• Title/Summary/Keyword: 보철

Search Result 5,156, Processing Time 0.027 seconds

ORAL REHABILITATION OF UNSTABLE OCCLUSION DUE TO SEVERELY DESTRUCTED FIRST PERMANENT MOLARS (제1대구치의 광범위 치관파괴로 인한 불안정한 교합의 재건)

  • Baik, Byeong-Ju;Lee, Sun-Young;Kim, Jae-Gon;Jeon, So-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.204-209
    • /
    • 2003
  • A 9-year old boy visited Department of Pediatric dentistry, Chonbuk National University Hospital due to unstable occlusion. He had permanent 1st molars destructed severely by dental caries and lost vertical stop. He could not occlude in the same position on closing of the jaw since he could not find his centric occlusion. The treatment plan was made, which was oral rehabilitation with crown restorations on permanent 1st molars based on clinical and radiographic examinations and centric relation of the jaw. Treatment plan consisted of endodontic treatment, crown lengthening and restoration of the occlusal vertical dimension (OVD) with gold crown by 3mm-increase of OVD. After endodontic and periodontal treatments, temporary crowns made of acrylic resin were set for assessment of tolerance to an increased OVD. After a month for tolerance, final prosthetics were made and set temporarily. In a month, gold crowns were set finally. Immediately after setting, the patient showed anterior open bite, but at the appointment after 4 months, he showed normal overjet, overbite and stable occlusion.

  • PDF

TRANSITIONAL TREATMENT OF AMLEOGENESIS IMPERFECTA IN MIXED DENTITION: A CASE REPORT (혼합치열기에 있는 법랑질형성부전증 환아의 이행적 치료)

  • Hwang, Ji-Young;Choi, Yeong-Chul;Kim, Kwang-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.601-606
    • /
    • 2009
  • Amelogenesis Imperfecta (AI) is a genetic disorder which retards the development of enamel and it can be classified into three types: hypoplastic, hypomaturation, hypocalcified type. This can occur both in deciduous and permanent dentition. A 8 year 8 month old patient with a chief complaints of delayed eruption on upper anteriors, calculus deposit on lower anteriors and anterior openbite visited the clinic. Anteriors had thin layer of enamel and were very narrow. Especially lower anteriors had rough surface and were in bad shape. Teeth were very hypersensitive to thermal changes. Upper and lower first molars showed severe attrition on the occlusal surface. Radiographs also verified hypoplastic enamel in the whole dentition including the teeth in the tooth bud. The patient was diagnosed as hypoplastic AI, and is being treated at the pediathc and prosthodontic department of the Kyunghee dental university hospital. To improve the function, esthetics, hypersensitivity of the AI patients, restorations on the posteriors and the anteriors with oral hygiene instruction are necessary, Constant follow-up check is needed until full growth and after full growth, cooperative care with the other department is needed.

  • PDF

A COMPARATIVE STUDY OF THE SHEAR BOND STRENGTH AND ADHESIVE FAILURE PATTERN OF METAL BRACKETS BONDED ON NATURAL TEETH AND PORCELAIN TEETH (자연 치관과 포세린 치관상에서 교정용 브라켓 부착시 전단 결합 강도와 파절 양상에 관한 비교 연구)

  • Lee, Hyun-Sun;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • Orthodontic brackets often need to be bonded to porcelain such as porcelain fused to metal crowns and porcelain jacket crowns. The purpose of this study was to evaluate the clinical usability of direct bonding system on porcelain teeth by measuring shear bond strength according to various conditions and observing adhesive failure patterns. The specimens, 20 maxillary premolars and 80 porcelain teeth that were produced by duplication of the labial surface of a maxillary first premolar were used and randomly divided into four groups of twenty teeth each. The 5 different preparation procedures tested: (1) application of 37% phosphoric acid on natural teeth, (2) sandblasting on porcelain surfaces, (3) sandblasting and application of 9.6% hydrofluoric acid on porcelain surfaces, (4) sandblasting and application of silane on porcelain surface, (5) sandblasting and application of 9.6% hydrofluoric acid and silane on porcelain surfaces. The metal brackets were bonded with Transbond $XT^{(R)}$ bonding material. The shear bond strength was tested by the micro universal testing machine(Kyung-Sung, Korea) and the amount of residual adhesive on the tooth surface after debonding was examined by stereoscope and assessed with an adhesive remnant index. The results of this study suggest that the direct bonding system on porcelain teeth with sandblasting, HF and porcelain primer is clinically useful.

  • PDF

Improvement of Articulation Disorder Using Flexible Partial Denture in Intellectural Disability Patient with Missing Lower Incisors (하악 전치부 상실로 인한 조음장애를 보이는 경도 지적장애 환아에서 탄성의치를 통한 조음능력의 향상)

  • Choi, Haein;Choi, Byungjai;Choi, Hyungjun;Song, Jeseon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.306-313
    • /
    • 2013
  • Speech is complex psycho-physiological mutual process which includes many orofacial organs. Especially, teeth play an especially important role as an articulation organ in conjunction with the lips and tongue. When teeth are missing, the position of tongue and mandible is adjusted to produce correct sound. If a patient's adaptive function is inadequate for modification of malocclusion, prosthodontic and orthodontic interventions are necessary. Missing teeth of young patients should be reconstructed bacause it can cause malocclusion, decreased masticatory efficiency, articulation disorders, esthetic problem, and temporomandibular disorder. Valplast$^{(R)}$(Valplast International Corp, New York, USA) flexible denture is useful for rehabilitation due to its excellent physical properties, esthetics, and small volume. This case is regardingan intellecturally disabled patient with anarticulation disorder caused by missing lower incisors due to trauma. The patient showed improvement in articulation by using flexible partial denture. The purpose of this report is to figure out the influence of missing lower anterior teeth on articulation.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

Flexural characteristic changes of fiber reinforced composite $(Fibrekor^{(R)})$ according to water absorption (물 흡수에 따른 fiber reinforced composite $(Fibrekor^{(R)})$의 굽힘 특성 변화)

  • Kim, Sueck-Bum;Kim, Min-Jeong;Kim, Kyung-Ho;Choy, Kwangchul
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.361-370
    • /
    • 2005
  • Fiber reinforced composite (FRC) has been widely used in operative and prosthetic fields of dentistry and its use is expanding into the orthodontic field. The purpose of this study was to examine the changes of flexural properties of FRC reinforced with silica glass fiber (FibreKor, Jeneric/Pentron Inc.. Wallingford. U.S.A.) according to the duration of water absorption. Specimens were grouped according to their shape as round and rectangular cross sections, and were immersed in distilled water at room temperature $(23^{\circ}C)$ for 0 hour 1 hour 1 week. 15 days, 1 mouth and 3 mouths. The number of specimens was 5 for each duration and bending test was done using a torque tester The flexural stiffness after 24 hour water immersion was reduced to 59% for round specimens and 25% for rectangular specimens and after 3 mouths of water immersion it was reduced to 29% and 19% stiffness of the 0 hour-specimen respectively Yield flexural moment after 24 hour water immersion was reduced to 45%for round specimens and 76% for rectangular specimens and after 3 months of water immersion it was reduced to 29% and 60% stiffness of the 0 hour-specimen respectively Ultimate flexural moment after 24 hour water immersion was reduced to 35% for round specimens and 76% for rectangular specimens and after 3 mouths of water immersion it was reduced to 25% and 37% stiffness of 0 hour-specimen respectively. Those results suggested that the flexural stiffness of FibreKor decreased greatly after initial water immersion. Consequently, further research for the maintenance of strength against water will be necessary

The comparison between 2 wide implants and 3 regular implants in mandibular posterior area (하악 대구치부위의 고정성 보철물에서 2개의 장폭경과 3개의 표준 임프란트의 비교)

  • Yoo, Ho-Sun;So, Sung-Soo;Han, Dong-Hoo;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.577-588
    • /
    • 2002
  • Osseointegrated implants have been established as the standard treatment modality for full/partial edentulous patients since the 1960's, and the long term results for full edentulous patients have proven to be successful. Based on these results osseointegrated implants are now widely used for partial edentulous patients. There has been an increased interest towards the efficacy of wide implants, despite many reports mentioning the lower success rate of wide implants compared to regular implants. Recently, mandibular molar area defects are commonly restored using 2 wide implants, but it is not determined whether which treatment modality-3 regular implants or 2 wide implants-shows superior success rate. In this study, 2 wide implants and 3 regular implants used for the restoration of mandibular molar area are used to compare the survival rate of 1-4 years, and to analyze and compare the failure factors. The following conclusions could be drawn from this study. 1. Wide implants and regular implants showed 94.5% and 97,6% of survival rate respectively. After prosthodontic work, the survival rate was 100% and 98.1% for wide implants and regular implants respectively. 2. 5 failed implants have been removed. 2 wide implants and 1 regular implant have been removed due to failure of osseointegration. 1 wide implant was removed due to abscess formation caused by over-heating, and 1 regular implant was removed due to mechanical failure caused by over-loading within the first year of function. 3. No statistically significant difference was observed with respect to the amount of marginal bone loss of wide and regular implants.(P>0.05) In conclusion, restoration of the mandibular molar area using 3 regular implants was found to be a good treatment modality, and 2 wide implants could he considered a good treatment modality when success factors are taken into account.

Detection Rate of Periodontopathogens Associated with Cardiovascular Diseases in Denture. (의치 표면에서 심혈관질환과 관련된 치주질환 원인 세균의 검출)

  • Lim Mi-Young;Kim Hwa-Sook;Jeong Jae-Heon;Yang Ji-Youn;Oh Sang-Ho;Kook Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.40 no.3
    • /
    • pp.237-243
    • /
    • 2004
  • The aim of this study is to investigate the detection rate of putative periodontopathogens, Porphyromonas gingivalis, Tannerella forsythia, and Actiobacillus actinomycetemcomitans, related to cardiovascular diseases(CVD). Plaques were sampled from 15 subjects (4 sites of denture base and/or tooth) with sterilized explorers and were transported in IX PBS. The detection of periodontopathogens was performed by polymerase chain reaction with species-specific primers based on 16S rDNA. The PCR products were cloned into pGEM-T easy vector and its nucleotides were sequenced in order to confirm the specificity. Our data showed that the detection rate of P. gingivalis and T forsythia in denture base of edentulous patients was 25% and 75%, respectively. And the detection rate of P. gingivalis and T.forsythia in denture base of patient having one more tooth was 91%. The results indicate that plaque of denture base may serve as reservoirs of oral bacteria related to CVD.

Evaluation of shear bond strength between metal core fabricated by 3D printing and dental porcelain (3D printing으로 제작된 금속 코어와 치과용 도재 간의 전단결합강도 평가)

  • Jung, Jae-Kwan;Lee, Su-Ok;Kim, Ki-Baek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2585-2592
    • /
    • 2015
  • The purpose of this study was to evaluate the shear bond strength between metal core fabricated by 3D printing and dental porcelain. Thirty metal cores were fabricated(cast 15ea, 3D printing 15ea). The porcelain for each group was builded to the metal core. Sample was loaded to shear force(crosshead speed 1mm/min) in a universal material testing machine. The fracture samples were analyzed failure aspect. The means were statistical analyzed using by Mann-whitney test(${\alpha}=0.05$). The period of experimental(metal cores fabrication, dental porcelain build up, data analysis, statistical analysis, failure aspect analysis and others) for this study took six months. The $mean{\pm}SDs$ of shear bond strength was $50.14{\pm}1.60MPa$ for the cast group, and $54.36{\pm}3.18MPa$ for the 3D printing group(p=0.035). The failure aspect showed mixed failure. As a results, metal cores fabricated by 3D printing method were clinically acceptable range.