• Title/Summary/Keyword: 보철물적합

Search Result 119, Processing Time 0.033 seconds

Effect of machining precision of single ceramic restorations on the marginal and internal fit (단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향)

  • Son, Keunbada;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks and to evaluate the correlation. Materials and methods: Single restorations were designed using a CAD software program. The crown designed model file was extracted from the CAD software program. Three types of lithium disilicate blocks (Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA) were milled using a milling machine. For the fabrication of the crown scanned model file, the intaglio surface of the restoration was digitized using a contact scanner. Then, using the three-dimensional inspection software (Geomagic control X; 3D Systems), the process of the overlap of the crown designed model and the scanned model and 3-dimensional analysis was conducted. In addition, the marginal and internal fit of the crowns was evaluated by a silicone replication method. The difference among three types of single ceramic crown was analyzed using a Kruskal-Wallis H test, and Spearman correlation analysis was performed to analyze the correlation between machining precision and fitness (α=.05). Results: There was a significant difference in the machining precision and the marginal and internal fit according to the type of ceramic block (P<.001). In addition, the machining precision and the marginal and internal fit were positively correlated (P<.001). Conclusion: The marginal fit of crowns fabricated according to the types of ceramic blocks was within the clinically acceptable range (< 120 ㎛), so it can be regarded as appropriate machining precision applicable to all clinical as aspects in terms of the marginal fit.

Removable prosthetic rehabilitation in patient with maxillofacial defects caused by gunshot: A case report (총상으로 인한 악안면 결손을 가진 환자에 대한 가철성 보철물 수복증례)

  • Lee, Donggyu;Kang, Jeongkyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.198-204
    • /
    • 2017
  • Maxillofacial defect comes from congenital defect, trauma and surgical resection. Patients with intraoral defect are commonly related to maxillary defect and they need prosthetic rehabilitation. Functional reconstruction of partially edentulous mandible has many limitations. However, if both condyles are intact, maxillofacial prosthesis using partial denture give competent results. In this case, a patient of 58 year-old male has a defect on palate and left mandibular posterior teeth from gunshot. The maxillary defect of this patient is Class IV according to Aramany classification and the mandibular one is Type V according to Cantor and Curtis classification. For retention of the obturator, remaining teeth are fully utilized and artificial teeth are arranged harmoniously to provide stable occlusion. Mandibular RPD covered limited range of deformed soft tissue derived from mandibular resection surgery. With these treatments, the patient in this case showed improvements in mastication, swallowing and speech.

The effects of dental prostheses to the quality of life among the elderly (일부 노인의 치과보철물 상태가 구강건강관련 삶의 질에 미치는 영향)

  • Hur, Ik-Gang;Lee, Tae-Yong;Dong, Jin-Keun;Hong, Song-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.101-110
    • /
    • 2010
  • Purpose: This study has been conducted in order to examine the oral health status and dental prostheses status, and the effects of dental prostheses to the oral health related quality of life among the elderly using social welfare centers. Material and methods: For this purpose, the researcher conducted a questionnaire survey and oral examination of 275 samples of old persons using 7 social welfare centers located in Daejeon metropolitan city. The oral health related quality of life was measured by GOHAI (Geriatric Oral Health Assessment Index). Results: 1. The less age and the more education and the more subjective economic status and living with spouse of family status, the higher GOHAI showed. 2. Mean age of first using of removable denture is 62.11 years old and average life cycle of removable denture is 10.76years. 57.5% of study subjects use removable denture and complete denture user of study subjects are 13.8%. 3. In the case that they use fixed prostheses rather than removable ones and in the complete denture they use both sides (upper and lower) rather than single side, showed higher GOHAI. 4. In the case that they showed higher degrees of satisfaction with dental prostheses and can use them always and showed no necessity for new dental prostheses and denture adaptation is good, GOHAI showed higher. Conclusion: In order to improve oral health related quality of life among the elderly who have many missing teeth, it is required to restore their masticatory ability to the normal level by restoring the missing teeth which has lost its function through providing proper dental prostheses.

Esthetically improved complete denture by gingival shade alteration: a case report (무치악 환자에서 치은의 색조 개선을 통해 심미성을 향상 시킨 총의치 수복 증례)

  • Yim, Soo-Hyun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.239-245
    • /
    • 2014
  • Complete denture prosthodontics includes replacement of natural teeth and associated maxillary and mandibular structures for full edentulous patients. The final objectives of prosthodontic treatment include esthetic and functional rehabilitation. Because the esthetic demand of senior patients has increased esthetic requirement should not be overlooked in denture treatment. In complete denture treatment, attempts have been made to reproduce tooth wear, arrangement, recession of cervical gingiva, staining, improved gingival shade and so on. This 61 year old female patient came to the Department of Prosthodontics with the chief complaint that dentures made 5 years ago in a local clinic were broken and did not fit well. The patient put more emphasis on fabrication of natural and esthetic dentures than recovery of masticatory function. Remake of maxillary complete denture and mandibular implant retained overdenture was planned. In order to create esthetic and natural contour, Aesthetic Color Set Easy system$^{(R)}$ (Candulor dental GmbH, Wangen, Germany) was used to make complete dentures reproducing various gingival shades. Patient's esthetic satisfaction was high. When complete denture prosthodontics treatment involves appropriate expression of individual characteristics in addition to proper selection of esthetic materials, treatment will give satisfaction to both dentist and patient.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

Artificial Trachea Covered by Ipithelium (상피세포 피복 인공기관의 개발)

  • 김광택;이윤신
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.739-746
    • /
    • 1997
  • A variety of experiments concerning the development of ideal prosthetic grafts for correcting circumferential tracheal defects have been performed. The requirements for an ideal tracheal prosthesis are impermeability to air, consistency to prevent collapse, and acceptance by the host tissue causing a minimum inflammatory reaction, allowing fibroblastic infiltration and epithelialization. The synthetic material, polyurethane(PU), is known as a biocompatible polymer with an inert component. In this study, the tracheal prosthesis was made from microporous PU(30 micrometer in diameter) coated with gelatin and reinforced with isoplastic rings. This procedure provides the prosthesis with a compression strength. The out side diame er of the prosthesis was 20 mm with a length of 30 mm. The gelatin used in the study was obtained from pig skin and immobilized and cross-linked by irradiation(60 Co gamma ray) to promote host tissue incorporation and render the prosthesis epithelization after implantation. Animal experiments using 10 mongrel dogs were performed to compare three kinds of prosthesis; gelatin coated polyurethane graft, uncoated polyurethane graft, and prosthesisf pericadium complex graft. After 6 weeks of implantation, the epithelialization of implants was seen on the gelatin-coated and prosthesisfpericadium complex grafts. Implanted prosthesis were complicated by airway obstruction due to anastomosis granuloma. Early tracheal stenosis was found in the uncoated graft group. Two kind of anastomosis techniques were tested on the gelatin-coated prosthesis. Everted anastomosis resulted severe granuloma than the inverted anastomosis. In the prosthesislpericadium complex graft, bacteria and inflammation at a anastomotic site was found. Based on these results, gelatin coated porous polyurethane trachea prosthesis is biocompatible and may be useful in clinical application with further investigation.

  • PDF

Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth (지대치 변연 형태에 따른 수작업과 CAD/CAM으로 제작한 coping 패턴의 적합도 비교)

  • Han, Min-soo;Kwon, Eun-Ja;Chio, Esther;Kim, Si-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6611-6617
    • /
    • 2015
  • The purpose of this study is to compare the marginal and internal fit of metal and zirconia coping which is fabricated by manual and CAD/CAM(Computer Aided Design/Computer Aided Manufacturing). The model is prepared with Urethane material and two abutment teeth are fabricated with a knife and chamfer margin. Silicon replica technique is used to measure the marginal fit of manually fabricated and the CAD/CAM coping. Internal fitting level is measured with a microscope and the image is captured with a CCD camera. The distance between abutment teeth and coping is measured with a callibrated image analyzer software; marginal opening (MO), marginal gap (MG), internal gap (IG) at maximum curvature area, axial gap (AG), and occlusal gap (OG). Two-way ANOVA test is applied to compare fabrication technique and to analysis of abutment pattern. In addition, one-way ANOVA and Scheffe's test is used to analyze each parameter of the test. The result shows that the fit is < $120{\mu}m$ except OG of CAD/CAM and MO of knife margin. The CAD/CAM fabricated coping showed higher fit level at chamfer margin. However, knife margin showed better fitness compared to chamfer margin at MG. AG showed the minimum dimension with a constant result (< $38{\mu}m$).

CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES (악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.406-414
    • /
    • 2001
  • In recent decade, there has been a very rapid development in technical possibilities to provide patients with maxillofacial prostheses. Dr. Brenemark first introduced possibility of use of maxillofacial interosseous implant in patients with ablative tumor surgery in 1979. He did introduce the new type of maxillofacial implants system which widen the fixture flange on top of the bone. The advantages of fixed prostheses with implants were well known to various ways, easy to attach, keep clean prostheses, and not to disturb recipient bed. But there are some problems to install implants on maxillofacial regions, because mostly facial bone has very thin cortical bone and poor bone quality. It needs more retention between implant and bone which overcome that fault with fixture flange. To make maxillofacial prostheses, it should be understood general procedure of maxillofacial laboratory work. Ear and midface maxillofacial fabrication which include nose and eye defects will be described step by step.

  • PDF

Effect of Porcelain Firing Process on the Marginal and Internal Fit of Ni-Cr Alloy Metal-Ceramic Crown (도재 소성과정이 Ni-Cr 금속도재관의 변연 및 내면 적합도에 미치는 영향)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.405-410
    • /
    • 2014
  • The purpose of this study in vitro investigation was to compare the marginal and internal fit of Ni-Cr alloy metal ceramic crown before and after porcelain veneering. Furthermore, this study evaluated whether the influence of the porcelain firing on the precision of fit of dental prostheses. The maxillary right incisor was selected as an abutment for experiments. Ten working models were prepared. Ni-Cr alloy cores appropriate for each abutment were prepared by lost wax technique. The marginal area and four internal areas of the crowns were measured at two stages: before veneering process and after upper porcelain firing. Silicone replica techniques were used. The data were statistically analyzed with the paired t-test (${\alpha}=0.05$). $Mean{\pm}SD$ marginal and internal gap were $67.1{\pm}23.3{\mu}m$ for the nickle chrome alloy core group and $74.4{\pm}21.9{\mu}m$ for the metal ceramic crown group. There were statistically significant differences in all investigated areas (p<0.05). Within the limitations of this study, none of the Ni-Cr alloy metal crown values measured after porcelain firing process exceeded $120{\mu}m$, which is the clinically acceptable threshold.

A finite element analysis of implant-supported overdenture on the effect of anterior cantilever (임플랜트 bar overdenture에서 bar의 cantilever양이 임플랜트에 미치는 영향에 관한 삼차원 유한요소분석적 연구)

  • Jung, Tae-Wook;Kim, Young-Soo;Kim, Chang-Whe;Ling, Booi-Cie
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.1-17
    • /
    • 1998
  • 두개의 임플랜트로 지지되는 overdenture를 이용한 하악무치악환자의 치료법은 경제적이면서, 실용적인 치료로 인정을 받고 있다. 하지만 해부학적인 조건으로 임플랜트를 설측 혹은 후방에 식립해야 되는 경우에는 일반적인 bar설계는 bar가 구강저 상방을 지나게 되어 혀운동, 발음, 위생관리 등에 많은 문제점을 부여한다. 이에 대한 해결방법으로 전방부 치조제 상에 보철물의 회전을 허용하는 angular bar를 설계할 수 있다. 하지만 이 설계는 임플랜트에 불리한 moment를 유발한다. 그럼에도 불구하고 뛰어난 유지력과 지지능력, 경제적인 면 때문에 angular bar는 임상에서 많이 사용되고 있다. 이에 본 연구는 angular bar의 전방 cantilever양을 달리하여 임플랜트 및 주변조직에 미치는 영향을 삼차원 유한요소분석법을 통해서 알아보고자 하였다. 이공사이의 하악골을 단순화시킨 준하악골모형에 직경 3.75mm인 브로네마르크 임플랜트 2개를 길이가 13,15mm인 경우로 설정하여 제 1소구치 부위에 식립하였다. 두 임플랜트를 연결하는 bar는 전방부 cantilever양을 0-5mm, 1mm씩 하여 6가지 경우를 가정하고 제작하였다. 각각 bar 중앙부에 수직압 (90도) 35N, 경사압(120도) 70N, 수평압(0도) 10N을 가하였으며 이때 나타나는 응력 분산형태와 임플랜트의 골유착에 불리하게 작용하는 최대주응력(인장력)과 변위량을 살펴보았다. 연구결과 다음과 같은 결론을 얻었다. 1. Cantilever양이 증가할수록 주변피질골과 임플랜트로 응력이 집중되었으며 상부 보철물의 변위량도 커졌다. 2. Cantilever양에 대한 수평압의 영향은 크지 않았으며 임플랜트 길이가 긴 것이 변위량과 응력이 작았다. 3. 경사압에 대한 응력의 변화는 cantilever양의 증가에 따라 급격히 증가하는 양상을 띠었으며 임플랜트길이가 응력 및 변위의 양에 미치는 영향은 없었다. 4. 수직압에 대한 응력의 변화는 초기에는 완만한 증가를 보이다가 일정 시점 지난 후에는 증가율이 커지는 경향을 띠었다. 증가현상이 두드러지기 전에는 길이의 증가가 응력의 분산효과는 가져왔으나 이후에는 길이의 응력분산 효과는 없었다. 5. 응력분포양상은 cantilever양이 증가할수록 골조직을 통한 분산정도는 작아지고 특정부위의 피질골과 임플랜트, 상부보철물에 집중되는 경향을 보였다. 6. 임플랜트와 주변 골조직으로의 응력분산능력이 예후를 좌우한다는 점에서 angular bar는 적합치 못하며 부득이한 경우는 임플랜트 길이를 길게 하고 최대한 3mm이내로 cantilever양을 제한하는 것이 추천된다.

  • PDF