• Title/Summary/Keyword: 보일러 관

Search Result 55, Processing Time 0.025 seconds

Heat Transfer Characteristics of 0.5 t/h Class Non-Furnace Boiler with a Metal Fiber Burner (금속섬유 버너를 채택한 0.5 t/h 급 무연소실 보일러의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.215-220
    • /
    • 2011
  • A 0.5 t/h class non-furnace boiler has been developed with the aim of achieving a high efficiency and compactness. A metal fiber burner has been adopted so that a stable flame can be obtained. The tube banks are installed downstream of the burner. Bare tubes are used upstream, while finned tubes are installed downstream. The heat-transfer characteristics of the non-furnace boiler have been studies on the basis of the results of the numerical simulation as well as those of the experiment. Important design parameters such as the bulk temperature along the streamwise direction and the temperature of the fin tips have been evaluated using the CFD results and compared with the experimental data and the empirical correlations typically used for the design of the boiler.

Development of Mobile Robot Systems for Automatic Diagnosis of Boiler Tubes in Fossil Power Plants and Large Size Pipelines (화력발전소 보일러 튜브 및 대형 유체수송관 자동 진단을 위한 이동로봇 시스템 개발)

  • Park, Sang-Deok;Jeong, Hee-Don;Lim, Zhong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.254-260
    • /
    • 2002
  • In this study, two types of mobile robotic systems using NDT (Non-destructive testing) method are developed for automatic diagnosis of the boiler tubes and large size pipelines. The developed mobile robots crawl the outer surface of the tubes or pipelines and detect in-pipe defects such as pinholes, cracks and thickness reduction by corrosion and/or erosion using EMAT (Electro-magnetic Acoustic Transducer). Automation of fault detection by means of mobile robotic systems for these large-scale structures helps to prevent significant troubles without danger of human beings under harmful environment.

Analysis of Density Wave Oscillation in Boiler Furnace Wall Tubes with Parallel Channel Modeling (평행관 모델링을 통한 보일러 화로벽관 내 밀도파 불안정의 해석)

  • Kim, Jinil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • A numerical model was developed to predict the density wave oscillation (DWO) in the furnace wall tubes of a fossil-fired once-through boiler. The transient flow fields in the tubes were obtained using a 1D finite volume method in the time domain. A header model was also implemented to simulate the parallel tube connection of the wall tubes. The inlet and outlet mass flow variation in one of the parallel tubes was examined after a heat perturbation to find the DWO. After successful verification with experimental results reported in literature, the developed model was applied to the wall tubes of a 700-MW boiler furnace. In contrast to the simulation of Takitani's experiment, in which the unstable power thresholds tended to rise in the reduced bypass channel flow, no remarkable changes were observed in the power thresholds in the parallel channel modeling of the wall tubes of the boiler furnace.

A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler (보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究)

  • 김종보;한승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.699-705
    • /
    • 1985
  • Heat transfer characteristics in terms of the tube wall-temperature and the enthalpy have been investigated utilizing ribbed (rifled) tubes in order to enhance heat transfer performance. Considerations were given for the cases of smooth tubes in order to compare with the case of ribbed tubes. The tilt angle of the experimental tubes are from 0.deg. to 90.deg. , in order to simulate the boiler water tubes having 15.deg.-90.deg. inclined angle in boiler nose and studded tubes (burner zones), Natural convection and forced convection (Re=1810) conditions were considered in the experiments. The experimental results for the effect for the tube inclination through a natural convection and forced convection are presented and it is shown that ribbed tubes permit an appreciable increase in heat transfer coefficients and consequently it means substantial reductions in boiler water wall tubes and heat exchanger surface areas.

일본에서의 도시가스 안전대책

  • 관 정광
    • 보일러설비
    • /
    • s.20
    • /
    • pp.142-163
    • /
    • 1990
  • 금후 건물이나 기기의 성에너지화가 진척됨에 따라 에너지 수요를 둘러싼 에너지간의 경합이 더욱 심화될 것이 예상된다. 따라서 가스에너지의 메리트를 최대한으로 살리는 기술과 상품을 개발하여 마케팅활동의 일환으로 전개시키고 싶다. 여기서는 일본에서의 새로운 기기, 설비 및 금후의 기술개발을 중심으로 보고하고자 한다.

  • PDF

Heat Transfer Characteristics of 2 t/h-Class Modular Water-Tube-Type Boiler (모듈형 2 t/h급 수관식 보일러의 열전달 특성)

  • Ahn, Joon;Hwang, Sang-Soon;Kim, Jong-Jin;Kang, Sae-Byul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1127-1133
    • /
    • 2012
  • A finned-tube-type evaporator module has been proposed for a 2 t/h-class water-tube-type industrial boiler with multiple burners. The geometry of the fins was changed at each module to equalize the evaporation. The modules were designed by considering the energy balance at each row rather than by following a conventional bulk design procedure. The designed module was built into a 2 t/h-class water-tube-type boiler, and its performance was tested. A numerical simulation was also conducted to evaluate the two- or three-dimensional effects of factors such as the inlet conditions. The numerical simulation also included the conjugate heat transfer problem to predict the fin tip temperature. The heat transfer coefficient with fins is lower than that obtained from the empirical correlation of a bare tube. The fin tip temperature from CFD is higher than that from the analytical solution.

결론은 실천이다 - 고객만족통한 고객관계란

  • Seo, Pil-Hwan
    • 보일러설비
    • /
    • no.11 s.142
    • /
    • pp.166-167
    • /
    • 2005
  • "요즘 장사가 안되시죠?" 요즘 모두 다 불경기라고 한다. 하지만 장사가 잘되는 사람도 있다. 불경기 속에서도 장사가 잘되게 하는 비결이 무엇일까 필자 서필환씨는 23년간 한국타이어를 다니면서 고객과 직접 접촉하는 업무를 했다. 서씨는 입사이후 영업사원 교육담당을 거쳐 AS업무를 맡으면서 불만고객과 심하게 다툰 기억이 오늘의 대한민국 대표 CS클럽 회장으로 활동하는 기회가 되었다고 한다.

  • PDF