• Title/Summary/Keyword: 복합강우

Search Result 191, Processing Time 0.027 seconds

A 3-D Structural Analysis of Composite Sabot (복합재 이탈피의 3차원 구조해석)

  • 이성호;이강우;박관진;송흥섭
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.65-72
    • /
    • 2003
  • Composite sabot can increase the penetration performance of APFSDS projectile by reduction of the sabot weight. However, it has a thick-sectioned lamination and the lamination structure is different from those of the conventional composite parts. In this study, modeling technique for a thick and radially-laminated composite part has been applied in the finite element analysis of composite sabot. Four models of composite lamination for the sabot have been proposed and evaluated for their structural strength.

Analysis of Classification Characteristics for Rainfall-runoff and TOC Variation according to the Change of Map Size and Array using SOM (SOM 적용을 위한 Map Size와 Array의 변화에 따른 강우-유출 및 TOC관계 분석)

  • Park, Sung-Chun;Kim, Yong-Gu;Roh, Kyong-Bum;Lee, Han-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2066-2070
    • /
    • 2008
  • 본 연구는 인공신경망(Artificial Neural Networks: ANNs)기법의 일종인 자기조직화(Self Organizing Map: SOM) 이론을 이용한다. 자기조직화 특성을 이용하여 스스로 학습이 가능하고, 구조상 수행이 빨라 학습 단계에 소요되는 시간을 줄 일 수 있는 장점을 가진 자기조직화 이론을 도입하고, 수질자료 중 전체 유기물의 양을 나타내며 난분해성 물질에 대한 해석이 가능하고 재현성이 탁월한 TOC 와 강우-유출량 자료의 분포적 양상과 특징을 분석하여 예측을 위한 모형화 과정에 기여하고자 한다. 최적의 Map Size와 Map Array 결정을 위해 수집된 강우와 유출량자료 및 TOC 자료에 대해 Garcia의 경험식을 이용하여 Map을 구성하는 단위구조의 총 수(M)를 산정하여 M값에 따른 종방향 및 횡방향 크기를 결정하는 다수의 Map 크기를 검토하고, 또한 Map 배열은 2차원 배열의 사각형배열(Rectangular array)과 육각형배열(Hexagonal array)에 대해서도 복합적으로 검토하여 최적의 특성조건을 결정하여 강우-유출 및 TOC 관계의 분할특성을 분석한다.

  • PDF

Runoff Analysis on the Major Water-level Station at Nakdong basin (낙동강 유역 주요지점의 유출분석)

  • Kim, Sam-Eun;Kim, Chi-Young;Choi, Kyu-Hyun;Hong, Seong-Hun;Kim, Dong-Chun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.267-272
    • /
    • 2011
  • 수문학적인 물의 순환은 여러 기상인자들과 영향을 주고 받으며 복합적으로 발생하는 자연현상이다. 바로 이 물의 순환과정을 통해 물의 이동은 시간 및 공간적인 변동성을 가진다. 강수량이 많을 때는 하천의 통수능력을 초과함으로써 홍수를 발생시키기도 하며, 반대로 장기간에 강수가 전혀 없어 하천유출이 중단되어 가뭄을 발생시키기도 한다. 이에 따라 본 연구에서는 강우 자료의 확보가 용이하고, 과거로부터의 관측자료의 신뢰성이 높은 기상청 자료와 2007년부터 2010년 동안의 낙동강 본류와 주요지점을 대상으로 강우특성 및 강우량에 의한 첨두홍수량 비교분석, 지점별 강우에 따른 유출률변화 특성을 비교분석을 실시하였다. 대상지점의 자료는 유량조사사업단 실시한 낙동강유역의 실측된 유량자료를 이용하였다. 강우특성에 의한 낙동강 본류 주요지점을 선정하여 첨두홍수량을 비교 하였으며 유출률 비교를 위해 선정된 지점은 연속적인 수위-유량관계곡선식이 개발되어 안정적인 시계열자료를 산출할 수 있는 지점으로 낙동강권역의 유역특성을 대표할 수 있는 낙동강하류에 위치한 진동 지점과 도시하천의 특성을 나타내는 금호강유역에 위치한 동촌 지점 및 남강댐 하류에 위치하여 댐방류량에 의한 하천유지유량이 발생하는 정암 지점을 선정하여 유출률분석을 실시하였다. 세 지점의 유출률은 해당연도의 강우량에 따라 변화 되는 양상을 보였다. 이는 저 평수기 토양 침투 및 증발에 의한 자연적인 손실과 가용하천유량이 적어짐에 따른 취수량의 유출량에 대한 양적 비율의 증가가 원인으로 예상된다.

  • PDF

Characteristics of Non-Point Pollution Discharge of Urban Area According to Land Use (토지이용도에 따른 도시하천의 비점오염원 유출특성)

  • Park, Sung-Chun;Oh, Chang-Ryol;Kim, Jung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1229-1233
    • /
    • 2005
  • 본 연구는 도시지역의 강우-유출로 인한 비점오염물질의 유출특성 및 배출부하량을 조사하기 위하여 영산강권역의 풍영정천을 대상으로 조사하였다. 대상 유역의 토지이용별 구분은 논지역, 하류공단 및 논$\cdot$산지 복합 토지 이용특성, 공단 지역, 도시 분류식 지역, 소유역 출구지역으로 구분하였다. 시료의 채취는 강우시 4회에 걸쳐 조사하였으며, 매회 시료 채취 주기는 강우유출이 발생하기 전부터 시작하여 첨두유출량이 발생때까지 $1\~2$시간 간격으로 채취한 후 강우 종료 후 유출량 변화가 없을 때까지 $9\~12$단계로 세분하여 유출량과 pH, DO, BOD, COD, SS, T-N, T-P의 농도를 측정 하였다. 토지이용별 비점오염물질의 유량가중평균농도(EMC : Event Mean Concentration)를 살펴보면, BOD의 EMC는 $4.43\~14.22mg/{\ell}$의 분포를 보였으며, 도시 합류식 토지이용 특성을 지닌 P-4지점에서 가장 큰 농도를 보였을 뿐만 아니라 타 토지이용 특성에 비하여 두드러지게 초기 오염물질 유출 현상을 나타내었다. COD의 EMC는 $8.27\~18.81mg/{\ell}$의 분포를 보였으며, BOD 수질농도와 같이 P-4 지점에서 가장 큰 농도를 갖는 것으로 나타났다. SS의 EMC는 $35.76\~358.86mg/{\ell}$의 분포를 보였으며, 소유역의 중간지점이면서 논$\cdot$산지$\cdot$공단지역의 토지이용 특성을 지닌 P-2 지점에서 가장 큰 농도를 나타내었다. 이는 조사기간(Event 1, Event2) 동안 상류의 자연형하천 제방공사로 인한 토사유출로 인하여 다소 높게 나타난 것으로 판단된다. 또한, 대상유역 전반적으로 초기 오염물질 유출 현상을 보였으며, BOD와 COD 수질농도의 분포양상과는 다르게 강우량 및 강우강도에 많은 영향을 받는 것으로 나타났다. T-N의 EMC는 $1.61\~7.13mg/{\ell}$의 분포를 보였으며, T-P는 $0.03\~0.46mg/{\ell}$의 분포를 갖는 것으로 나타났다.

  • PDF

Characteristics of Non-Point Pollution Discharge According to Land Use in Yeinam Watershed (외남천 유역의 토지이용도에 따른 비점오염원 유출특성)

  • Park Sung Chun;Kim Yong Gu;Rho Mun Soo;Lee Han Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1234-1238
    • /
    • 2005
  • 우리나라의 수질오염에 대한 규제는 주로 호소 및 하천의 수질을 향상시키기 위하여 하수 및 공장폐수 등 점오염원을 중심으로 관리되어 왔으나 강우와 함께 대량 유출된 비점오염원은 수용하천의 자정능력을 감소시키고 있고 이로 인해 하천과 호소의 수질은 향상되지 못하고 있다. 또한, 농촌지역에서 배출되는 비점오염원은 정확한 기작의 분석이 안 되고 있으며, 비료$\cdot$농약의 사용 증가에 따라 영양염 및 유해물질에 의한 수질오염의 영향이 증가되고 있는 실정이다. 본 연구는 농촌지역의 강우-유출로 인한 비점오염물질의 유출특성 및 배출부하량을 조사하기 위하여 영산강권역의 외남천을 대상으로 조사하였다. 대상 유역의 토지용도 구분은 (1)논지역, (2)밭지역, (3)산지지역, (4)농촌주거지역, (5)복합지역(논, 산지)으로 구분하였다. 시료의 채취는 강우시 5회에 걸쳐 조사하였으며, 2L 용량의 무균채수병에 채취한 후, 아이스박스에 $4^{\circ}C$이하로 보관하여 24시간 이내로 실험실에 운반하여 실험하였으며, 매회 시료 채취 주기는 강우유출이 발생하기 전부터 강우 종료 후 유출량 변화가 없을 때까지 $9\~12$단계로 세분하여 유출량과 pH, DO, BOD, COD, SS, T-N, T-P의 농도를 측정하였다. 본 연구에서 조사한 결과 토지이용별 비점오염원의 SMC를 살펴보면 BOD의 SMC는 $4.38\~11.02mg/{\ell}$, COD의 SMC는 $7.07\~23.99mg/{\ell}$, T-N은 $1.57\~5.20mg/{\ell}$, T-P는 $0.11\~0.274mg/{\ell}$의 범위를 갖는 것으로 나타났으며, 전반적으로 논 지역에서 비교적 높게 나타났는데 이는 농작물의 경작에 따른 시비법의 영향으로 판단된다. 또한, 비점오염원의 유출특성을 보면 전반적으로 초기 오염물질 유출특성 갖는 것으로 나타났다.

  • PDF

Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces (수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가)

  • Kim, Bong Kyun;Seo, Dae Seuk;Oh, Jong Min;Park, Jae-Ro
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.238-246
    • /
    • 2016
  • Water purification facilities utilizing three technologies - a detention pond, an artificial wetland and an ecological revetment - were installed in waterfront spaces, including river embankments and watersides that have so far been left neglected, and then their water purification levels were analyzed in this study. The water purification facilities were found to show average removal efficiencies of 48.6% in suspended solid (SS), 30.5% in biochemical oxygen demand (BOD), 18.4% in total nitrogen (T-N) and 27.3% in total phosphorus (T-P) during rainfall. The removal efficiencies during non-rainfall were 33.2% in SS, 28.6% in BOD, 13.7% in T-N and 17.3% in T-P. These results showed that the water purification facilities using a detention pond, an artificial wetland and an ecological revetment can be used as a useful natural water purification technology in in waterfront spaces.

A Development of Method for Surface and Subsurface Runoff Analysis in Urban Composite Watershed (II) - Analysis and Application - (대도시 복합유역의 지표 및 지표하 유출해석기법 개발 (II) - 분석 및 적용 -)

  • Kwak, Chang-Jae;Lee, Jae-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.53-64
    • /
    • 2012
  • In this study (II), the module developed in the previous study (I) has been tested on application and numerical stability. The runoff module was compared the result of analysis with two different models (FFC2Q and $Vflo^{TM}$) considering characteristic of infiltration. To examine the application and stability of developed module, runoff aspect was simulated under the variety case of rainfall intensity, effective soil depth, elapsed time. The development module was presented typical type of infiltration process looking physically, the different of saturation point on soil type, and characteristic of soil type. Also, the module was reflected in the runoff feature about rainfall intensity and time distribution. Finally, this paper drew a conclusion that result of rainfall-runoff analysis as compared with difference models (FFC2Q and $Vflo^{TM}$) has a high accuracy.

Development of Flood Management System using Complex Event Processing(CEP) Technique (복합 이벤트 처리기법을 이용한 수해관리시스템 개발)

  • Kim, Hyung-Woo;Chang, Sung-Bong
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.51.1-51.1
    • /
    • 2010
  • 본 논문은 중소 도시하천을 위한 수해관리시스템 개발에 관한 것이다. 일반적으로 도시하천은 집중호우 발생 시 수위가 급격히 상승하는 특성이 있으므로 하천 재난관리 측면에 있어서 특별한 주의가 필요하다. 따라서 이와 같은 하천의 경우에는 강우와 유출 관계식으로부터 수립된 수문학적 모형을 사용하여 홍수 발생 여부를 예측하는 것 보다는 하천 수위의 실시간 변동 상황을 즉시 감지하고 위험상황 발생 시 이를 신속히 전파하는 것이 재난관리 측면에 있어 더욱 유리할 수 있다. 본 연구에서는 이를 위하여 실시간 센서 데이터를 보다 효율적으로 처리할 수 있는 복합 이벤트 처리기법을 사용하여 수해관리시스템을 개발하였다. 또한, 외부의 재난관리시스템과 정보를 공유하며 연동을 원활히 수행할 수 있으며 경보를 다수의 사용자에게 효과적으로 전파할 수 있는 이벤트 주도적 아키텍처를 적용하였다. 본 연구를 통해서 최근 실시간 데이터 처리기법으로 주목을 받고 있는 복합 이벤트 처리기법이 수해관리에 효과적임을 알 수 있었으며 타 분야의 재난관리에도 널리 적용될 수 있는 것으로 파악되었다.

  • PDF

Analysis of inundation map considering sea level in coastal city and detailed flood vulnerability assessment (해수위를 고려한 연안지역 홍수피해 침수예상도 작성 및 상세홍수취약성 분석)

  • Choi, So Hyun;Kim, Young Jun;Jun, Hwan Don
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.288-288
    • /
    • 2019
  • 지구온난화로 인해 해수면이 지속적으로 상승하고 있으며, 이에 따라 연안인근 지역은 복합원인에 의한 홍수피해가 빈번히 발생하고 있다. 우리나라는 반도 지형으로 해수면 상승에 따라 침수피해 발생 시 피해규모가 클 것으로 예상되어 이에 적극적으로 대처할 필요가 있다. 복합원인에 의한 침수예상도는 해수위를 고려한 내외수 침수피해 발생 시 침수의 범위 및 양상을 예측한다. 먼저 침수발생 시 피해규모가 클 것으로 예상되는 연안인근의 도심지역을 위주로 대상지역을 선정하였으며, 침수발생 원인별 침수예상도를 작성하였다. 작성된 침수예상도를 바탕으로 상세 홍수취약성을 평가하였으며, 이를 바탕으로 주요 시설물의 위치 선정, 관거 개량의 우선순위 선정 등에 활용할 수 있다. 먼저 도상조사를 통해 침수발생 후보지역을 선정하고, 현장답사를 통해 현장 변경사항, 재해원인 및 재해발생가능성을 검토하여 대상지역으로 여수시 연등천 인근을 선정하였다. 모의 방법으로는 HEC-HMS 및 XP-SWMM 등 강우-유출 모형에 의해 침수해석을 실시하고, 하류단 경계조건의 변화에 따른 기점수위를 산정하여 해수위를 고려하였다. 하류단 경계조건으로는 대상지역의 폭풍해일에 의한 해수위 상승고를 적용하였다. 배수토구가 하천으로 연결된 경우에는 해당 하천의 홍수위 산정이 필요하며 홍수위 산정에는 HEC-RAS 모형을 사용하였다. 작성된 침수예상도를 통해 상세 홍수취약성 분석을 실시하였으며, 상세 홍수취약성 지수는 "기후변화 적응을 위한 연안도시지역별 복합원인의 홍수 취약성 평가기술 개발 및 대응방안 연구"에서 개발된 지표를 기반으로 산정하였다. 본 연구에서는 강우-유출 모형의 하류단 경계조건 변화를 통해 해수위 상승을 고려하여 연안도시 지역의 침수예상도를 작성하였으며, 침수발생 예상도를 통해 상세 홍수취약성을 분석하였다. 이는 침수발생에 따른 대피지도 개발, 주요 시설물의 계획, 침수피해 예방을 위한 구조적 대책 수립을 위한 기초자료로 활용될 수 있다.

  • PDF

Application of Detention and Infiltration-based Retention Hybrid Design Technique to Oncheon Stream (유수지 및 침투기반 저류지 복합설계기법의 온천천 유역 적용)

  • Choi, Chi Hyun;Kim, Eungseock;Kim, Jin Kwan;Kim, Sangdan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2B
    • /
    • pp.99-108
    • /
    • 2011
  • In this study a hybrid design scheme for the purpose of designing infiltration-based retentions and a detention is applied to reproduce urban hydrologic regime to natural hydrologic regime. The proposed method is based on the NRCS-CN stormwater estimation technique, and applied to determine the size for stormwater control facilities on the Oncheon stream as an example. Urban area, corresponding to less than 70 m height of the Oncheon stream basin area is targeted. The results indicate that the proposed scheme is very useful to reproduce its undeveloped flow-duration curve.