• Title/Summary/Keyword: 보호장구

Search Result 75, Processing Time 0.026 seconds

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Changes in Quality of Citron Juice by Storage and Extraction Conditions (유자과즙의 저장 및 착즙조건에 따른 품질변화)

  • Park, Kee-Jai;Jung, Sung-Won;Kim, Jong-Hoon;Jeong, Jin-Woong
    • Applied Biological Chemistry
    • /
    • v.38 no.2
    • /
    • pp.141-146
    • /
    • 1995
  • Changes of physicochemical properties of citron juice prepared by two different extraction methods, rotary-crushing and belt-pressing method, were investigated during the storage at $5^{\circ}C$ and $-20^{\circ}C$. Temperature drop of citron juice extracted by belt-pressing method was faster than that of citron juice prepared by rotary-crushing method and its freezing point was $0.8{\sim}0.9^{\circ}C$. During the storage, pH of stored citron juice with rotary-crushing method was increased up to 3.5 after 6 months storage while that of citron juice extracted by belt-pressing method was not changed significantly during the same storage time. Acidity of rotary-crushed citron juice was reduced a little more than that of belt-pressed citron juice during the storage. However, changes of soluble solid content were influenced largely by the storage temperature than by the extraction method. Contents of formol nitrogen and vitamin C were reduced remarkably in all of stored citron juice and $92{\sim}82%$ of farmol nitrogen and $72{\sim}43%$ of vitamin C were remained after 6 months of storage. Among the changes of color value, L values were reduced in the whole stored citron juice and a and b value had a different change pattern respectively according to the extraction and storage temperature. Changes in the content of both amino acid and fatty acid compositions was also observed after same storage period. Especially, in the case of change of fatty acid composition, content of linoleic acid and linolenic acid were reduced after 6 months storage, while those of palmitic acid, stearic acid and oleic acid were increased.

  • PDF

Development of Evaluation Index for Infection Control and Prevention at Dental Hospital and Its Validity Verification (치과의료기관 감염관리 평가지표 개발 및 타당성 검증)

  • Bae, Sung-Suk;Lee, Myung-Sun
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.254-263
    • /
    • 2013
  • This study is to develop an evaluation index for infection control and to verify its validity by examining each set of weighted data collected from 121 infection control personnel at dental hospitals who agreed to the preliminary survey and advisory. The study was conducted from 14th December, 2010 to 31st January, 2011, and PASW Statistics 18.0 and AMOS 5.0 had been used for the statistical data analysis. As a result of the study, five evaluation factors with 21 sub-indicators have been identified at structural level, eight evaluation factors with 32 sub-indicators at processing level, and one evaluation fact with five sub-indicators at resulting level, total 14 evaluation factors with 58 sub-indicators throughout all levels. The path analysis added on the result that 'standard precautions ($x_1$)', 'infection control support system ($x_2$)', 'internal and external characteristics ($x_3$)' are exogenous variables that affect on other variables, and 'standard infection control ($y_1$)','Organization equipment management handwashing ($y_2$)', 'environmental infection control ($y_3$), 'personal protective equipment ($y_4$)', 'waste and laundry management ($y_5$)' are endogenous variables that are infulenced by others. The standardized metrics are more needed than anything else when examining on infection control. This study attempts to develop proper dental infection control metrics adequately adjusted for domestic circumstances, and therefore to contribute to effective systematic management and decision-making in infection control.

A Study on the Guardian's Perception of Attending Patient in Pediatric Radiography (소아 방사선 검사 시 보호자 참여에 대한 인식도 조사)

  • Kwak, JongHyeok;Jeong, JaeBeom
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.189-201
    • /
    • 2014
  • The purpose of this study was to survey guardian's opinion on assisting pediatric radiography and their level of awareness of radiation, improving the quality of pediatric radiography. In this study, the recognition was analyzed for 210 parents of child patients in Pusan National University Hospital from August 20 to September 15, 2013. A total of 66.2 percent of the respondents said they had participated in pediatric radiography in the past. The reason why they did is "Radiologist's request", the highest. According to the survey, 84.3 percent said they thought it is necessary to attending patient in pediatric radiography. "The stability of the child" is the reason for it. And respondents who thought there's no need to do that answered back, the reason for this is "Radiologist's work." There was a significant difference on the psychological state for the medical radiation by gender and child age. (p<0.05) In the analysis of recognition for the radiation, there was the significance by gender and education. (p<0.05) Regarding the awareness of the radiation protector, there was a statistical significance in age, gender, child age and education. (p<0.05) Considering the results, pediatric patient's guardians recognized that it is necessary to attend a child on X-ray for their child's stability and accurate exam above all. It must make guardians wear X-ray protector and radiologist should let the guardians recognize the X-ray examination method, before starting pediatric x-ray. It needs to improve the atmosphere of the examination room and to be considered to take visual and auditory approaches in comfort for reducing the children's fear and anxiety.