• 제목/요약/키워드: 복층창

검색결과 4건 처리시간 0.016초

비정질 박막 투과형 태양전지모듈의 온도특성에 따른 발전성능 평가 연구 (A Study on the Evaluation of Power Performance according to Temperature Characteristics of Amorphous Transparent Thin-Film)

  • 안영섭;송종화;이성진;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2009
  • This study evaluated the influence of temperature on the PV module surface on power output characteristics, especially for an amorphous transparent thin-film PV module which was applied to a full-scale mock-up model as building integrated photovoltaic system. The tested mock-up consisted of various slopes of PV module, facing to the south. The annual average temperature of the module installed with the slope of $30^{\circ}$ revealed $43.1^{\circ}C$, resulting in $7^{\circ}C$ higher than that measured in PV modules with the slope of $0^{\circ}$and $90^{\circ}$ did. This $30^{\circ}$ inclined PV module also showed the highest power output of 28.5W (measured at 2 PM) than other two modules having the power output of 20.4W and 14.9W in the same time for $0^{\circ}$ and $90^{\circ}$ in the slope, respectively. In case of the $30^{\circ}$ inclined PV module, it exhibited very uniform distribution of power output generation even under the higher temperature on the module surface. Consequently, the surface temperature of the PV module analyzed in this study resulted in 0.22% reduction in power output in every $1^{\circ}C$ increase of the module surface temperature.

  • PDF

건물 외피에 적용된 복층창의 열팽창 파손에 대한 민감도 분석 연구 (The Sensitivity Analysis of Thermal Expansion Breakage of Multi-layer Glazing in Building Envelope)

  • 윤종호;김승철;임경업;오명환
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.93-97
    • /
    • 2014
  • Curtain wall system of office buildings has recently become very common in Korea. As the multi-layer curtain glazing is exposed to outdoor environment, it is very subjected to direct environmental impact. Consequently, breakage and cracks of glazing due to heat expansion is frequently observed. This study explores various causes and aspects for destruction of multi-layer glazing. A sensitivity analysis was performed on the basis that thermal changes causes damage to the multi-layer glazing. Air temperature in air cavity within the multi-layer glazing was examined to find its effect on multi-layer glazing breakage. Analysis showed high deflection to depth ratio of 1:1.8 and that higher the aspect ratio, smaller is the deflection. Allowable pressure showed that the weakest value is for aspect ratio of 1:2.9. Sensitivity analysis by the area of the glazing showed that as area of glazing becomes higher, allowable pressure and deflection-depth ratio becomes smaller. For allowable pressure and allowable deflection-depth within air cavity, the glazing breakage occurred at least $107^{\circ}C$. The results from glazing breakage by thermal factor shows that it is hard to break the glazing with only an increase in air cavity temperature in multi-layer glazing applied in buildings.

2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구 (A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility)

  • 강정훈;곽용건;노승욱;박대호;이주호;홍완표;황인규;박동소
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구 (A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer)

  • 박동소
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5284-5289
    • /
    • 2011
  • 본 연구에서는 대학 캠퍼스의 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열관류율(U-value) 평가를 수행하였다. 교육시설의 주요 창호 재료로 적용된 알루미늄은 열전도율이 175 $kca{\ell}/m^2h^{\circ}C$ 정도로 플라스틱 소재의 창틀과 비교할 때, 매우 불리하여 기존 교육시설에 설치된 알루미늄 창호는 열교를 통한 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 알로이 합금 창호의 열관류율 평가에 관한 연구를 수행하여 다음의 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물 에너지절약설계기준의 남부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 시물레이션을 통한 해석 결과 열관류율은 알루미늄 합금 창호 U= 9.631 W/$m^2K$, 복층유리 U= 2.382 W/$m^2K$로 여름철과 겨울철 동일한 해석 결과치가 산출되었다. (2) 열관류율 해석결과를 "건축물의 에너지절약설계기준"의 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반 복층창 단열성능기준인 U=4.0 W/$m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열손실이 발생됨을 보여 주고 있다.