• Title/Summary/Keyword: 보조장치

Search Result 868, Processing Time 0.023 seconds

Design and Implementation of Multi Exposure Smart Vehicular Camera Applying Auto Exposure Control Algorithm Based on Region of Interest (관심 영역 기반의 자동 노출 조절 알고리즘을 적용한 다중 노출 차량용 스마트 카메라의 설계 및 구현)

  • Jeon, Yongsu;Park, Heejin;Yoon, Youngsub;Baek, Yunju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.181-192
    • /
    • 2017
  • Recently, many researches are carried out for Advanced Driver Assistant Systems(ADAS). Especially, many studies are carried out to analyze the road situation using road images. In order to improve the performance of the road situation analysis, it is necessary to acquire images with appropriate exposure time. In this paper, we design and implement multi exposure smart vehicular camera which provides road traffic information to driver. Proposed device can acquire road traffic information by on-board camera and various sensors. And we propose an auto exposure control algorithm for the road environment to increase accuracy of image recognition. In addition, we also propose the switching ROI method that apply existing ROI techniques to overcome a limited computation power of embedded devices. We developed prototype of multi exposure smart vehicular camera and performed experiments to evaluate proposed auto exposure control algorithm and switching ROI method. The results show that the average accuracy of image recognition increased by 13.45%.

Sintering Properties of UO2+5wt% CeO2Compacts Using Microwave (마이크로파를 이용한 UO2+5wt% CeO2성형체의 소결특성)

  • Joung, Chang-Young;Lee, Su-Cheol;Kim, Si-Hyung;Kim, Han-Soo;Lee, Young-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.11
    • /
    • pp.797-803
    • /
    • 2004
  • The heat generation tests of SiC and MO$_2$ samples by use of a microwave heating system were carried out and UO$_2$+5 wt% CeO$_2$ pellets were sintered in a microwave furnace in an oxidizing atmosphere, by taking into account the characteristics of the microwave heating obtained from the heat generation tests. The characteristics of pellets sintered in a microwave furnace were analysed and compared with those of the pellets sintered in a conventional electrical furnace. The temperature of MO$_2$ pellets with microwave heating increased quickly with input power and the variation of output power depended on the reaction characteristics of SiC and MO$_2$ with microwave. The sintered density of UO$_2$+5wt% CeO$_2$ pellets sintered in the microwave furnace was lower about 2% T.D. than that of the pellets sintered in an electrical furnace with sintering parameters. The microstructure of pellets sintered in microwave furnace has a broader pore distribution but has a larger grain size than that of the pellets sintered in the electrical furnace.

Impedance Characteristics of 3 Layered Green Fluorescent OLED (3층 구조 녹색 형광 OLED의 임피던스 특성)

  • Gong, Do-Hun;Im, Ji-Hyeon;Choe, Seong-U;Park, Yun-Su;Lee, Gwan-Hyeong;Ju, Seong-Hu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.140-140
    • /
    • 2016
  • 유기전계발광소자 (Organic Light Emitting Diode : OLED)는 보조광원이 필요 없고 천연색 표현이 가능하며, 낮은 소비 전력 및 저전압 구동 등의 장점으로 이상적인 디스플레이 구현이 가능하여 차세대 디스플레이로써 많은 이목을 끌고 있으나 제한된 수명과 안정성의 문제점을 안고 있다. 따라서 OLED의 열화 원인을 분석하고 수명을 연장하기 위한 체계적인 방법과 기술 개발이 중요하다. Impedance Spectroscopy는 이온, 반도체, 절연체 등의 벌크 또는 계면 영역의 전하 이동을 조사하는데 사용될 수 있어, OLED에서도 Impedance Spectroscopy를 이용하여 전하수송과 전자주입 메커니즘 등 폭넓은 전기적 정보를 얻을 수 있다. 본 연구에서는 Impedance Spectroscopy를 이용하여 경과시간에 따른 OLED의 임피던스 특성을 측정하여 열화 메커니즘을 분석하였다. 본 연구에서 OLED는 ITO / 2-TNATA (4,4,4-tris2-naphthylphenyl-aminotriphenylamine) / NPB (N,N'-bis-(1-naphyl)-N, N'-diphenyl-1,1'- biphenyl-4,4'-diamine) / Alq3 (tris(quinolin-8-olato) aluminum) / Liq / Al으로 구성된 녹색 형광 OLED를 제작하였다. OLED의 전계 발광 특성을 측정하기 위한 전원 인가장치로 Keithley 2400을 사용하여 전압과 전류를 인가하였고, 소자에서 발광된 휘도 및 발광 스펙트럼은 Photo Research사의 PR-650 Spectrascan을 사용하여 암실 환경에서 측정하였다. 임피던스 스펙트럼은 컴퓨터 제어 프로그래밍이 가능한 KEYSIGHT사의 E4990A를 사용하여 측정하였다. 임피던스 측정 전압은 0 V부터 2 V 간격으로 8 V까지, 주파수는 20 Hz에서 2 kHz의 범위로 설정하여 측정하였다. I-V-L과 임피던스 특성은 24 시간의 간격을 두고 실온에서 측정하였다. 그림은 경과시간에 따른 녹색 형광 OLED의 인가전압 2 V, 6 V의 Cole-Cole plot을 나타낸 것이다. 문턱전압 미만인 인가전압 2 V에서는 소자를 통하여 전류가 흐르지 않아 큰 반원 형태를 나타내었고, 시간이 경과함에 따라 소자 제작 직후엔 실수 임피던스의 최댓값이 $8982.6{\Omega}$에서 480 시간 경과 후엔 $9840{\Omega}$으로 약간 증가하였다. 문턱전압 이상인 인가전압 6 V에서는 소자 제작 직후 실수 임피던스의 최댓값이 $108.2{\Omega}$으로 작은 반원 형태를 나타내나 시간이 경과함에 따라 방사형으로 증가하는 것을 확인 할 수 있었고, 672 시간 경과 후엔 실수 임피던스의 최댓값이 $9126.9{\Omega}$으로 문턱 전압 미만 일 때와 유사한 결과를 나타내었다. 이러한 임피던스의 증가 현상은 시간이 경과함에 따라 OLED의 열화에 의한 것으로 판단된다.

  • PDF

Development of Control Algorithms Considering the Effect of a Control Sampling Period on the Total Amount of Switching for a Switched System (컨트롤 샘플링 주기가 스위칭 시스템의 결합-분리 횟수에 미치는 영향을 고려한 제어 알고리듬 개발)

  • Joung, Jin-Wook;Chung, Lan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.67-76
    • /
    • 2009
  • Recently, the active interaction control (AIC) system was proposed as a semi-active control system. The AIC system consists of a primary structure and an auxiliary structure. The objective of the AIC system is to control the response of the primary structure through engagement and disengagement between the primary and auxiliary structures. Previous switching control algorithms have been shown to be effective in reducing the response of the primary structure. However, they have the main drawback of requiring an excessive engagement-disengagement frequency and high interaction force. In this paper, the regions in which the switching is activated and the regions in which the switching is deactivated are described separately, to effectively determine the engagement or the disengagement. The general relationship between the switching regions and the deactivated switching regions selected according to the engagement-disengagement conditions is described within the newly-developed comprehensive switching framework. The proposed engagement-disengagement conditions are designed within a comprehensive switching framework, to reduce engagement-disengagement frequency and interaction force. Furthermore, the effect of a control sampling period on the AIC system is explained in terms of the engagement-disengagement frequency. The effectiveness of the proposed algorithms and the effect of the control sampling period are considered for a single degree of freedom model under free vibration. It is observed that increasing the duration of stay by using a large control sampling period prevents the AIC system from activating the possible chance of switching. The proposed algorithms are shown to be effective, both in restricting ineffective switching and in reducing interaction force.

Synergistic Effects of N-methyl-2-pyrrolidone on Skin Permeation of a Hydrophobic Active Ingredient (N-methyl-2-pyrrolidone 제제의 경피흡수촉진효과)

  • Lee, Geun-Soo;Lee, Dong-Hwan;Kim, Kyoung-Bum;Ko, Hyun-Joo;Pyo, Hyeong-Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.36 no.2
    • /
    • pp.115-120
    • /
    • 2010
  • The formidable barrier property of the stratum cornemum and the high hydrophilicity of active ingredient make it difficult to permeate through the skin and reach to its site of action. The aim of this study was to investigate the effect of chemical penetration enhancers on the skin permeation of a hydrophilic cosmetic active ingredient, such as arbutin. The enhancing effects of N-methyl-2-pyrrolidone (NMP) on the permeation of a hydrophilic cosmetic active ingredient were evaluated by using Franz diffusion cell. The study indicated that NMP has considerable influence on the skin permeability. NMP was not only the most effective enhancer but also increased the skin permeability of arbutin approximately 1.3~1.5 fold compared with control without penetration enhancer. The lag time did not change with NMP, which suggested no effect of NMP on skin lipid fluidity. This suggest that arbutin co-permeated with NMP. The results indicate NMP is effective enhancer of a hydrophilic cosmetic active ingredient in penetration, with potential applications for drug delivery system.

Study on Phosphorus Removal in the Secondary Effluent by Flotation Using Microbubble Liquid Film System (미세기포 액막화 부상법을 이용한 하수 2차 처리수의 인 제거에 관한 연구)

  • Lee, Shun-Hwa;Kang, Hyun-Woo;Lee, Se-Han;Kwon, Jin-Ha;Jung, Kye-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.42-48
    • /
    • 2012
  • In this study, experiment on phosphorus removal was performed by using microbubble liquid film flotation tank with microbubble module. After dissolving gas and liquid in dissolving tank, microbubble liquid film system created microbubbles in equal size under fixed low pressure. After being passed through $A_2O$ and m-$O_3$ process, secondary treatment wastewater was used as influent in phosphorus removal process. When the T-P concentration of influent was 2.89 mg/L, alum(8%, 30 mg/L) was injected into a microbubble flotation tank, the treatment resulted 94% of T-P removal rate. Remaining T-P concentration was less than 0.2 mg/L, which is in accord with the effluent quality standard. Seasonal variations in water temperature showed no differences in T-P removal property. When the inflow concentration of SS was 1.0 mg/L or more, it served as coagulation nuclei in the coagulation process. In that condition, average T-P removal rate was higher than 97%. When 50% of floated scum was returned, coagulator Al included in scum assisted the injected coagulator and maximized the coagulation efficiency of pollutant. In such treatment, the T-P concentration was measured as 0.18 mg/L and satisfied the outflow water quality standard, which is 0.2 mg/L or less.

A Research for the pattern of the Instrument Panel Design of passenger cars (승용차 인스트루먼트 패널 디자인 유형의 연구)

  • Koo, Sang
    • Archives of design research
    • /
    • v.12 no.4
    • /
    • pp.99-108
    • /
    • 1999
  • The interior space in a passenger car is consisted with many partial elements, and the instrument panel is the most important part from all of them, which is designate the total image of the interior design and the space variation, drivability and safety of the interior space. ] The instrument panel of a passenger car in the early age had the concept of a wall between the engine room and the passenger cabin on which the instrument for the driver were fitted. Therefore the central mounting of the instruments was the typical feature regardless of the position of a driver seat. As the automobiles became more functional with many equipments, driver oriented instrument panel with energy absorbing materials had been developed, and that was the beginning of the various instrument panel design of these days. The recent instrument panels of passenger car have the tendency of going back to the central instrument mounting as it was at the past on a few cars for the strict safety regulation, a new production technology and for the enhanced drivability. It can be summarized into a few results as these with the analysis of a few recent instrument panels. -minimizing the total volume for the better frontal visibility. -energy absorbing and passive structures for the strict impact regulations. -revival of central instrument mounting for the convenience and safety through minimizing the difference of the focal length of a driver.

  • PDF

Superconducting Thick Film by Lateral Field Assisted EPD (측면보조전계 인가 전기영동전착 초전도후막)

  • 전용우;소대화;조용준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.679-685
    • /
    • 2004
  • Although the electrophoretic deposition method has the advantage of simple processing procedure, less fabrication facilities, and easier control for deposition thickness and wire length, providing economical and technical merits, it also has the disadvantages of cracking and porosity phenomena, requiring an improved processing method for higher particle density and constant particle orientation. we have developed an optimization method to increase the particle density and to unify its orientation, and have performed a study to overcome the cracking and porosity problems in the fabricated superconductor. In order to improve the surface uniformity and the conduction properties of the fabricated YBCO thick films, a system that applies alternate voltage vertically has been developed for the first time and applied to the electrophoretic deposition process. The applied alternate electric field caused a force to be exerted on each YBCO particle and resulted in a rotation of the particle in the direction of applied electric field, accomplishing a uniform particle orientation. We name this process as the shaky-aligned electrophoretic deposition method. For commercial utilization and efficiency, in this dissertation, alternating voltage of 60 Hz and 25 ∼ 120 V/cm was proposed to apply it as a subsidiary source for shaky-flow deposition so that the fabricated thin film showed uniform surface morphology with less voids and cracks and Tc,zero of 90 K and the critical current density of 3419 A/$cm^2$.

The Mid-term Results of Pulmonary Vein Isolation for Atrial Fibrillation associated with Mitral Valvular Heart Disease (승모판 질환에 동반된 심방세동에 대한 폐정맥 분리술의 중기성적)

  • Kim, Kyung-Hwan;Kim, Tae-Hun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.345-350
    • /
    • 2001
  • 배경: 항부정맥 술식으로서의 메이스 술식은 우수한 동율동 전환율을 보고 있으나, 술식의 복잡성과 상대적으로 긴 수술 시간 등으로 모든 환자들에게 적용할 수는 없기에, 일부 환자군에서 보다 간단한 항부정맥술인 폐정맥 분리술을 시행 받은 환자들을 대상으로 동율동 전환율 등의 수술 성적과 위험 인자 등에 대해 알아보고자한다. 대상 및 방법: 1995년 10월부터 1999년 2월까지, 폐정맥 분리술을 시행받은 96명의 환자들을 대상으로 후향적 연구를 시행하였다. 남자가 37명(38.5%), 여자가 59명(61.5%) 이었고, 평균 연령은 46.9$\pm$11.6세 이었다. 승모판 협착 환자가 50명(52.1%), 폐쇄 부전이 24명(25%), 협착과 폐쇄부전이 같이 있었던 경우가 22명(22.9%)이었다. 판막 술식과 폐정맥 분리술을 시행하고 좌심방이 제거술을 시행하였다. 모든 환자들은 술 후 6개월 내지 1년 이내에 외래에서 심전도와 심초음파를 시행받았다. 평균 추적 관찰 기간은 25.9$\pm$11.5개월 이었다. 술 후 최근 추적일까지 동율동으로 전환된 군과 안된 군으로 나누어 분석을 하였다. 결과: 조기 성적으로는 사망이 3명(3.1%), 술 후 6개월 이내의 추적관찰 유실이 2명(2.1%) 이었다. 조기 합병증으로 재수술이 필요 했던 출혈이 4례, 심폐바이패스 이탈 실패오 심실보조장치 등의 삽입이필요했던 경우가 1례, 뇌혈관질환 1례, 심근경색이 1례 등이 있었다. 만기 합병증으로는 동기능 부전 증후군으로 영구 심박동기를 삽입한 경우가 1례, 일시적인 뇌경색 1례 있었고 다른 판막과 연관된 합병증은 없었다. 동율동 전환 환자 수는 75명(82%)이었다. 동율동으로의 전환이 어려운 위험인자로 50세로 이상의 연령(p=0.03), 65mm 이상의 좌심방 크기(p=0.03), 동반 우심 술식 시행(p=0.02)등이 있었다 결론: 승모판 질환을 동반한 심방 세동 환자에서 폐정맥 분리술을 시행하여 만족할 만한 동율동 전환율을 얻을 수 있었다.

  • PDF

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF