• Title/Summary/Keyword: 복사효과

Search Result 372, Processing Time 0.031 seconds

Numerical Study on the Thermal NOx Reduction by Addition of Moisture in LNG Flame (가습 공기의 LNG 화염 Thermal NOx 저감의 수치 해석적 연구)

  • Shin, Mi-Soo;Park, Mi-Sun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.837-842
    • /
    • 2014
  • A computer program is developed for the prediction of NO generation by the addition of water moisture and water electrolysis gas in LNG-fired turbulent reacting flow. This study is the first part to deal with the moisture effect on NO generation. In this study, parametric investigation has been made in order to see the reduction of thermal NO as a function of amount of moisture content in a LNG-fired flame together with the swirl and radiation effect. First of all, calculation results show that the flame separation together with the NO concentration separation are observed by the typical flow separation due to strong swirl flow. With a fixed amount of air, the increased amount of water moisture from 0 to 10% by 2% interval shows the decrease of NO concentration and flame temperature at exit are from $973^{\circ}C$ and 139 ppm to $852^{\circ}C$ and 71 ppm. The radiation effects on the generation on NO appears more dominant than swirl strength over the range employed in this study. However, for the strong swirl flow employed in this study, the flow separation cause the relatively high NO concentration observed near exit after peak concentration in the front side of the combustor.

The Effects of Trunk Stabilization Exercise on the Isometric Muscle Power and Muscle Activation in Chronic Low Back Pain (체간 안정화운동이 만성 요통환자의 근력과 근활성도에 미치는 영향)

  • Kim, Hyoung-Su;Hyong, In-Hyouk;Kim, Eun-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to know influenced on the change of Oswestry back pain disability index(OBPDI), isometric muscle power(IMP), muscular activation with chronic low back pain(CLBP) patients after Trunk Stabilization Exercise. Intervention was provided 6 weeks(5 days a week). Muscular activation was measured during IMP(Muscles : transversus abdominis : TA, internal obliqus : IO, external obliqus : EO, rectus abdominis : RA and erector spinae: ES). The results were as follows. 1. OBPDI about the MBE and the SE groups had effective decrease pain and disability. 2. IMP of intervention after the MBE and the SE groups had effective improve muscle power. 3. Muscle activation during IMP of intervention after was : TA, IO, RA had increase in the MBE and the SE groups. EO muscle activation during IMP of intervention after had increase only MBE groups. This shows that the MBE and the SE groups had effective increase because it has effective improve muscle power. Therefore, this study shows £hat trunk stabilization exercise program influenced on the change of OBPDI, IMP, muscular activation with CLBP patients.

Effectiveness of the Aluminum Thermal Screens Depending on the Allocation Type (알루미늄반사재의 배치형태에 따른 보온 효과)

  • Kim, Young-Bok;Park, Joong-Choon;Huh, Moo-Ryong;Lee, Si-Young;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.284-290
    • /
    • 2007
  • Thermal insulation effectiveness of the aluminum insulator depending on the direction of its glossing face, number of layer and allocation position was investigated. Modules were assembled by the combination of the variables levels and experimented for the case of 100 W and 40 W heating in the modules. The temperatures in the modules with the aluminum insulator were higher than those of the modules with polyester curtains. For the modules with one layer aluminum insulator, the inside temperatures of the modules with the direction of the glossing face outward were higher than those of the modules of inward. For two layer of aluminum insulator, the directions of those glossing faces were recommended to be the same direction for higher thermal insulation effectiveness. For the modules without heating, the temperature difference between the modules were not significant. The black globe temperatures in the modules were changed with the similar tendencies with the dry bulb temperatures in the modules. Those of the black globes were higher than those of the dry bulb temperatures as a whole. It was more distinguished for the modules of inward direction.

A Study on the Shielding of Iodine 131 Using Monte Carlo Simulation (몬테칼로 모사를 이용한 방사성옥소 I-131의 차폐체에 대한 효용성 연구)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Kim, Jung-Ki;Lee, Sang-Ho;Choi, Hyung-Seok;Bae, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.143-150
    • /
    • 2014
  • This study was designated to investigate the bremsstrahlung and radiation dose by beta rays. Radiation attenuation from I-131 treatment ward was analyzed using radio protective apron. Shielding materials which is included lead or water were simulated in Monte Carlo Simulation then the spectrum on interaction was analyzed. The shielding materials were categorized according to the thickness. 0.25mm and 0.5mm thick lead and 0.1mm and 0.2mm thick water shielding materials were configured in Monte Carlo Simulation for this study. Only lead shielding method and water plus lead shielding method were carried. As a results, when 0.5mm thick lead shielding method was performed, the radiation dose was similar to the results with water plus lead shielding method. In case of using 0.25mm thick lead shielding, the shielding effect was somewhat less. However, that shielding method cause dose reduction of about 60% compare with non-shielding material.

Effect of Coolants and Metal Bumps on the heat Removal of Liquid Cooled Microchannel System (액랭식 마이크로채널 시스템 내 냉매와 범프의 열 제거 효과에 대한 연구)

  • Won, Yonghyun;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.61-67
    • /
    • 2017
  • As transistor density increases rapidly, a heat flux from IC device rises at fast rate. Thermal issues raised by high heat flux cause IC's performance and reliability problems. To solve these thermal management problems, the conventional cooling methods of IC devices were reached their thermal limit. As a result, alternative cooling methods such as liquid heat pipe, thermoelectric cooler, thermal Si via and etc. are currently emerging. In this paper microchannel liquid cooling system with TSV was investigated. The effects of 2 coolants (DI water and ethylene glycol 70 wt%) and 3 metal bumps (Ag, Cu, Cr/Au/Cu) on cooling performance were studied, and the total heat flux of various coolant and bump cases were compared. Surface temperature of liquid cooling system was measured by infrared microscopy, and liquid flowing through microchannel was observed by fluorescence microscope. In the case of ethylene glycol 70 wt% at $200^{\circ}C$ heating temperature, the total heat flux was $2.42W/cm^2$ and most of total heat flux was from liquid cooling effect.

A Study on the Radiometric Correction of Sentinel-1 HV Data for Arctic Sea Ice Detection (북극해 해빙 탐지를 위한 Sentinel-1 HV자료의 방사보정 연구)

  • Kim, Yunjee;Kim, Duk-jin;Kwon, Ui-Jin;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_2
    • /
    • pp.1273-1282
    • /
    • 2018
  • Recently, active research on the Arctic Ocean has been conducted due to the influence of global warming and new Arctic ship route. Although previous studies already calculated quantitative extent of sea ice using passive microwave radiometers, melting at the edge of sea ice and surface roughness were hardly considered due to low spatial resolution. Since Sentienl-1A/B data in Extended Wide (EW) mode are being distributed as free of charge and bulk data for Arctic sea can be generated during a short period, the entire Arctic sea ice data can be covered in high spatial resolution by mosaicking bulk data. However, Sentinel-1A/B data in EW mode, especially in HV polarization, needs significant radiometric correction for further classification. Thus, in this study, we developed algorithms that can correct thermal noise and scalloping effects, and confirmed that Arctic sea ice and open-water were well classified using the corrected dual-polarization SAR data.

Scenario-Based Analysis on the Effects of Green Areas on the Improvement of Urban Thermal Environment (녹지 조성 시나리오에 따른 도시 열환경 개선 효과 분석)

  • Min, Jin-Kyu;Eum, Jeong-Hee;Sung, Uk-Je;Son, Jeong-Min;Kim, Ju-Eun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.6
    • /
    • pp.1-14
    • /
    • 2022
  • To alleviate the urban heat island phenomenon, this study aims to quantitatively analyze the effects of neighborhood green spaces on the improvement of the thermal environment based on detailed scenarios of five types of green spaces, including parks, pocket parks, parking lot greening, roadside planting, and rooftop-wall greening. The ENVI-met 4.4.6v model, a microclimate simulation program, was used to analyze the effects of green spaces. As a result, it was found that the air temperature decreased as the planting density of the park increased, but the thermal comfort index PET, which is the degree of heat sensation felt by humans, was not directly proportional to temperature. The establishment of a pocket park reduced air temperature up to a radius of 56m, while the range of temperature reduction increased by about 12.5% when three additional pocket parks were established at 250m intervals. Unlike the air temperature, PET was only affected in the vicinity of the planted area, so there was no significant difference in the thermal comfort of the surrounding environment due to the construction of pocket parks. Changing the surface pavement from asphalt to lawn blocks and implementing rooftop or wall greening did not directly act as solar shading but positively affected air temperature reduction; PET showed no significant difference. Roadside planting showed a higher air temperature reduction effect as the planting interval was narrower, but PET was not directly proportional to tree density. In the case of shrub planting under trees, it did not significantly affect the air temperature reduction but positively affected the improvement of thermal comfort. This study can outline strategies for constructing neighborhood green spaces to solve the urban heat island phenomena and establish detailed strategies for efficient thermal environment improvements.

The Quantitative Analysis of Cooling Effect by Urban Forests in Summer (여름철 도시 인근 산림에 의한 냉각효과의 정량화에 대한 연구)

  • Lee, Hojin;Cho, Seongsik;Kang, Minseok;Kim, Joon;Lee, Hoontaek;Lee, Minsu;Jeon, Jihyeon;Yi, Chaeyeon;Janicke, Britta;Cho, Changbeom;Kim, Kyu Rang;Kim, Baekjo;Kim, Hyunseok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.73-87
    • /
    • 2018
  • A variety of micro meteorological variables such as air temperature, wind, solar radiation and latent heat at Gwangneung forests (conifer and broadleaved forests) and AWS (Automated Weather Station) of Pocheon urban area were used to quantify the air temperature reduction effect of forests, which is considered to be an eco-friendly solution for reducing the urban heat island intensity during summer. In June, July and August of 2016 and 2017, the average maximum air temperature differences between above and below canopy of forests, and between the forests and urban areas were $-1.9^{\circ}C$ and $-3.4^{\circ}C$ respectively, and they occurred at 17:00. However, there was no difference between conifer and broadleaved forests. The effect of air temperature reduction by the forests was positively correlated with accumulated evapotranspiration and solar radiation from 14:00 to 17:00 and showed a negative correlation with wind speed. We have developed a model to quantify the effect of air temperature reduction by forests using these variables. The nighttime air temperature reduction effect by forests was due to the generation of cold air from radiative cooling and the air temperature inversion phenomenon that occurs when the generated cold air moves down the side of mountain. The model was evaluated in Seoul by using 28 AWSs. The evaluation shows that the air temperature of each district in Seoul was negatively correlated with the area and size of the surrounding tall vegetation that drives vegetation evapotranspiration during the day. During the night, however, the size of the surrounding tall vegetation and the elevations of nearby mountains were the main influencing factors on the air temperature. Our research emphasizes the importance of the establishment and management of urban forests and the composition of wind roads from mountains for urban air temperature reduction.

Studies on Soil Conservation Effects of the Straw-mat Mulchings (I) - Vegetation Establishment and Erosion Control Effects - (볏짚거적덮기공의 사방효과(砂防効果)에 관(關)한 연구(硏究)(I) - 사면지피조성(斜面地被造成) 및 침식방지(浸蝕防止) 효과(効果) -)

  • Woo, Bo Myong
    • Journal of Korean Society of Forest Science
    • /
    • v.13 no.1
    • /
    • pp.67-78
    • /
    • 1971
  • The measures of contour-terracing with sod has been executed as a major measures for hillside erosion control works for a long time in Korea. It is, however, recognized that pair terracings make a new slope-face having the more steeper degree of slope between the upper and the lower terraces on hillsides and it also does not contribute for establishing the natural vegetation-cover by penetration of pioneer seeds on the slope faces or cut-faces of hillsides. The study was therefore conducted in connection with the above problems on the cut-face having slope of $40^{\circ}$ and 1.6 meter in slope length with clay soils. Plot allocation for the experiment consists of 3 kinds of 3 replica plots having each $1.6m^2$ of slope area, i. e., the control plot with direct seeding on slopes only ($T_1$), the covering plot with the straw-mats after seeding on slopes ($T_2$) and the seeding plot after covering with the straw-mats. ($T_3$). The main results obtained may be summarized as follows : 1. Effects of the straw-mat mulchings on surface soil loss control:-The total amount of soil losses from each treatments are measured as 4,651 gr from $T_1$, 163 gr. from $T_2$ and 2,891 gr. from $T_3$ treatment respectively. (Refer to table No. 2, 3 and 4). In short, it is recognized that effect of $T_2$ treatment is compared as 28.5 times than that of $T_1$ treatment and 17.7 times than that of $T_3$ treatment respectively. Effect of $T_3$ treatment compared with $T_1$ treatment is also such recognizable as 1.6 times in control of surface soil losses on a slope face. 2. Effect of the straw-mat mulchings on soil moisture content on slopes; -Average per cent of surface soil moisture content by treatments show as 21.60 at the $T_1$, 23.04 at the $T_2$ and 22.21 at the $T_3$ treatment respectively and that of subsurface soil moisture content by treatment show as 23.81 at the $T_1$, 26.16 at the $T_2$ and 24.81 at the $T_3$ treatment respectively. The variance of soil moisture content by treatments was highly significant (Refer table No. 7, 8 and 9). 3. Effect of the straw-mat mulchings on vegetation establishment;-Average numbers of germination by treatments are counted as 237 Nos. at the $T_1$, 246 Nos. at the $T_2$ and 262 Nos. at the $T_3$ treatment plots and the vegetation coverage on ground was almost same as about 90% of covers in all treatments. This effect is more or less lower than that of surface soil erosion control. 4. Regarding the effect on surface soil erosion control, the straw-mat mulchings would be effective as a new measures for control of soil erosion on erosion susceptible lands such slope-faced bare-lands as cut-fill faces, mass-movement faces and bare hillsides.

  • PDF

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.