• Title/Summary/Keyword: 보철물적합

Search Result 119, Processing Time 0.038 seconds

REMOVABLE FLEXIBLE DENTURE FOR CHILDREN WITH OLIGODONTIA : A CASE REPORT (탄성의치를 사용한 부분무치증 환아의 보철적 수복)

  • Kim, Jin-Young;Lee, Kwang-Hee;La, Ji-Young;Lee, Dong-Jin;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.150-156
    • /
    • 2009
  • Objectives : The conventional removable appliance, composed of wires and acrylic resin, had unaesthetic results and poor retention. The flexible denture, as an alternative, presents improved aesthetics with the thin and strong resin retentive area. In addition, it also enhances patients' sensory function as a result of decreased volume of denture base. The flexibility of the flexible denture reduces the possibility of fracture and distributes the masticatory forces transmitted to the abutments and residual bone tissue. This report describes a 10-year-old girl and a 6-year-old boy with oligodontia treated with the flexible dentures as an alternative to conventional removable appliances. Methods : Impression was taken using alginate material and sent to a laboratory with the bite for fabrication of the flexible denture. Prior to try-in, the flexible denture was immersed in water at $90^{\circ}C$ for one minute and cooled. Impinging area of the denture was checked by $Fit-Checker^{(R)}$ and removed and the denture was delivered to the patient. Results : Both patients were satisfied with the flexible dentures, which presented improved retention and aesthetics. Conclusion : For patients with oligodontia, flexible dentures can be considered as a treatment of choice, which may replace the conventional denture.

  • PDF

Inhibition of Plaque Formation on the Titanium Surface by Anti-bacterial Varnish (항균제 처리한 titanium 표면의 치태형성 억제효과)

  • Chung, Hyun-Ju;Lee, Sang-Hyun;Kim, Yung-Jun;Williams, Ray C.
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.707-727
    • /
    • 2000
  • 매식된 인공치아의 성공을 위해서는 적절한 교합과 수동적 적합성을 갖는 보철물의 제작과 구강내 노출 직후부터의 세균성 치태조절이 요구된다. 본 연구는 전처리(passivation과 tridodecyl - methyl - ammonium chloride(TDMAC) 처리)가 다른 타이타늄 표 면에 chlorhexidine varnish와 테트라사이클린 을 도포시 약제의 방출역학을 알아보고 구강내 치태형성의 억제정도를 평가하기 위하여 시행 되었다. 이를 위해 방출용액으로 인산완충액 성분의 인조타액을 1일${\sim}$1개월간 매일 교환하여 약제농도를 측정하고 타이타늄 박막에 잔류한 약제 활성을 측정하였으며 항균제 도포한 타이타늄 원판을 부착한 장치를 구강내 위치시킨 1일${\sim}$3주 후 원판을 제거하여 주사전자현미경으로 세균 부착상을 관찰하였다. 테트라사이클린은 TDMAC 처리된 표면에서 $10{\sim}18$일까지 유효농도로 방출되었고 표면의 유효 항균 활성은 $3{\sim}4$주간 유지되었으며, chlorhexidine varnish 도포 시에는 TDMAC 전처리시 초기에 $3{\sim}7$일 간 증가한 유효 항균 활성을 방출하여 매식지대치 등에 이러한 항균제도포 시 매식치 주위환경에 항균활성 공급원으로 작용할 수 있음을 보였다. 주사현미경적 관찰시 모든 타이타늄 표면에서 구강내 위치 30분 후에는 세균이 부착되어 있지 않고 타액 단백질 성분에서 유래한 것으로 보이는 피막물질이 표면을 부분 또는 전면에 걸쳐 덮고 있었다. 구강내 노출 2시간 후 항균제 미도포 표본들에는 약간의 구균이 단층으로, $1{\sim}3$일 후에는 부분적으로 두꺼운 세균층을 형성하였고 7일 후에는 표면전체에 걸쳐 세균층이 덮여있었으며 주로 구균과 약간의 간균이 주종을 이루었다. 항균제 도포시 구강내 노출 1주일 이전까지는 미도포군에 비해 치태형성이 지연되는 경향을 보였지만 2주 이후에는 세균 수나 치태형성 양상이 유사하였다. 이 연구로부터 항균제 도포시 1주일 이전의 초기 치태형성을 감소시킬 수 있음을 알 수 있었으며 이러한 연구결과는 타이타늄 임프란트 지대치 표면에 항균제의 도포가 임상적으로 유용할 수 있음을 시사하였다.

  • PDF

Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin (복합레진으로 제작한 인레이 보철물 구조에 따른 교합면 부위의 2차원 변연 적합도 및 내면 부위의 3차원 정확성 분석)

  • Kim, Dong-Yeon;Lee, Tae-Hee;Park, Dong-In;Park, Jin-Young;Jeong, Il-Do;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.

The Environmental and Ecological Meaning of Bibo Landscape in Otgol Village (옻골마을 비보경관의 환경생태적 의미)

  • Jang, Byoung-Kwan;Whang, Bo-Chul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.2
    • /
    • pp.32-41
    • /
    • 2008
  • An empirical study and environmental and ecological analysis were conducted on Otgol Village(a village of the Gyeongju Choi's clan in Daegu) where an enclosed pond and groves are still observed. In particular, the enclosed pond and groves and village water system were investigated from an ecological perspective. The enclosed landscape is described based on feng shui principles and the environmental and ecological significance were examined. In general, the environmental and ecological significance is very broad; however, they were analyzed in terms of the quality of life as an empirical study as follows: First, water quality was measured to investigate the improvement of continuous water system functions. In other words, water quality was measured at East Valley(resting space), West Valley(living space), the enclosed pond where the two valleys merge, and the stream that flows out of the pond. Second, the climate functions of the enclosed groves that border the village were examined. In other words, temperature was measured in two places(200m distance from the center of the groves). Third, whether or not a sound ecosystem can be sustained was investigated. In other words, landscape ecological indicators were chosen and measured. The results are as follows: First, the enclosed pond played the role of purifying water quality. While the East Valley has been popular with men for its rock walls and torrents, the West Valley has been popular with women as a living space(ex: doing the laundry). Therefore, the difference of water quality can be explained. Second, since enclosed groves are in a small village forest, they are very weak in terms of being wind proof and temperature reduction effects. Instead, they play the role of the village boundary. Third, the groves are ecologically sound considering the landscape ecological indicators and are similar to ordinary traditional rural villages. In terms of the connection of the green zone, the village groves are well connected to the village boundary wood. If the village groves are restored, in particular, they would offer a decent habitat for grove creatures. According to this study, the traditional village space was formed upon the influence of Feng Shui theories that are based on environmental and ecological principles that focus on the harmony between humans and nature. From the environmental and ecological perspective, the enclosed pond and groves are important factors in building a sustainable village. The diverse water space would help to improve water quality and increase water volume by promoting the water circulation system. In addition, the village woods would surround the village and decrease the temperature and humidity difference between winter and summer. If the groves are small and badly damaged, however, they are meaningful only in dividing the region. The overall improvement of a forestation system and botanical composition may increase the biological diversity and promote the migration of species. Otgol Village has developed an enclosed landscape to improve the village environment. In other words, a sound and refreshing living environment can be developed when the natural ecological system is well understood and properly preserved. Additionally, this traditional village planning will be the environmental and ecological method. From the perspective of environmental ecology, therefore, a traditional village is recommended.

A Study on Corrosion according to Distance between Amalgam and Dissimilar Metals (아말감과 이종(異種)금속의 거리에 따른 부식에 대한 고찰)

  • Kim, Ju-won;Jeong, Eun-gyeong
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.103-109
    • /
    • 2004
  • The present study prepared 72 test samples - 24 made of amalgam alloy, 24 of Verabond (Ni-Cr alloy) for crown and 24 of Talladium $^{TM}alloy$ for denture - according to the manufacturers' manuals and general method in consideration of the width of the mesial-distal dental crown of the lower $1^{st}$ molar and MOD cavity in clinics, put them in a 200 ml beaker containing 80 ml of artificial saliva, and measured their galvanic corrosion at distances of 0 mm, 7 mm and 40 mm after 7 days. Isolated metals in the electrolyte such as Cu, Ag, Ni, Cr, Sn, Zn and Hg were quantitatively analyzed with Inductively Coupled Plasma - Atomic Emission Spectrometer (ICP-AES, JY-50P, VG Elemental Co. France), and from the results were drawn conclusions as follows. First, Cu, Sn, Ag, Hg and Zn were highly advantageous when amalgam contacted gold alloy compared to Ni-Cr alloy for crown and Talladium alloy for denture. In addition, although gold alloy was finest in terms of oral tissue and biocompatibility, it was most disadvantageous when it was with amalgam. Second, when amalgam contacted gold alloy, heavy metals such as Ni and Cr were not isolated at all because gold alloy did not contain such elements but Sn was isolated as much as $227.1{\pm}18.0035{\mu}g/cm^2$ although it was not included in the composition either. Hg was also isolated. These elements are assumed to have been isolated from amalgam itself. Third, when amalgam alloy was apart from gold alloy 0 mm, 7 mm and 40 mm, Cu and Ag showed significance but Hg did not. This suggests that gold alloy must not be used together with amalgam, and must not be used between dissimilar prostheses regardless of distance. Fourth, when amalgam alloy contacted Ni-Cr alloy for crown, Ag was not isolated from the amalgam, but Zn, Ni, Sn, Hg and Cu were isolated in order of quantity. Significance was observed according to distance - 0 mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Ni-Cr alloy for crown, the isolation Hg was less than that when amalgam alloy contacted Ni-Cr alloy for crown. Fifth, when amalgam alloy contacted Talladium alloy for denture, significance was observed at distances of 0mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Talladium alloy for denture, the isolation Hg was less than that when amalgam alloy contacted Talladium alloy for denture. Sixth, according to the result of ICPES test on Cu, Sn, Ag, Hg, Zn, Ni and Cr of amalgam alloy, gold ally, Verabond and Talladium alloy when these alloys contacted artificial saliva, significance was observed in Cu and Hg. Seventh, when amalgam alloy contracted two non-precious metals Ni-Cr alloy for crown and Talladium alloy for denture in artificial saliva, significance was observed in the isolated by-products of Hg, Ni and Cr according to distance.

  • PDF