• Title/Summary/Keyword: 보조장치

Search Result 872, Processing Time 0.024 seconds

Development of Trigger for Signal Storage Reflecting the Behavior Characteristics of the Free-Fall Cone Penetration Test System (자유낙하식 콘관입시험 시스템의 거동특성을 반영한 신호저장용 트리거 개발)

  • Kang, Hyoun;Shin, Changjoo;Kwon, OSoon;Jang, In Sung;Baek, Seungjae;Seo, Jung-min;Won, Sung Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.16-22
    • /
    • 2020
  • The Korea Institute of Ocean Science & Technology is developing a free-fall cone penetration test system (FFCPT) that can acquire the characteristics of the seabed surface soil. To obtain the data through the FFCPT, a method of storing the signals for the entire time or a method of storing the signal for user-defined time can be considered. For efficient data storage and management, it is advantageous that data be stored by user definition. Therefore, this study analyzed the basic behavior using the signal acquired through a sensor mounted in the FFCPT and developed a trigger method to recognize the start and end of data storage using a depth sensor. The start and endpoints of the fall were determined using the moving average difference of 3 and 0.03 seconds of the depth signal. A real sea-trial test was performed using the FFCPT, and the developed trigger was operated normally.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure (전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화)

  • Seok, Jin-Woo;Chernysh, V.S.;Han, Sung;Beag, Young-Hwoan;Koh, Seok-Keun;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.967-972
    • /
    • 2003
  • The inner-diameter 5 cm cold hollow cathode ion source was designed for the high current density and the homogeneous beam profile of ion beam. The ion source consisted of a cylindrical cathode, a generation part of magnetic field, a plasma chamber, convex type ion optic system with two grid electrode, and DC power supply system. The cold hollow cathode ion sources were classified into standard type (I), electron output electrode modified type (II). The operation of the ion source was done with discharge current, ion beam potential and argon gas flow rate. The modification of electron output electrode resulted in uniform plasma generation and uniform area of ion beam was extended from 5 cm to 20 cm. Improved ion source was evaluated with beam uniformity, ion current, team extraction efficiency, and ionization efficiency.

In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network (인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출)

  • 이혁수;이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.429-438
    • /
    • 1997
  • Mechanical valve is one of the most widely used implantable artificial organs of which the reliability is so important that its failure means the death of patient. Therefore early noninvasive detection is essentially required, though mechanical valve failure with thrombosis is the most common. The objective of this paper is to detect the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter(DaqBook 100) and the periodogram is the main algorithm for obtaining spectrum. We made the thrombosis models using pellethane and silicon and they are thrombosis model on the valvular disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The performance of the measurment system was tested firstly using 1 KHz sinusoidal wave. The measurement system detected well 1KHz spectrum as expected. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. We find that the secondary peak changes according to the thrombosis model. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network, which contains 7, 000 input node, 20 hidden layer and 1 output was employed The trained neural network can distinguish normal and valve with more than 90% probability. As a conclusion, the noninvasive monitoring of implanted mechanical valve is possible by analysing the acoustical spectrum using neural network algorithm and this method will be applied to the performance evaluation of other implantable artificial organs.

  • PDF

Evaluation of Electrohydraulic Left Ventricular Assist Device through Animal Experiment (동물실험을 통한 전기유압식 좌심실 보조장치의 성능 평가)

  • Choi, J.S.;Chung, C.I.;Choi, W.W.;Park, S.K.;Jo, Y.H.;Om, K.S.;Lee, J.J.;Won, Y.S.;Kim, H.C.;Kim, W.G.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.84-87
    • /
    • 1996
  • We have been developed electrohydraulic left ventricular assist device and done various in vivo evaluation on the device. Through the in vivo experiment conducted from Jan. 23, 1996 to Feb. 8, we could have experience of long-term evaluation fur the first time. The sheep used in this experiment had survived for 16 days. We used new actuator with reduced size and linear motion guide replacing oil box and ball bearings. Also, we used improved blood chamber with reduced size, reduced weight facilitating fixing the chamber to animal's body, and polymer sac having improved folding pattern. Against suction problem, we used absolute pressure limiter only. Motor current for driving this new actuator was not much higher than older one. Effective stroke volume was about 48 cc. Thrombosis was found around top area and peripheral boundary of the sac and valves. There was no sign of damage from suction problem in the atrium observed at autopsy. Main cause of death was presumed to be progressive formation of thrombosis in the cannulae. In this paper, the results of this experiment are documented.

  • PDF

A Study on the Braking Force Distribution of ADAS Vehicle (첨단 운전자 보조시스템 장착 차량의 브레이크 제동력 분배에 관한 연구)

  • Yoon, Pil-Hwan;Lee, Seon Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.550-560
    • /
    • 2018
  • Many countries have provided support for research and development and implemented policies for Advanced Driver Assistance Systems (ADAS) for enhancing the safety of vehicles. With such efforts, the toll of casualties due to traffic accidents has decreased gradually. Korea has exhibited the lowest toll of casualties due to traffic accidents and is ranked 32nd in mortality among the 35 OECD members. Traffic accidents typically fall into three categories depending on the cause of the accident: vehicle to vehicle (V2V), vehicle to pedestrian (V2P), and vehicle independent. Most accidents are caused by drivers' mistakes in recognition, judgment, or operation. ADAS has been proposed to prevent and reduce accidents from such human errors. Moreover, the global automobile industry has recently been developing various safety measures, but on-road tests are still limited and contain various risks. Therefore, this study investigated the international standards for evaluation tests with regard to the assessment techniques in braking capability to cope with the limitations of on-road tests. A theoretical formula for braking force and a control algorithm are proposed, which were validated by comparing the results with those from an on-road test. These results verified the braking force depending on the functions of ADAS. The risks of on-road tests can be reduced because the proposed theoretical formula allows a prediction of the tendencies.

Comparative study on the Shape between a Customized Finger Made by 3D Printing Technology, Real Small Finger, a plaster Small Finger, Based on CT Data (CT data 기반 3D 프린팅으로 제작된 Small Finger, 실제 Small Finger 그리고 석고 Small Finger 형상 비교 연구)

  • Choi, Hyeun-Woo;An, Do-Hyun;Rhee, Do-byung;Lee, Jong-Min;Seo, Anna
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.153-158
    • /
    • 2019
  • The purpose of this study is to compare and analyse the differences between a customized small finger made by 3D printing technology, a real small finger, and the other made from plaster of an orthotic company. The areas and the volumes of each cross-section were measured by Computer tomography(CT) and a 3D scanner and analysis of variance was performed to find out the differences of each shape. The areas of the point of 15.69mm, Distal Interphalangel Joints, were measured 30 times respectively using the caliper toll function of Picture Archiving Communication System(PASC) program. The volumes were measured by Configure Units of Meshmixer Program. There was no significant difference in the areas between three of them and there was 0.2 mm gap in the volume, which was more than the significance probability. Therefore, the result of this study shows the availability of finger orthoses made by 3D printing technology in the medical field.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

Hydrogen explosion effects at a containment building following a severe accident (중대사고시 수소폭발이 격납건물에 미치는 영향)

  • Ryu, Myeong-Rok;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • On March 11, 2011, a massive earthquake measuring 9.0 on the Richter scale and subsequent 10-.14 m waves struck the Fukushima Daiichi (FD) Nuclear Power Plant. The main and backup electric power was damaged preventing the cooling system from functioning. Fuel rods overheated and led to hydrogen explosions. If heat in the fuel rods is not dissipated, the nuclear fuel coating material (e.g., Zircaloy) reacts with water vapor to generate hydrogen at high temperatures. This hydrogen is released into the containment area. If the released hydrogen burns, the stability of the containment area is significantly impacted. In this study, researchers performed an explosion analysis in a high-risk explosion area, analyzing the hydrogen distribution in a containment building [1] and the effects of a hydrogen explosion on containment safety. Results indicated that a hydrogen explosion was possible throughout the containment building except the middle area. If an explosion occurs at the top of the containment building with more than 40% of the hydrogen collected or in the bottom right or left side of the of containment building, safety of the containment building could be threatened.