• Title/Summary/Keyword: 볼트 결합부

Search Result 41, Processing Time 0.024 seconds

The Experimental Study on Load Transfer Mechanisms in Non-slip Device of Steel Pipe Pile Cap (강관말뚝 머리결합부의 미끄럼 방지턱에 관한 하중전달 메카니즘 연구)

  • Kim, Young-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.221-229
    • /
    • 2004
  • In Recent experimental research results of connection method between steel pipe pile and concrete footing are provided based on various experimental observations. It gives a shedding light toward developing better connection method for steel pipe pile at the field application. In this study, the newly developed method is tested for compressive, pull put and combination load including moment with carefully designed monitoring system. The measured data show that new method have at least equivalent or better load resistant capacities compared with those of specified method in Korea Road Design Specification. It is also tried to define and investigate the load transfer mechanism for new method.

Finite Element Modeling for Static and Dynamic Analysis of Structures with Bolted Joints (볼트결합부를 포함한 구조물의 정적 및 동적 해석을 위한 유한요소 모델링)

  • Gwon, Yeong-Du;Gu, Nam-Seo;Kim, Seong-Yun;Jo, Min-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.667-676
    • /
    • 2002
  • Many studies on the finite element modeling for bolted joints have proceeded, but the structures with bolted joints are complicated in shape and it is difficult to find out the characteristics according to joint condition. Usually, experimental methods have been used for bolted joint analysis. A reliable and practical finite element modeling technique for structure with bolted joints is very important for engineers in industry. In this study, three kinds of model are presented; a detailed model, a practical model and a simple model. The detailed model is modeled by using 3-D solid element and gap element, and the practical model is modeled by using shell element (a portion of bolt head) and beam element (a portion of bolt body), the simple model is modeled by simplifying practical model without using gap elements. Among these models, the simple model has the least degree of freedom and show the effect of memory reduction of 59%, when compared with the detailed model.

Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading (반복하중을 받는 하이브리드 프리캐스트 보-기둥 접합부의 성능평가)

  • Choi, Hyun-Ki;Yoo, Chang-Hee;Choi, Yun-Cheul;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.325-333
    • /
    • 2010
  • In this study, new moment-resisting precast concrete beam-column joint made up of hybrid steel concrete was developed and tested. This beam-column joint is proposed for use in moderate seismic regions. It has square hollow tubular section in concrete column and connecting plate in precast U-beam. The steel elements in column and beam members were connected using bolt. Furthermore, in order to prevent the premature failure of concrete in hybrid steel-concrete connection, ECC(engineered cementitious composite) was used. An experimental study was carried out investigating the joint behavior subjected to reversed cyclic loading and constant axial compressive load. Two precast beam-column joint specimens and monolithic reinforced concrete joint specimen were tested. The variables for interior joints were cast-in-situ concrete area and transverse reinforcement within the joint. Tests were carried out under displacement controlled reverse cyclic load with a constant axial load. Joint performance is evaluated on the basis of connection strength, stiffness, energy dissipation, and displacement capacity. The test results showed that significant differences in structural behavior between the two types of connection because of different bonding characteristics between steel and concrete; steel and ECC. The proposed joint detail can induce to move the plastic hinge out of the ECC and steel plate. And proposed precast connection showed better performance than the monolithic connection by providing sufficient moment-resisting behavior suitable for applications in moderate seismic regions.

Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall (프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발)

  • Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.435-442
    • /
    • 2017
  • A lateral load resisting system is a necessary structural element for the mid- to high-rise modular buildings and concrete cores are known as the most typical lateral load resisting systems in 10- to 20-story modular buildings. It is difficult to construct a concrete core simultaneously with the installation and finishing work of modular units because concrete placed using wet methods might contaminate or destroy the modular unit. Therefore, we have developed a hybrid PC (precast concrete) panel construction method that can construct a concrete core together with the installation of modular units. The hybrid PC panel is a load-bearing element in which a pair of C-shaped beams are combined at the top and bottom of a concrete wall. Concrete cores can be constructed by dry method to connect the hybrid PC panels with bolts. In this study, the details and connection of hybrid PC panels are improved to have the lateral performance comparable to reinforced concrete structural walls and are verified through FE analysis.

The Structural Characteristics of Non-slip Device in Connecting Method Between Steel Pipe Pile and Footing (미끌림 방지턱을 이용한 강관말뚝 머리 결합부의 구조특성에 관한 실험적 연구)

  • 박영호;김낙영
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.227-243
    • /
    • 2003
  • To find the structural characteristics of non-slip device in connecting method B between steel pipe pile and concrete footing, compression and uplift test was performed for full sized specimens not having non-slip device, those having non-slip device with two curved steel plate bars welded inside the steel pipe pile(standard method), and those having non-slip device with serveral curved steel plate bars bolted inside the steel pipe pile(new method). As a result, specimens not having non-slip device had chemical debonding failure at 15.6tonf of peak uplift load and 27.57tonf of peak compression load. And the standard method and the new method showed about 8.9 times of peak uplift load and 6.2 times of peak compression load higher than specimens not having non-slip device. The load transfers of lower non-slip devices of the standard method and the new method were similar in behavior, while the higher non-slip device of the new method showed higher ratio of load transfer than that of the standard method. And these two methods had nearly the same composite action and structural capacity caused by non-slip devices.

Effect of Filled Hole on Strength Behavior of CFRP Composites at Cold Temperature Dry and Elevated Temperature Wet (저온건조($-55^{\circ}C$) 및 고온다습 조건($108.3^{\circ}C$)의 기계적 체결 홀이 탄소섬유강화 복합재의 강도 특성에 미치는 영향 연구)

  • Kim, Hyo-Jin
    • Composites Research
    • /
    • v.22 no.3
    • /
    • pp.82-88
    • /
    • 2009
  • The effect of open and filled holes on the strength behavior of carbon fiber reinforced polymeric (CFRP) composites was investigated. The strength was measured at room temperature dry, cold temperature dry, $-55^{\circ}C$, and elevated temperature wet, $108.3^{\circ}C$ on several different laminate configurations. Based on the experimental data presented, it is shown that the filled hole tensile strength is larger than that of open hole by reducing damage around the hole due to the constraint imposed by the fastener. The tensile strength at cold temperature dry, $-55^{\circ}C$ is increased with the brittleness by the thermal expansion coefficient of fiber and matrix. The compressive strength at elevated temperature wet, $108.3^{\circ}C$ is decreased by the cause of interfacial deterioration between fiber and matrix with moisture absorption.

State-of-the-art Node of Freeform Structure (프리폼 구조의 노드 기술 현황 분석)

  • Lee, Kyoung Ju;Oh, Jin Tak;Kim, Sang Dae;Ju, Young Kyu
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.153-153
    • /
    • 2011
  • 현대 건축은 기능적이고 합리적이었지만 획일적이었던 박스형 건축에서 탈피해 형태와 공간에 있어서 다양한 변화를 시도하고 있다. 특별한 건축물의 실현을 위해 각 나라의 기술력은 급속한 발전을 이루었고, 보다 더 독특한 건축물에 대한 관심은 비정형 건축물에 대한 관심의 증대로 이어지고 있다. 이러한 비정형 건축물에 적합한 구조로써 프리폼(Free-Form) 구조가 있다. 프리폼 구조로 입체골조(Double Layered Structure)를 많이 사용하였으나, 최근 유리로 되어 투명하고 기하학적 모양의 건축물을 추구함에 따라 평면골조(Single Layered Structure)가 증가하고 있는 추세이다. 평면골조는 축력 지배형과 모멘트 지배형으로 분류할 수 있고 프리폼 구조의 구성 요소 중 가장 취약하고 중요한 부분은 노드이다. 본 연구에서는 프리폼 구조 중 가장 큰 관심이 고조되고 있는 평면골조 모멘트 지배형의 노드에 대한 국내외 기술 분석을 통해 향후 연구 방향성을 제시하고자 한다. 입체골조는 하나의 노드에 여러개의 부재가 3차원으로 결합되어야 하기 때문에 다른 골조 시스템에 비해 노드부가 복잡하지만, 건축물의 외관을 유리로 하여 투명하게 하고 비틀리고 구부러진 구조물에 대한 건축적 요구가 많아짐에 따라 평면골조의 인기가 높아지고 있다. 이러한 시대의 흐름에 발맞추어 건물의 구조적, 기하학적 요구를 충족시키기 위해 다양한 노드 시스템이 개발 중이며, 가해지는 하중의 특성에 따라 축력 지배형과 모멘트 지배형으로 구분하여 노드의 양상을 분류할 수 있다. 축력 지배형의 대표적인 시스템은 다이아그리드(Diagrid)이다. 축력 지배형 프리폼 구조의 노드는 전체 구조물의 하중을 축력으로 받아 모두 전달해야 하기 때문에 크기가 크고 가새가 2~4개층에 걸쳐서 설치되기 때문에 중량이다. 모멘트 지배형 노드를 갖는 프리폼 구조의 형태는 대부분 지붕 구조로써 지붕 자체의 하중만을 견디도록 설계된다. 따라서 노드부와 노드에 붙는 부재들이 가볍기 때문에 사람이 들 수 있고 노드의 크기가 작아 시공성이 좋으며 대량 생산이 가능하다는 장점이 있다. 노드의 형태는 힘의 흐름과 쓰임에 따라 다양하다. 평면골조 모멘트 지배형의 노드는 접합방식에 따라 Splice node connection과 End-Face node connection 두 가지로 분류할 수 있다. Splice node connection은 각 부재의 종축으로 노드와 구조부재 사이에 이음재를 두어 연결하고, 연결 형태에 따라 전단력을 전달할 수 있는 1~2개의 접촉면이 생긴다. 전단응력을 받는 볼트로 이음재를 이어 조립하거나 용접으로 접합할 수 있다. 대표 노드로, SBP-1, SBP-2와 POLO-1 등이 있다. End-Face node connection은 각 연결된 부재의 단부와 노드 사이의 연결면은 종축방향의 수직이고, 인장응력을 받는 볼트를 사용하거나 용접에 의해 접합할 수 있다. 대표 노드로 SBP-4, WABI-1, MERO-1(Cylinder), MERO-2(Block), MERO-4(Double Dish) 등이 있다. 본 기술 현황 분석을 통해 현재 개발된 노드를 분류하고 가장 관심이 높은 Single Layer 모멘트 지배형 노드를 비교, 분석하였다. 최근 건물의 경향을 반영한 프리폼 구조를 실현하기 위해서 필수적인 노드의 개발은 국외에서 활발히 연구되고 있지만 그 기술이 개방되어 있지 않다. 국내에서는 동대문 디자인 플라자에 새로운 노드를 적용하고 고려대학교에서 모멘트 지배형 노드를 개발하는 등 발전 가능성을 보이고 있지만 국외 사례들에 비하면 아직 초기 단계라 할 수 있다. 따라서 현장 용접을 지양하고 공장 제작하여 현장에서 조립하며, 프로젝트 별로 상이한 노드를 사용하는 것이 아닌 다양한 요구를 효과적으로 수용하는 구조 효율성을 향상시킨 노드 상세의 개발이 이루어져야 할 것이다.

  • PDF

The suggestion of Steel Plate-Concrete Composite Beam Shape with Bolts (볼트 체결형 강판-콘크리트 합성보의 형상 제안)

  • Cho, Tae-Gu;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.305-314
    • /
    • 2018
  • The steel-plate concrete composite beam is composed of a steel plate, concrete and a shear connector to combine the two inhomogeneous materials. In general, the steel plate is assembled by welding an existing composite beam. In this study, a new steel-plate concrete composite (SPCC) beam was developed to reduce the size of the shear connector and improve its workability. The SPCC beam was composed of folded steel plates and concrete, without any shear connector. The folded steel plate was assembled with high strength bolts instead of welding. To improve the workability in field construction, a hat-shaped cap was attached in the junction with the slab. Monotonic two-point load testing was conducted under displacement control mode. The flexural strength of the SPCC beam specimen was calculated to be 76% of that of the complete composite beam by using the plastic stress distribution method and strain compatibility method. The cap acted as the stud and accessory. The synthesis rate could be increased by controlling the gap of the cap, and the bending performance could be evaluated by using the strain fitting method considering the synthesis rate of the SPCC beam.

Flexural Strength Evaluation of Steel Plate-Concrete Composite Beam using Bolted (절곡 강판을 볼트로 체결한 강판-콘크리트 합성보의 휨강도 평가)

  • Han, Myoung-Hwan;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.126-136
    • /
    • 2018
  • A steel-plate concrete composite beam is composed of a steel plate, concrete and shear connector to combine inhomogeneous two materials. The steel plate is assembled by welding an existing composite beam. In this study, new steel-plate concrete composite beam, called a SPC Beam, was developed to reduce the shear connector and improve the workability. The SPC Beam was composed of folding steel plates and concrete, without a shear connector. The folding steel plate was assembled using high strength bolt instead of welding. To improve the workability in field construction, a hat-shaped Cap was attached to the junction with a slab. Monotonic load testing under two points was conducted under displacement control mode. The flexural strength of the specimen for positive moment and negative moment was calculated using the plastic stress distribution method. The test results showed that the flexural strength of the new SPC Beam had 80% of the strength of a complete composite beam. In addition, increasing the composite ratio was possible through clearance controls of the cap. In this study, the performance of the SPC Beam was verified through additional experiments and analyses with the cross-sectional shape and cap as variables, because the representative shape in the positive negative moment region is targeted.

A Study on the Lattice Girder by Increasing Contacting Area between Spider and Rod (스파이더와 강봉간 접촉면적을 증가시킨 격자지보재에 대한 연구)

  • Nam, Joong-Woo;Kim, Jin-Kyo;Cho, Yong-Gyo;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.10
    • /
    • pp.17-25
    • /
    • 2012
  • Shotcrete, rockbolt, and steel rib are installed to support ground after tunnel was excavated. These are important supports for NATM applied tunnels. Recently, lattice girder is increasingly used because it is easily installed. In this study, we developed a new lattice girder by increasing contacting area between spider and rod. To verify the effect of the new lattice girder, the 3-point and 4-point flexural strength tests were carried out for LG-$50{\times}20{\times}30$, LG-$70{\times}20{\times}30$, LG-$95{\times}22{\times}32$. As a result, in case of contacting area, strength of new SGS lattice girder is 17.95% higher than that of original lattice girder. In case of weakness point, strength of new SGS lattice girder is 19.37% higher than that of original lattice girder.