• Title/Summary/Keyword: 봄베열량계

Search Result 4, Processing Time 0.016 seconds

An Experimental Study on the Developement of Bomb Calorimeter (발열량 측정장치 개발에 관한 연구)

  • Lee, Dong-Je;Son, Young-Mog;Kang, Han-Saem;Kim, Hyung-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.23-30
    • /
    • 2001
  • Bomb calorimeter was developed for measuring the calorific value of combustible matter such as wastes. The calorimeter consist of bomb, stirred-water type bucket, thermometer and ignition circuit. Operation and performance of the calorimeter have been tested experimentally. In the present study, calorific values of light oil, lamp oil, benzoic acid, ethyl alcohol and methyl alcohol is measured using the bomb calorimeter. Mass of the sample is fixed at 19, and oxygen pressure in the bomb is used as an experimental parameter. Sample in the oxygen bomb is burned with electrically heated Ni-Cr wire of 100mm in length, and temperature of water in the bucket become increased by $2{\sim}5^{\circ}C$ during about 30min. Calorific value of the sample is calculated with the temperature difference of water. Combustion tests, such as the record of temperature history and the inspection of remnants, are performed at 6, 8 and 10 atm of the oxygen pressure. From the test results, oxygen pressure in the bomb must be over 10atm for complete combustion.

  • PDF

An Experimental Study on the Developement of Bomb Calorimeter (발열량 측정장치 개발에 관한 연구)

  • Kim, Hyung-Man;Son, Young-Mog;Lee, Dong-Je
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.60-65
    • /
    • 2001
  • Bomb calorimeter was developed for measuring the calorific value of combustible matter such as wastes. The calorimeter consist of bomb, stirred-water type bucket, thermometer and ignition circuit. Operation and performance of the calorimeter have been tested experimentally. In the present study, calorific values of light oil, lamp oil and bunker C oil is measured using the bomb calorimeter. Mass of the sample is fixed at lg, and oxygen pressure in the bomb is used as an experimental parameter. Sample in the oxygen bomb is burned with electrically heated Ni-Cr wire of 100mm in length, and temperature of water in the bucket become increased by $5^{\circ}C$ during about 30min. Calorific value of the sample is calculated with the temperature difference of water. Combustion tests, such as the record of temperature history and the inspection of remnants, are performed at 4, 6, 8 and 10 atm of the oxygen pressure. From the test results, oxygen pressure in the bomb must be over 10atm for complete combustion.

  • PDF

Thermal Stability and Critical Ignition Temperature of RPF (RPF의 열적 안정성과 한계발화온도)

  • Lim, Woo-Sub;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.99-104
    • /
    • 2008
  • It is important to understand thermal characteristic as a method to estimate the new materials, because spontaneous ignition characterized by causing combustion in the low temperature without ignition source. If can not find out the thermal characteristics of materials, it is frequent that causes of fires could not be found. The danger level of spontaneous ignition material should be estimated and by closely studying its thermal characteristic. However, RPF(Refuse Paper & Plastic Fuel) is a solid matter and getting increasesa year by year because it is an economy profit as alternative energy for limited fossil fuels. Some time RPF occur a fire in the cases of its production process and conservation. Therefore study for thermal stability and critical ignition temperature of RPF was so imperative that the experiment by means of Bombe Calorimeter, TG-DTA, MS80, SIT-II, and Wire Basket Test was implemented. As a result, RPF had a caloric value 26.4-28.3 MJ/kg, and its initial pyrolysis temperature was $192^{\circ}C$ at heating rate 2 K/min. With the result of analysis by MS 80 which is an instrument measuring microscopic calory, pure RPF not containing water has higher caloric value than RPF containing 20% water. Also, SIT-II which is an instrument of insulated auto-ignition was ignited by $118.5^{\circ}C$. This temperature is lower than that of Wire Basket Test. The critical ignition temperature was calculated by Frank-Kamenetskii equation can cause ignition at $80^{\circ}C$ when conserved in the height of 10 m by the standard of infinity slab.

A Study on the Characteristics of Combustion and Manufacturing Process on Refuse-derived Fuel by Mixing Different Ratios with Organic and Combustible Wastes (유기성폐기물 고체연료화를 위한 연소 및 제조과정의 특성연구)

  • Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • To investigate the feasibility of refuse derived fuels (RDFs) combined of sewage sludge and combustible wastes such as substitutive fuels instead of a stone coal, several different RDFs made with different mixtures of sewage sludge and combustible wastes were analyzed by various experiments. The combustion characteristics for the RDFs were investigated by analyzing fuel gases, and heating values were also measured by a bomb calorimeter. The fundamental properties such as moisture contents, ratios of combustible materials, amounts of ashes, heavy metals, ratios of each chemical elements and heating values were analyzed in accordance with mixing ratios of wt(%) for researching the characteristics of the RDFs. $RDF_{k-1}$ was made of mixing materials which were dried sewage sludge, food wastes and combustible wastes. $RDF_{k-2}$ was made of mixing materials which were peat-moss, tar and sewage sludge. Combustion experiments were carried out at the optimal conditions which were m=2 under air-fuel condition and $850^{\circ}C$. The retention times in the combustor were set at 5, 10 and 15minutes. 50 g of RDFs was put in the combustor for each experiments. The ranges for heating values of $RDF_{k-1}$ with different mixing ratios were from 6,900 kcal/kg to 8120 kcal/kg. The ranges for heating values of $RDF_{k-2}$ with different mixing ratios were from 4,014 kcal/kg to 8,050 kcal/kg. As a result of this study, the heating values, moisture contents, components of chemical elements and mixing ratios of the materials in RDFs had big effects on the efficiency of the combustion. In $RDF_{k-1}$, the higher amounts of combustible wastes in the mixtures, the higher heating values, concentrations of $C_xH_y$ and amounts of ashes were produced. In $RDF_{k-2}$, the higher tar amounts in the mixtures caused the higher heating values, amounts of ashes, concentrations of CO gas and CxHy.