• Title/Summary/Keyword: 복합환경 부식

Search Result 82, Processing Time 0.02 seconds

Stress Corrosion Cracking Behavior of Alloy 690 in Crevice Environment (Pb + S + Cl) in a Steam Generator Tube (증기발생기 전열관 틈새복합환경(Pb+S+Cl)에서 Alloy 690의 응력부식균열거동)

  • Shin, Jung-Ho;Lim, Sang-Yeop;Kim, Dong-Jin
    • Corrosion Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The secondary coolant of a nuclear power plant has small amounts of various impurities (S, Pb, and Cl, etc.) introduced during the initial construction, maintenance, and normal operation. While the concentration of impurities in the feed water is very low, the flow of the cooling water is restricted, so impurities can accumulate on the Top of Tubesheet (TTS). This environment is chemically very complicated and has a very wide range of pH from acidic to alkaline. In this study, the characteristics of the oxide and the mechanism of stress corrosion cracking (SCC) are investigated for Alloy 690 TT in alkaline solution containing Pb, Cl, and S. Reverse U-bend (RUB) specimens were used to evaluate the SCC resistance. The test solution comprises 3m NaCl + 500ppm Pb + 0.31m $Na_2SO_4$ + 0.45m NaOH. Experimental results show that Alloy 690 TT of the crevice environment containing Pb, S, and Cl has significant cracks, indicating that Alloy 690 is vulnerable to stress corrosion cracking under this environment.

Characteristic of organic/inorganic composite formed grounding resistance lowering agents (유/무기 복합재료형 접지저감제의 특성)

  • Kim, Jang-Wook;Chung, Chul-Hee;Cho, Dae-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.74-80
    • /
    • 2004
  • Among inorganic materials, it is grounding resistance lower agent of new form that use being strata style clay and makes using water soluble polymer by main material to organic substance. Water soluble polymer chains are dispertion in water because water soluble polymer reacts with water if is done and these discrete polymer chains are inserted to floor of being strata style clay with water. This material that moisture content is very excellent and rate of expansion, electrical conductivity that measure after supplies water of 300wt % as well as is excellent. Can prevent corrosion or electrolytic corrosion of grounding bar securing very environmentally, chemically and pollution of soil. When applied to general grounding rod worker $7{\sim}8$ times ground resistance reduction effect of not application.

  • PDF

Corrosion Properties of Reinforced Concrete with Types of Surface Cover and Covering Depth under the Combined Deterioration Environments (복합열화 환경하에서 표면피복종류 및 피복두께에 따른 철근콘크리트의 부식특성)

  • Kim, Moo-Han;Kwon, Young-Jin;Kim, Young-Ro;Kim, Jae-Hwan;Jang, Jong-Ho;Cho, Bong-Suk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.119-126
    • /
    • 2004
  • Generally, reinforced concrete is one of the most commonly used structural materials and it prevents corrosion of steel bar by high pH of interior, But, as time elapsed, reinforced concrete structure become deteriorated by many of combined deterioration factors and environmental conditions. And, there are large number of deteriorate mechanism of the reinforced concrete structure and it acts complexly. It is recognized that steel bar corrosion is the main distress behind the present concern regarding concrete durability. In this study, to institute combined deterioration environments, established acceleration condition and cycle for combined deterioration environments has a resemblance to environments which are real structures placed. After that to confirm corrosion properties of reinforced concrete due to permeability with covering depth and types of surface cover under combined deterioration environments, measured carbonation velocity coefficients, chloride ion diffusion coefficients, water absorption coefficients, air permeability coefficients and electric potential, corrosion area ratio, weight reduction, corrosion velocity of steel bar. The results showed that an increase in age also decrease carbonation velocity coefficients, increase Chloride ion diffusion coefficients and increases water absorption coefficients. As well, an increase in age also increases corrosion of steel bar. Data on the development of corrosion velocity of steel bar with types of surface cover made with none, organic B, organic A, inorganic B, and inorganic A is shown. As well, permeability and corrosion velocity of steel bar with covering depth is superior to 10mm than 20mm. And it is confirmed permeability and corrosion properties of steel bar are closely related.

Cavitation damage characteristics in seawater of electroless nickel plated gray cast iron (무전해 니켈 도금된 회주철의 해수 내 캐비테이션-침식 손상 특성)

  • Park, Il-Cho;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.142-142
    • /
    • 2016
  • 무전해 니켈 도금은 산업기계 부품, 자동차 부품, 항공 및 전자 통신 부품 등에 이르기까지 산업 전반에서 폭넓게 사용되고 있다. 이는 무전해 니켈 도금 층이 우수한 균일성, 내마멸성, 내식성 등을 지녀 관련 연구가 지속적으로 활발하게 진행되어 왔기 때문이다. 특히, 최근에 이르기까지 도금 층이 얇고, 우수한 내마멸성 및 낮은 마찰계수를 활용한 무전해 니켈 도금은 산업현장에서 기계 부품들의 수명을 연장시키고, 그 성능을 개선시키는데 용이하게 적용되고 있다. 본 연구에서는 이와 같이 무전해 니켈 도금 층의 우수한 특성을 활용하여 해수 부식과 캐비테이션-침식 복합 환경 하에 놓여 있는 금속 재료의 손상을 방지하고자 하였다. 이는 선박의 경우 최근 고속화, 대형화 추세에 따라 부품의 내구성 향상과 연비 효율성이 더욱 강조되고 있으며, 그에 따라 해수 속에서 고속 회전으로 더욱 가혹해진 캐비테이션 침식-부식 환경하에 놓인 선박의 프로펠러, 펌프 임펠러 및 케이싱 등의 금속재료 자체를 보호할 수 있는 고성능 재료의 개발이 요구되고 있기 때문이다. 또한 해양환경 하에서 무전해 니켈 도금 층에 대한 캐비테이션 침식 손상에 대한 연구는 미비한 실정이다. 본 연구에서는 회주철 표면에 무전해 니켈 도금을 실시하여 캐비테이션 침식 손상을 방지하고자 하였다. 무전해 니켈 도금을 실시하기 전 도금 층을 균일하게 형성하기 위해 샌드 페이퍼 #1200까지 연마 후 알칼리 탈지 실시하고, 산세(10% HCl)와 수세를 순차적으로 실시하여 전처리하였다. 이후 무전해 니켈 도금은 황산니켈, 차아인산나트륨, 구연산, 아세트산나트륨 그리고 미량의 질산납으로 구성된 도금욕에서 pH 4-6, $80-90^{\circ}C$의 조건으로 실시하였으며, pH는 NaOH를 이용하여 조정하였다. 이렇게 제작된 무전해 니켈 도금 층에 대하여 천연 해수 속에서 ASTM-G32 규정에 의거한 캐비테이션 침식실험을 통해 내구성을 평가하였다. 캐비테이션 실험 후에는 무게 감소량, 표면 손상깊이, 침식 손상 경향 등을 종합적으로 분석 비교하였다. 그 결과, 회주철에 대하여 무전해 니켈 도금을 실시할 경우 현저한 캐비테이션-침식 저항성 향상이 관찰되었다.

  • PDF

Effect of Coating Materials for Steel on the Threshold of Corrosive Amount of Airborne Chlorides and the Evaluation of Their Corrosion Speeds (강재마감별 부식개시 임계 비래염분량 및 부식속도 평가)

  • Cho, Gyu-Hwan;Lim, Myung-Hyun;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.143-151
    • /
    • 2015
  • Many studies have investigated the airborne chlorides that can weaken the overall durability of the concrete structures due to the corrosion of steel materials, but most of the studies have aimed to examine weathering by exposing various construction materials to the actual oceanic environment. However, with the exposure test, it was difficult to find the threshold of precise corrosive amount of airborne chlorides due to diverse deteriorating environmental factors such as ultraviolet ray, acid rain, floating material from industrial pollution as well as airborne chlorides. Therefore, in this study, an airborne chloride simulator was set up, in oder to conduct a corrosion accelerating test for steels coated by five different finishing materials. As results, it was found that the corrosion began to be observed at $0.58{\sim}0.73mg/dm^2$ for no-coated steel, at $7.89{\sim}8.46mg/dm^2$for urethane-coated steel, at $57.95{\sim}69.48mg/dm^2$ for red lead-coated steel, and at $80.73{\sim}89.35mg/dm^2$ for stainless-coated steel, respectively. Hence, these specific data can be considered as the threshold ranges of corrosion for each coating material for steel.

A Study on Chloride Threshold Level of Polymer Inhibitive Coating Containing Calcium Hydroxide (수산화칼슘을 혼입한 폴리머 방청 코팅의 부식 임계치 향상에 대한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.713-719
    • /
    • 2008
  • Various types of coatings have been developed for use as reinforcement in concrete and to resist chloride environment. The most commonly used coatings are inhibited and sealed cement slurry coating, cement polymer compositing coating and epoxy coating. Cement slurry offers passive protection, epoxy coating offers barrier protection whereas polymer coating offers both passive protection and barrier protection. Moreover, damage during handling of the steel may result in disbondment of the epoxy coating, which would increase the risk of localized corrosion. In the present study, inhibiting technique was used to increase the calcium hydroxide content at the interface up to 20%. Calcium hydroxide provides a high buffering capacity that resists a local fall in pH and thus maintains the alkaline environment necessary to prevent chloride corrosion. This study examines the use of a calcium hydroxide coating on the steel surface to enhance the pH buffering capacity of steel-concrete interface. Finally, the chloride threshold level (CTL) of polymer inhibitive coating calcium hydroxide is evaluated.

Effect of Additional Elements on Efficiency of Al and Zn Sacrificial Anode for Naval Vessels (함정용 Al 및 Zn 희생양극의 효율에 미치는 첨가원소 영향)

  • Choi, Woo-Suk;Park, Kyung-Chul;Kim, Byeong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.277-283
    • /
    • 2015
  • MS(Mild Steel), HTS(High Tensile Steel), HYS(High Yield Steel), AL(Aluminum Alloy) and Composite Materials are used for vessels. Steel Materials are mostly used for vessels because body of a ship have to perform the basic functions such as watertight, preserving the strength and supporting the equipments. The vessels primarily carry out a mission at ocean, so that body of a ship is necessarily rusted. There are several methods to protect the corrosion of vessels such as painting, SACP(sacrificial anode cathodic protection) and ICCP(impressed current cathodic protection). For the sacrificial anode cathodic protection, Al and Zn alloys are normally used. Heavy metals are added to the Al and Zn Alloys for improving the corrosion properties but they are so harmful to the human and environment. Therefore, the use of these heavy metals is strictly regulated in the world. In this paper, Al and Zn Alloys are made by adding the trace elements(Ma, Ca, Ce and Sn) which is not harmful to the human and environment. SEM, XRD, Potentiodynamic Polarization test and Current Efficiency test are conducted for evaluation of Al and Zn Alloys. As a result of the experiment, Al-3Zn-0.6Sn and Zn-3Sn Alloys are more efficient than other Alloys.

Experimental Study on Chloride Penetration into Concrete under Combined Exposure Conditions of Chlorides and High Concentrated Sulfates (고농도 황산염 이온이 함께 존재하는 경우의 염소이온 침투특성에 관한 실험 연구)

  • Oh, Byung-Hwan;Jung, Sang-Hwa;Jiang, Yi-Rong;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.173-182
    • /
    • 2003
  • Recently, the durability of concrete structures has received great attention as the number of sea-side structures, such as new airport, bridges, and nuclear power plants, increases continuously. In this regards, many studies have been done on the chloride attack in concrete structures. However, those studies were confined mostly to the single deterioration due to chloride only, although actual environment is rather of combined type. The purpose of the present study is, therefore, to explore the effects of combined deterioration due to chlorides and sulfates in concrete structures. To this end, comprehensive experimental program has been set up to observe the chloride penetration behavior for various test series. The test results indicate that the chloride penetration is more pronounced for the case of combined attack than the case of single chloride attack. The surface chloride content is found to increase with time and the diffusion coefficient for chloride is found to decrease with time. The prediction equations for surface chloride content and diffusion coefficient were proposed according to test results. The equations for chloride penetration considering the time-dependent diffusion coefficients and surface chlorides were also suggested. The present study allows more realistic assessment of durability for such concrete structures which are subjected to combined attacks of chlorides and high concentration sulfates but the future studies for combined environment will assure the precise assessment.

Design of Pultruded I-shape FRP Compression Member (펄트루젼 I형 FRP 압축재의 설계)

  • Joo, Hyung-Joong;Lee, Seung-Sik;Yi, Jong-Seok;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.25 no.2
    • /
    • pp.46-53
    • /
    • 2012
  • Using pultrusion process, FRP composite structural members having various cross-section shapes can be produced with unlimited lengths. Because of such reasons, these members are suitable for the application in the construction field. Especially, this material is highly appreciated if the material is to be used in the corrosive environments such as aquatic or oceanic environments due to its high corrosion resistance. However, design criteria for the FRP structural member are not developed yet. So, the research on the development of design guideline is needed ungently. In order to use the pultruded structural FRP member efficiently, the members are composed of thin plate components, and thus, the member is prone to buckle easily and the buckling is one of the governing strength limit states for the design. In this paper, we present the analytical study results pertaining to the buckling behavior of I-shape FRP compression member. In addition, design procedure and flow-chart are also proposed based on the study results including previous experimental results. Proposed design procedure is similar to that in ANSI/AISC 360-10 with minor modification. Therefore, it is convinced that the structural design of pultruded FRP compression member could be done easily by following design procedure proposed in this paper.

A Study on the Frictional Characteristics of Fiber Reinforced Composites under Corrosive Environment (부식 환경 하에서의 섬유강화복합재료의 마찰 및 마모 특성 연구)

  • Choong-Yong Park;Dong-Hyun Park;Soo-Jeong Park;Yun-Hae Kim
    • Composites Research
    • /
    • v.36 no.1
    • /
    • pp.37-41
    • /
    • 2023
  • The treated water inside the ballast electrolytic cell creates a highly alkaline atmosphere due to hydroxide generated at the DSA(Dimension Stable Anode) electrode during electrolysis. In this study, a composite material that can replace the weakness of the PE-coated steel pipe used in the existing ballast pipe was prepared. The test samples are BRE(Basalt fiber reinforced epoxy), BRP(Basalt fiber reinforced unsaturated polyester), GRE(Glass fiber reinforced epoxy), and GRP(Glass fiber reinforced unsaturated polyester). And then it was immersed in NaOH for 720 hours. The friction test of each specimen was conducted. The Friction coefficient analysis according to material friction depth and interfacial adhesion behavior between resin and fiber were analyzed. As a result, the mechanism of interfacial separation between resin and fiber could be analyzed. In the case of the unsaturated polyester resin with low interfacial bonding strength the longer the immersion time in the alkaline solution, the faster the internal deterioration caused by the deterioration that started from the surface, resulting in a decrease in the friction coefficient. It is hoped that this study will help to understand the degradation behavior of composite materials immersed in various chemical solutions such as NaOH, acid, and sodium hypochlorite in the future.