• 제목/요약/키워드: 부분절연

검색결과 363건 처리시간 0.039초

결함별 절연유중 부분방전 측정 연구 (PD Measurement in oil with defects)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.67-69
    • /
    • 2004
  • Since partial discharges in power transformers weaken their insulation performance the detection of partial discharge is very important for prevention of fatal incidents. This study describes use of electromagnetic coupler for measurement of partial discharge of transformers. Spiral antennas of which bandwidth is 0.5GHz to 3GHz were used as coupler and setup in chamber for partial discharge tests. Test results showed that outputamplitudes are increased with PD increase and frequencies of signal measured by these antennas are mostly distributed below about 800MHz.

  • PDF

액체$N_2$중 절연재료의 부분방전 열화 연구 (Study of Partial Discharge Degradation of Insulating Materials in Liquid Nitrogen)

  • 김현희;김상현;마대영;장종근;남궁도;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.406-410
    • /
    • 1995
  • A superconducting cable is one of the promising methods of undground transmission of high electric power in the future. It is very important that composite insulation system of $LN_2$ and polymer films takes into consideration for application high $T_c$ superconductor. This study is about both the partial discharge and properties V-t in $LN_2$. As result, applied voltage doesn't depend on the radius of non-eroded area but eroded area. And eroded area is observed the formation such as the ring of a tree.

  • PDF

부분방전을 이용한 초고압 지중 송전 절연 케이블 내부 결함의 패턴분석 (Pattern Analysis of the Defects within the Cable Insulation for UHV Underground Transmission Using Partial Discharge)

  • 박재화;이광열;채석;오영석;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.175-179
    • /
    • 1998
  • The insulation of cable which used for Ultra-High Voltage(UHV) underground power transmission requires excellent insulation capability for high voltage. The typical insulation materials are used XLPE, EPR, etc, but insulation efficiency of these is affected by void or alien substances, existed at the inside of insulators. In this paper, the partial discharge patterns of the defects within insulation cable are observed and analyzed. In this test, void, fiber and metal inclusions which possibly exist in cables, are simulated and investigated the patterns of partial discharges for each models Also the relations between calculated field strength and the insulation breakdown voltage. The experiment shows distinct partial discharge patterns in accordance with the kinds of defects within Insulation cable.

  • PDF

직렬 연결 고주파 변압기를 가지는 교류/직류 전력변환 회로 (Series-connected Universal Link AC/DC Power Converter with High-Frequency Transformer)

  • 유안노;김명호;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.374-375
    • /
    • 2010
  • 본 논문에서는 계통 연계가 가능한 새로운 교류/직류 전력변환 장치를 제안한다. 제안된 전력변환 회로는 정현파의 입력상 전류를 가지고, 양방향 전력 전달이 가능하며, 역률 제어가 가능하다는 장점으로 인하여 계통 연계형 전력변환 장치로 적합하다. 특히 제안된 전력변환 장치는 무효전력 소자의 사용을 최소화하여 시스템의 신뢰성을 증대시키고, 전기적 절연을 고주파 변압기를 통하여 얻도록 하여 시스템의 부피를 줄일 수 있다는 장점을 갖는다. 본 논문에서는 제안된 전력변환 회로의 구성 방법과 각 부분 별 동작에 대해서 기술하였으며 실험 장치를 구성하여 그 타당성을 입증하였다.

  • PDF

EMI필터가 아크사고검출에 미치는 영향 분석 (Analysis of EMI filter effect in Arc-Fault detection)

  • 최수경;권완성;김종민;방선배;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-120
    • /
    • 2010
  • 일반적으로 전선이 낡고 오래되거나 또는 강한 열이나 외부적 충격 등에 의해서 절연이 파괴된 경우 전기화재의 원인이 되는 아크 현상이 발생한다. 이러한 아크 사고는 Arc Fault Circuit Interrupter (AFCI)를 통해 예방할 수 있다. UL1699규정은 AFCI의 성능 시험을 위한 규정으로 구체적인 여러 성능 시험을 제시하고 있다. 그 중 EMI 필터 시험에 대한 부분을 한국의 전기 배선에 맞게 재구성하여 실험하고, 아크 검출에 EMI 필터가 어떤 영향을 미치는지 분석하여 UL에서 제시한 EMI 필터 시험의 타당성을 검증한다.

  • PDF

가스절연기기 내부의 금속 이물질에 의한 초고속 부분방전량 및 전류 측정 (Ultra-fast meseurement of partial discharge current due to conducting particle in Gas-insulated System (GIS))

  • 박기준;구선근;윤진열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.160-164
    • /
    • 2002
  • A special discharge cell containing a free conducting particle was used to generate the discharges in $SF_6$. The analog bandwidth of the measurement system exceeded 5 GHz. The measured signals were processed to compensate for the response of the measurement system. The discharge current rise time was in the range of 70 ps, while its full-width half-maximum was 120 ps. Single and double current pulses of positive and negative polarities were measured. Likewise, these pulses were compared with the measurement obtained using a conventional partial discharge detector of the IEC60270 type

  • PDF

고전압 절연재료의 결함진단을 위한 부분방전측정 (The Measurement of Partial Discharge to Diagnose Defects in High-Voltage Insulating Materials)

  • 이정빈;정우성;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.134-138
    • /
    • 1994
  • According to request of insulating materials for high-voltage, recently we make effort not only to develop diagnostic skills of aging state but also to discover defects in insulating material in the early. Especially, partial discharge has been actively studied as a non-destructive diagnosis technique and very useful method. Because the method of partial discharge measurement has damages less than other conventional diagnosis technique. In this paper, the characteristics of partial discharge was investigated and studied on many samples with voids. In order to adapt as a practical diagnosis technique, it is studied on the characteristics of partial discharge and insulation breakdown in the high voltage. We suggest that partial discharge measurement can be used in order to diagnose defects in high-voltage insulation materials.

발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발 (Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF

송전 XLPE 케이블 절연층을 이용한 전기트리 형성과 부분방전 양상의 상관관계 (A study on the correlation between the PD pattern and the formation of electrical trees by use of XLPE insulation for the underground power transmission cable)

  • 이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2051-2053
    • /
    • 1999
  • In this work, PD patterns and electrical trees are observed by use of the XLPE cable insulation. and the tree initiation voltage related to the contamination are also measured in order to calculate the electric stress necessary for the design of cable insulation. Throughout these works, correlation between the PD pattern and the shape of electrical tree has been observed that there may exist three distinct pattern of PD dependence on the stage of tree propagation, Such correlation could bring a basic information in connection with the partial discharge of cable system. It was also found that the electrical stress necessary for the initiation of electrical tree was measured to the 290kV/mm for the 154kV XLPE cables manufactured in KOREA.

  • PDF

고체절연체 계면에서 부분방전 패턴의 열화에 따른 변화특성 (The Characteristics of PD Patterns due to the Aging at the Interface between Solid Insulators)

  • 이우영;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1725-1727
    • /
    • 1998
  • In this paper the patterns of partial discharges(PD) occurred from some defects at the interface of cable joints as the function of the phase of the applied voltage were investigated in order to discern the kind of a defect. The results obtained in this study show that it is possible to distinguish the PD patterns between the void discharges and the treeing or tracking discharges which were occured at the cable joint interface. While the state of defect transfers from a void discharge into a tree or tracking discharge with a aging time, the skewness for both half of the applied voltage cycle is observed to go to the negative value.

  • PDF