• Title/Summary/Keyword: 보이드 결함

Search Result 75, Processing Time 0.029 seconds

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

Development of inorganic thixotropic-grout for backfilling of shield TBM tail voids and its compatibility (쉴드 TBM 뒤채움용 무기계 가소성 그라우트의 개발 및 적합성 평가)

  • Kim, Dae-Hyun;Jung, Du-Hwoe;Jeong, Gyeong-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.3
    • /
    • pp.277-286
    • /
    • 2009
  • A suitability of a thixotropic grout developed in this study has been examined through laboratory tests on strength, segregation, and viscosity. The thixotropic grout is a mixture of two types of liquid components. The A-liquid component consists of cement, water, and MG-A and the B-liquid component consists of scarlet, water, and MG-B. Unconfined compressive strength of specimens prepared with a prefer mix-proportion satisfied a design criteria for the backfilling of tail voids. A material segregation phenomenon under water condition was not observed in the thixotropic grout whereas it was observed in the existing silica-type grout. In addition, viscosity tests have been rallied out on the thixotropic grout to verify the capability of a long-distance delivery in the field. Both the A-liquid component and the B-liquid component maintained a viscosity of below 2,000 cP for 120 minutes. This experimental result confirms that two liquid components guarantees a long-distance delivery in tile field application.

A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection (음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구)

  • 이덕진;신성권;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.68-74
    • /
    • 1999
  • Ths paper does acoustic detection of partial discharge using acoustic sensor in polymer. Time sequential rreasurement of acoustic emission characteristic obtained acoustic sensor deal with statistics process. and 5 characteristic quantities were introduced into this paper. Resulting fann analysis of $\psi$-AEA-n pattern (phase-acoustic emission amplitude-pulse number) and AE quantities ,it can know useful statistics quantities that AE average inception amplitude TEX>$(\overline{AEA_{inc}})$ and AE average maximum amplitude TEX>$(\overline{AEA_{max}})$ make diagnosis of the middle stage of deterioration, AE pulse number and AE average maximum phase $(\overline{\theta{max}})$ make diagnosis of the last stage of deterioration. it obtained that these AE quantities are useful for dias,mosis deterioration form experiment results.esults.

  • PDF

Considerations on correlation between partial discharge and breakdown using void-simulated defect (보이드 모의결함을 이용한 부분방전과 절연파괴와의 상관관계에 대한 고찰)

  • Lee, Tae-Seong;Jang, Su-Gil;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.21-22
    • /
    • 2011
  • In this paper, considerations on correlation between partial discharge and breakdown using void-simulated defect, investigating the characteristics of void discharges. For the purpose, the relationship between PDIV(Partial Discharge Inception Voltage) and BDV(BreakDown Voltage) was analyzed. As a result, it is noticed that the higher PDIV, the higer BDV.

  • PDF

Comparison and analysis of electrical treeing and PD distribution according to defects models (결함에 따른 전기트리의 발생양상 및 PD 분포 특성의 비교/분석)

  • Jeong, Hae-Eun;Park, Song-Hee;Lim, Kee-Joe;Kang, Soeng-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.497-498
    • /
    • 2006
  • 본 논문에서는 전력기기의 고체 절연물내에서 발생하는 전기트리의 진전양상 및 그에 대한 PD 분포 특성을 Hn(q), $Hn(\Psi)$, $Hq_{avg}{\Psi})$, $Hq_{max}(\Psi)$로 표현하였다. 또한 통계적 분포의 변화정도를 나타내어 정량적으로 확인을 하고자 하였다. 논문에서 사용한 트리 결함은 침-평판 트리, 보이드트리, 고체절연물내 이물트리 등 세 가지 경우이며, 각각의 트리 진전에 대한 특성은 서로 다른 특성을 보이는 것으로 나타났다.

  • PDF

Quantitative Evaluation of Flaw by Ultrasonic Spectroscopy (초음파 주파수 분석법에 의한 결함의 정량적 평가에 관한 연구)

  • 한응교;김성규;박준서;이범성;박익근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.1004-1010
    • /
    • 1992
  • In recent years, along with the development of ultrasonic probe with wide frequency range, the digitization of measuring instrument, and the development of operating process technics, it is possible to analyze ultrasonic pulse in frequency range. In this paper, applying to flaw model the ultrasonic spectroscopy method that can analyze ultrassonic pulse in frequency range, we examine the possibility of quantification of flaw and apply its result to the void and seperation in LSI package. Consequently, by using the change in frequency distribution and central frequency of sltrasonic pulse detected from flaw, the estimation of shape, size, and depth of flaw is possible. The change in central frequency is changed minutely by the sample materals and position of flaw, but changed mainly by the shape and size of flaw. And we can quantify the shape and size of flaw in LSI pakcage using the experimental result through flaw model.

PD Characteristic of Electrical Tree Generated by Inside Void Defect (내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성)

  • Park, Seong-Hee;Jung, Hae-Eun;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Non-Fourier 열전달에 대한 소고

  • 김우승
    • Journal of the KSME
    • /
    • v.31 no.8
    • /
    • pp.735-744
    • /
    • 1991
  • 확산모델과 파모델의 결과에 있어 큰 차이가 일어나는 경우를 요약하면 다음과 같다. 1) 과도기 간이 짧다. 2) 작동온도가 아주 낮다. 3) 온도구배가 상당히 크다. 이때3)의 경우는 서로 다른 물질들이 접촉된 경우 또는 높은 열유속이 있는 경우 또는 얇은 표면층 등을 갖는 문제들의 공 통적인 특징이다. Non-Fourier 열전도 문제를 이용해 온도 분포를 예측해야 하는 실제적인 몇 가지 예를 살펴 보면 레이저 기술 또는 절대온도 영(zero)에 접근하는 온도에서의 액체 헬륨을 다루는 저온공학연구 또는 1/$10^{6}$Inch 정도의 표면조도가 관심사인 정밀공학 등을 들 수 있다. 또한 상당히 높은 강도의 열원이 작용될 때 고체에서의 크랙이나 보이드(void) 같은 국소 결함은 확산거동이 나타나기에 요구되는 시간보다 짧은 시간 구간에서 발생되어질 수 있으며, 크랙발생의 방향과 같은 것들은 hyperbolic 모델에의해 예측되어져야만 한다. 특히 움직이는 열원 또는 propagating crack tip을 갖는 경우에 그들 주위에서의 온도장을 규정짓는 가장 중요한 변 수는 열마하수 M이며, 아음속에서 초음속 영역으로 천이될 때 물리적 양들의 변화에 있어서 일어나는 현상들은 열충격의 형성에 기인하는데 이러한 현상들은 확산 모델로서는 예측될 수 없는 특징들이다. 이상에서 살펴볼 때 non-Fourier 모델에 대해 관심을 기울일 필요가 있다고 사료된다.

  • PDF

Genetically Optimized Design of Fuzzy Neural Networks for Partial Discharge Pattern Recognition (부분방전 패턴인식을 위한 퍼지뉴럴네트워크의 유전자적 최적 설계)

  • Park, Keon-Jun;Kim, Hyun-Ki;Oh, Sung-Kwun;Choi, Won;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1891-1892
    • /
    • 2008
  • 본 논문에서는 부분방전 패턴인식을 위한 퍼지뉴럴네크워크(Fuzzy-Nueral Network를 설계한다. 퍼지뉴럴네트워크의 구조에서 규칙의 전반부는 개별적인 입력 공간을 분할하여 표현하고, 규칙의 후반부는 다항식으로서 표현되며 오류역전파 알고리즘을 이용하여 연결가중치인 후반부 다항식의 계수를 학습한다. 또한, 유전자 알고리즘을 이용하여 각 입력에 대한 전반부 멤버쉽함수의 정점과 학습률 및 모멤텀 계수를 최적으로 동조한다. 제안된 네트워크는 부분방전 패턴인식을 위해 다중 출력을 가지며, 초고압 XLPE 케이블 절연접속함의 모의결함에 대해 부분방전 신호를 패턴인식한다. 부분방전 신호는 PRPDA 방법을 통해 256개의 입력 벡터와 4개의 출력 벡터를 가지며, 보이드 방전, 코로나 방전, 표면 방전, 노이즈의 4개 클래스를 분류하며, 패턴인식률로서 결과를 분석한다.

  • PDF

Design of Fuzzy Set-based Fuzzy Neural Networks for Partial Discharge Pattern Recognition (부분방전 패턴인식을 위한 퍼지 집합 기반 퍼지뉴럴네트워크 설계)

  • Park, Keon-Jun;Oh, Sung-Kwun;Kim, Hyun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.453-454
    • /
    • 2007
  • 전력설비에 대한 부분방전 패턴인식은 결함의 차이에 따라 다양한 패턴의 차이를 보이고 있으며, 신경회로망을 비롯한 다양한 패턴인식 기법들이 적용되고 있다. 본 논문에서는 이의 일환으로 퍼지 집합 기반 퍼지뉴럴네트워크를 설계하여 초고압 XLPE 케이블 절연접속함의 모의 결합에 대해 부분방전 신호를 패턴인식하고자 한다. 부분방전 신호는 보이드 방전, 코로나 방전, 노이즈의 3개 클래스로 분류하게 되며, PRPDA 방법을 통해 556개의 입력 벡터와 3개의 출력 벡터를 가지며 총 120개의 패턴수를 가진다.

  • PDF