• Title/Summary/Keyword: 복부촬영

Search Result 352, Processing Time 0.028 seconds

Spontaneous Perinephric Urinoma after the Removal of a Foley Catheter in a Girl with Acute Kidney Injury (급성 신부전 환아에서 유치 도뇨관 제거 후 발생한 신 주위 요낭종 1례)

  • Yang, Tae Hwan;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.127-131
    • /
    • 2013
  • Urinomas can occur after renal trauma or perforation of the collecting system during an endosurgical procedure. However, spontaneous urinomas are very rare. Here we report a case of a spontaneous perinephric urinoma following the removal of a Foley catheter in an 18-year-old girl with acute kidney injury caused by septic shock. The patient had been treated for septic shock, acute kidney injury, and acute respiratory distress syndrome, and had a Foley catheter in place for seven days. After Foley catheter removal, the patient complained of consistent voiding difficulty. An abdominal computed tomography scan showed a large amount of left perinephric fluid, and the aspirated fluid included urothelial cells, confirming the diagnosis of a urinoma. The urinoma was successfully treated by insertion of a double-J stent into the left ureter. This report discusses the available literature on urinomas, and their clinical features, diagnosis, and treatment.

Campylobacter Enteritis: Clinical Features and Laboratory Findings in Children Treated at a Single Hospital

  • Jang, Won Tae;Jo, Na Hyun;Song, Mi Ok;Eun, Byung Wook;Ahn, Young Min
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.1
    • /
    • pp.22-31
    • /
    • 2019
  • Purpose: Campylobacter species are common causes of bacterial enteritis. There is limited knowledge on its prevalence and clinical features because of its fastidious culture conditions. The purpose of this study was to identify the clinical features of Campylobacter enteritis in children. Methods: We obtained stool specimens from patients diagnosed with acute gastroenteritis in the Department of Pediatrics, Nowon Eulji Medical Center (NEMC) and identified the pathogens by performing cultures or polymerase chain reactions (PCR). We retrospectively reviewed the medical records of patients with Campylobacter enteritis at NEMC between January 2012 and December 2017. Results: Overall, 123 patients were diagnosed with Campylobacter enteritis (60 by culture and PCR in EnterNet and 110 by multiplex PCR). The median (interquartile range [IQR]) age of patients was 12 years (IQR, 8 to 16 years). The disease occurred all year round, but 69.9% from June to September. Symptoms included diarrhea (97.6%), fever (96.7%), abdominal pain (94.3%), vomiting (37.4%), and headache (34.1%). Compared with other treatments, treatment with azithromycin was associated with a shorter hospitalization period (P<0.05). Conclusions: Campylobacter enteritis is common during summer and mostly infects adolescent patients. It causes severe abdominal pain and fever preceding the onset of diarrhea. Prompt diagnosis and appropriate use of antibiotics reduces the duration of the disease.

Toxic Megacolon as a Complication of Infectious Colitis Caused by Salmonella enteritidis Group D in a Previously Healthy Child (건강한 소아에서 살모넬라 장염의 합병증으로 발생한 독성거대결장)

  • Jeon, Sung Bae;So, Cheol Hwan;Jo, Young Min;Yu, Seung Taek
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.110-117
    • /
    • 2021
  • Toxic megacolon is a fatal complication of inflammatory or infectious bowel disease. Prognosis depends on the severity of the disease. In cases of poor prognosis, clinical outcomes range from intestinal resection to death, so early diagnosis and appropriate treatment are very important. However, the prevalence of toxic megacolon in children is very low, and in those without underlying diseases such as inflammatory bowel disease, early diagnosis may be delayed. A previously healthy 12-year-old boy presented to our hospital with lower abdomen pain, fever, and hematochezia. Despite antibiotic therapy, the symptoms worsened. On the third day, abdominal computed tomography revealed severe dilatation of the transverse colon, which indicated toxic megacolon. Stool culture was positive for Salmonella enteritidis group D, and rectal endoscopy showed no signs of inflammatory bowel disease. Ceftriaxone and intravenous methylprednisolone were administered, and the patient's condition improved without any complications. We report a case of toxic megacolon as a complication of infectious colitis caused by S. enteritidis group D, which was diagnosed using early imaging and successfully treated without surgical intervention.

Acute Appendicitis: A Rare But Probable Manifestation of Kawasaki Disease

  • Wonshik Choi;Sin Weon Yun;Mineui Hong;Suk-Won Suh;Dae Yong Yi;Ji Young Park
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.97-103
    • /
    • 2023
  • Kawasaki disease (KD) is an acute, systemic inflammatory disorder that often targets coronary arteries. Being the common cause of acquired heart disease in children, timely diagnosis and intravenous immunoglobulin treatment are crucial. However, it is challenging for physicians to diagnose KD if it presents with atypical manifestations. We report the case of a 5-year-old boy who initially presented with appendicitis; after an appendectomy, he had a prolonged fever. He was finally diagnosed with atypical KD and successfully recovered after intravenous immunoglobulin treatment. Through a literature review, we found 21 cases of appendicitis associated with KD. In most cases, the patients were male with a mean age of 5.3 years. Most had higher proportions of incomplete KD and coronary artery complications than expected for typical KD. In conclusion, appendicitis could be a rare complication of KD; therefore, multidisciplinary cooperation and early recognition of atypical KD are essential for timely diagnosis.

Human Immunodeficiency Virus-Associated Gastrointestinal Kaposi's Sarcoma: A Case Report (후천성 면역 결핍 바이러스와 연관된 위장관 카포시 육종: 증례 보고)

  • Hee Joong Lim;So Hyun Park;Seung Joon Choi;Suyoung Park;Hee Young Lee;Jun Won Chung;Dong Hae Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1260-1265
    • /
    • 2020
  • Kaposi's sarcoma (KS) is a multicentric human immunodeficiency virus-associated neoplasm characterized by multiple vascular nodules in the skin, mucous membranes, and viscera. Gastrointestinal acquired immunodeficiency syndrome (AIDS)-related KS is the most common visceral involvement reported in disseminated disease. Here, we present the findings of a rare case of KS involving multiple organs with abdominal pain and active bleeding in the colon. Multiple intraluminal lesions were found in the terminal ileum, sigmoid colon, and rectum by ileocolonoscopy, and in the jejunum and ileum by fluoroscopy. Abdominopelvic CT revealed multiple enhanced flat lesions in the ileum and enlarged lymph nodes. The diagnosis was confirmed by histopathology, and antiretroviral therapy was initiated as the treatment of choice for KS. Owing to the increasing number of AIDS patients, it is essential for radiologists and clinicians to be aware of the imaging characteristics of KS to protect physicians from indiscriminate exposure to AIDS.

Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

A Clinical Manifestation of Meckel's Diverticulum (Meckel 게실의 임상양상)

  • Lee, Jin Beom;Lee, Yong Soon;Yoo, Eun Sun;Kim, Hae Soon;Son, Se Jeong;Park, Eun Ae;Lee, Seung Joo;Sung, Sun Hee;Seo, Jeong Wan
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.466-472
    • /
    • 2002
  • Purpose : The diagnosis of Meckel's diverticulum is difficult and delayed because it presents with various clinical symptoms. We evaluated clinical, imaging and pathologic findings of Meckel's diverticulum to facilitate detection of Meckel's diverticulum in children. Methods : Review of clinical, imaging, surgical and pathological findings in 10 children aged 7 days to 14 years with Meckel's diverticulum during an 8-year period, 1993-2001, at Ewha Womans University Hospital was undertaken. Results : The male to female ratio was 2.3 : 1. The chief complaint was painless lower gastrointestinal( GI) bleeding; others were abdominal pain, abdominal distention and vomiting, in order of frequency. The diagonsis before surgery were Meckel's diverticulum in 5 patients, non-reducible intussusception in 3 patients and intestinal obstruction in 2 patients. The diverticulum was located between 35 cm to 70 cm proximal to the ileocecal valve. The length of the diverticulum ranged from 4 cm to 12 cm and 80% of it was within 5 cm. A Meckel scan($^{99m}Tc-pertechnetate$ scintigraphy) after cimetidine administration was done in 6 cases. All 5 cases that presented with lower GI bleeding had ectopic gastric mucosa confirmed on pathology. Out of 5 cases of ectopic gastric mucosa, only 4 cases were positive on the Meckel's scan. Conclusion : In cases of unexplained GI bleeding, obstruction, or inflammation diagnostic workup should be carried out to rule out Meckel's diverticulum. Laparoscopy, high resolution ultrasonography and computed tomography of the abdomen may be indicated in the assessment of pediatric patient with lower GI bleeding, especially in patients with suspected bleeding from Meckel's diverticulum showing negative Meckel's scan.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.