyroid Nodules Using the K-TIRADS Scoring System in Thyroid Ultrasound (갑상샘 초음파 검사에서 K-TIRADS 점수화 체계를 사용한 양성과 악성 갑상샘 결절의 감별진단)

  • An, Hyun;Im, In Cheol;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.201-207
    • /
    • 2019
  • This study has evaluated whether the method of using the combination of different risk group, according to K-TIRADS classification and K-TIRADS classification in thyroid ultrasonography is useful in a differential diagnosis of benign and malignant nodules. The subject was patients underwent thyroid ultrasonography and retrospective analysis were performed based on the results of fine needle aspiration cytology. A chi-square test was performed for the difference analysis of the score system in K-TIRADS and different risk group according to the benign and malignant of thyroid nodule. The optimized cut off value was determined by the K-TIRADS score and different risk group to predict malignant nodule through ROC curve analysis. In the differential verification result of K-TIRADS and different risk group, according to the classification of benign and malignant nodule group each showed significant difference statistically(p=.001). In the point classification according to K-TIRADS for the prediction of benign and malignant in ROC curve analysis showed AUC 0.786, Cut-off value>2(p=.001), and in the different risk group, it was decided as AUC 0.640, Cut-off value>2(p=.001). When discovering the nodule in thyroid ultrasound, it is considered that the K-TIRADAS which helps in identifying benign and malignant thyroid nodules, it is considered to be helpful in the differential diagnosis of thyroid nodules, than the classification system according to Different risk group, and when applying the classification system according to K-TIRADS, it is considered that it can reduce unnecessary fine needle aspiration cytology and could be helpful in finding the malignant nodules early.

Optimal Ambient Illumination Study for Soft-Copy Ultrasound Images (소프트 카피 초음파 이미지를 보기 위한 최적의 주변광 조도 연구)

  • An, Hyun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.209-216
    • /
    • 2019
  • The purpose of this study was to suggest the optimum ambient illumination level for proper visualization in image inspection and reading on CRT and LCD monitors used for ultrasound and reading. The evaluators were divided into 4 groups: 20 (Ultra-sonographer: 20 groups (4 groups: ultra-sonographer, 1-5 years, 5 ultra-sonographers, 6 to 10 years, 5 ultra-sonographers, 11 to 15 years, The subjects were 32 questions. The evaluation method was image evaluation of ultrasonic soft copy images for 30 seconds per 10, 25, 100Lux ambient illumination. The evaluation results were evaluated as 6 points (Normal = Definitely no lesion), 2 points = possibly not a lesion, 3 points = probably not a lesion, 4 points = possibly a lesion, 5 points = probably a lesion, 6 points = Definitely a lesion). In this study, the results of ROC analysis according to ambient light illumination reading softcopy images used for lesion detection of all ultrasound images showed the highest sensitivity, specificity, and AUC results at 10Lux. It was found that optimal use of 10Lux for ambient light illumination would provide optimal detection of lesions in ultrasound soft copy images. Based on the future research data, it will be presented as basic data for designing ambient light brightness of ultrasound imaging laboratory and reading room.

Public Cognition and Information Acquisition Route for Heavy Metals and Organic Solvents in General Population of Korea (한국인의 중금속과 유기용제에 대한 인식도와 정보취득 경로)

  • Lee, Chae Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 2021
  • Objectives: This study aimed to investigate the public cognition and information acquisition route for heavy metals and organic solvents in the general population in order to provide information for the development of public relations materials. Methods: The study was carried out by questionnaire from January to March 2011 by an interview with trained surveyors. There were 700 participants, divided by gender and age. A questionnaire was issued consisting of subjective and objective cognition evaluation items and questions about information acquisition route and preferred information acquisition route for six heavy metals and five organic solvents. Data were expressed as a percentage using the SPSS 23.0 software package. Result: For heavy metals, subjective and objective cognition degrees were higher in the order of lead, mercury, cadmium, and arsenic. They were higher among males than females, and in adults compared to school-age subjects. For organic solvents, both cognition degrees were high in the order of acetone, benzene, and formaldehyde. However, cognition degree by gender and age showed a complex pattern. As a response to information acquisition route, broadcast media had the highest in all ages and genders, followed by word of mouth from neighbors in elementary school children, school education or expert lectures in middle and high school students up to people in their 30s, and print media among those in their 40s to over 60s. There was no difference in the order by gender. As a response to preference for information acquisition route, broadcast media also proved the highest in all ages and genders, followed by school education or professional lectures among those in elementary school and over their 60s, and the internet in other age groups. Females preferred school education or expert lectures and word of mouth from neighbors, while males preferred the internet. In the case of the internet, the ranking was higher for preferred information acquisition route compared with the ranking for information acquisition route. Conclusions: This data on cognition degree, information acquisition route, and preferred information acquisition route according to gender and age can provide basic data for the development of educational and promotional materials for heavy metals and organic solvents exposure management.

Differences in Temporary Threshold Shift and Recovery Patterns Depending on Sound Type and Pressure (소리의 종류와 크기에 따른 일과성 청력 역치 상승과 회복의 차이)

  • Lee, Chae Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.387-393
    • /
    • 2020
  • Objective: This study aimed to investigate the differences in temporary threshold shift (TTS) and recovery patterns according to different types of sound and volume. Methods: TTS and recovery patterns were assessed for eight students after 30-minute exposure to both 70.0 dB and 90.0 dB of factory noise (noise) as well as music. TTS was measured before exposure and two minutes post exposure, and recovery patterns were evaluated every 10 minutes for one hour. The subjects performed activities of daily life and sleeping times as usual but taking drugs or drinking alcohol were prohibited. The experiment was repeated three times with an interval of at least 16 hours. ANOVA and T-test were carried out using SPSS 19.0 for Windows. Results: The hearing threshold of all subjects before exposure was less than 30 dB at all frequencies. Mean TTSs of 70 dB noise and 90 dB noise exposure were 0.14 and 4.48 dB (p<0.001). Meanwhile, the difference in music was insignificant (-0.63 dB and 0.55 dB, p=0.063). A significance in the difference was also found between the mean TTS of music and noise exposure, more obviously at 90.0 dB (p<0.001) than at 70 dB (p=0.232). The TTS differences were found frequency-wise in terms of sound type. Mean TTS by frequency was higher at 4,000 and 6,000 Hz than at other frequencies, and higher in noise than music at the same sound pressure. The TTS difference in each frequency between both sound types was significant at 90 dB (p<0.001). Subjects mostly recovered from TTS in one hour after exposure, but not with 90 dB-noise exposure. Conclusion: TTS and recovery patterns were different depending on the sound type. When exposed to factory noise, TTS was greater and recovery time was longer compared to music at the same sound pressure. These results suggested that the difference in cognitive processes and psychological factors according to the type of sound causes a change in TTS and recovery.

Performance Evaluation of Lead (II) Oxide Dosimeter for Digital Quality Assurance in Brachytherapy (방사선 근접치료의 디지털 정도관리를 위한 Lead (II) Oxide 선량계 성능 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.429-435
    • /
    • 2021
  • In intracavitary radiotherapy, incorrect location of the source can cause excessive dose to normal tissue, so it is essential to evaluate the location accuracy of the source. In this study, basic research was performed on digital line dosimeter based on lead (II) oxide (PbO) to improve analog verification method. Therefore, a polycrystalline PbO unit cell dosimeter was manufactured and the measurement performance for Ir-192 sources was evaluated. As a result, the reproducibility satisfies the evaluation criteria of 1.5% with a relative standard deviation of 0.85%. Linearity showed excellent results with a linear coefficient of R2 of 0.9998. In the case of distance dependence evaluation, the power function R2 showed 0.9855 for PbO and 0.9974 for diode, and the overall average difference was 1.66% for PbO and 2.18% for diode. This study presents the basic detection performance of the polycrystalline PbO dosimeter for the Ir-192 source and can provide basic data in the field of radiation measurement.

Evaluation of Applicability of Perovskite Dosimeter based on CsPbBr3 Material to Quality Assurance in Radiation Therapy (CsPbBr3을 기반으로 한 Perovskite 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2022
  • In radiation therapy, accurate Quality Assurance (QA) is required to irradiate tumor tissue while minimizing damage to normal tissue. Therefore, a dosimeter that can accurately measure radiation is needed. The purpose of this study is to develop a highly efficient radiation dosimeter with high sensitivity by applying a particle in binder method that can reduce manufacturing costs and simplify processes to perovskite materials that are cheaper and simpler to manufacture. By evaluating the response characteristics to high-energy photon, the applicability of QA dosimeter to radiation therapy was evaluated. As a result of reproducibility evaluation, RSD at 6 MV energy was presented as 1.178% and 15 MV energy was presented as 1.141%. As a result of linearity evaluation according to linear regression analysis, R2 values of 0.9999 were presented under each condition of 6 MV and 15 MV energy. It was found that the CsPbBr3 dosimeter manufactured based on the results of reproducibility and linearity evaluation is highly applicable as a QA dosimeter in the field of therapeutic radiation. The CsPbBr3 dosimeter manufactured in this study presented more than the standard performance in the evaluation of reproducibility and linearity, and it can be used as a radiotherapy QA dosimeter through improvement.

Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters (전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.513-518
    • /
    • 2022
  • Electron beam quality assurance (QA) should be done regularly for accurate radiation therapy. However, QA tools used in clinical practice are designed mainly for X-rays. So, a dosimeter for electron beam QA is required. Therefore, in this study, the electron beam detection performance was measured by using a thorium bromide material as an electron beam sensor. In addition, it was evaluated whether it could be applied with an electron beam QA dosimeter. Reproducibility, linearity, and dose rate dependence were evaluated at 6 MeV and 9 MeV energies. As a result of reproducibility, it showed a maximum output change of 0.92% at 6 MeV and 1.15% at 9 MeV. The linearity result evaluation and determination coefficient were presented as 0.9998. As a result of dose rate dependence evaluation, relative standard deviation 0.51% at 6 MeV and relative standard deviation 1.07% at 9 MeV were presented. The manufactured TlBr sensor shows the ability to detect radiation that meets the criteria for evaluation of reproducibility, linearity, and dose rate dependence. These results mean that the TlBr dosimeter is applicable as an electron beam QA dosimeter.

Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy (근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.405-410
    • /
    • 2022
  • In brachytherapy, a radiation source is inserted into the body to kill tumor tissue. Therefore, it is important to accurately measure the location of the source and the dose distribution. In this study, a dosimeter that can be used for brachytherapy was developed using CsPbBr3 which is cheaper than the existing detector materials and has a simpler manufacturing process. The CsPbBr3 dosimeter performance was evaluated by analyzing reproducibility, linearity, and distance dependence in 192Ir source. As a result of reproducibility evaluation, the RSD was 1.36%, which satisfies the standard value of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the standard R2 of 0.9990. The distance dependence evaluation showed a signal value that decreased exponentially as the distance increased. The evaluation results show that the CsPbBr3 dosimeter satisfies the evaluation criteria and can be used as a brachytherapy quality assurance dosimeter.

Clustered Microcysts Detected on Breast US in Asymptomatic Women (무증상 여성의 유방초음파에서 발견된 군집 미세낭종)

  • Hyun Jin Kim;Jin Hwa Lee;Young Mi Park;Kyungjae Lim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.676-685
    • /
    • 2023
  • Purpose To investigate the incidence, outcomes, and imaging characteristics of clustered microcysts detected on breast US in asymptomatic women, and suggest appropriate management guidelines. Materials and Methods We identified and reviewed the lesions recorded as "clustered microcysts" on breast US performed in asymptomatic women between August 2014 and December 2019. The final diagnosis was based on pathology and imaging follow-up results for at least 12 months. Results The incidence was 1.5% and 100 patients with 117 lesions were included. Among 117 lesions, 3 (2.6%), 2 (1.7%), and 112 (95.7%) were malignant, high-risk benign, and benign lesions, respectively. The malignant lesions included two cases of ductal carcinoma in situ and one invasive ductal carcinoma. Two of them were assessed as category 4, showing mammographic suspicious microcalcifications and internal vascularity on Doppler US. The remainder was a false negative case and showed echo pattern change on the 12-month follow-up US. Conclusion The incidence of clustered microcysts on breast US in asymptomatic women was 1.5% and malignancy rate was 2.6% (3 of 117). Knowledge of outcomes and imaging features of benign and malignant clustered microcysts may be helpful for radiologists, thereby aiding categorization and management recommendations.

Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery (버니 다초점인공수정체의 임상적 효용성)

  • Cho, Myung Ho;Park, Jae Yeong;Park, Byung Gun;Lee, Jong Soo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1129-1136
    • /
    • 2018
  • Purpose: To compare the postoperative clinical outcomes after cataract surgery and implantation using the BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ multifocal intraocular lenses. Methods: Sixty-five eyes implanted with multifocal intraocular lenses were divided into two groups involving either $ReSTOR^{(R)}$ (39 eyes) or BunnyLens $MF^{(R)}$ (26 eyes) lenses. In these two groups, the distant and near visual acuity, astigmatism, spherical equivalent, and contrast sensitivity test were examined at preoperative and postoperative 1 week, 8 weeks, and 24 weeks. We compared the clinical efficacy between the two groups before and after cataract surgery using statistical analysis. Results: The mean value of distant and near visual acuity, and spherical equivalent of both groups after intraocular lens implantation were significantly improved, compared with the preoperative values (p < 0.05), while there was no significant differences between the two groups (p > 0.05). The means of postoperative distant and near visual acuity, astigmatism, and contrast sensitivity test were not significantly different between $ReSTOR^{(R)}$ and BunnyLens $MF^{(R)}$ lenses (p > 0.05). The mean numeric error of spherical equivalent at the final postoperative 24 weeks was $-0.17{\pm}0.50$ diopters (D) for the $ReSTOR^{(R)}$ lenses and $-0.34{\pm}0.52D$ for the BunnyLens $MF^{(R)}$ lenses (p > 0.05). Conclusions: BunnyLens $MF^{(R)}$ and $ReSTOR^{(R)}$ lenses showed no significant difference in clinical efficacy, including distance and near vision, spherical equivalent error, and contrast sensitivity test after cataract surgery. However, it should be noted that BunnyLens $MF^{(R)}$ lenses had a tendency toward myopic shift compared with $ReSTOR^{(R)}$ lenses.