• Title/Summary/Keyword: 보수부

Search Result 651, Processing Time 0.025 seconds

Structural Design and Thermal Analysis of a Module Coil for a 750 kW-Class High Temperature Superconducting Generator for Wind Turbine (풍력 터빈용 750 kW 급 고온초전도 발전기 모듈의 코일 구조 설계 및 열 해석)

  • Tuvdensuren, Oyunjargal;Go, Byeong-Soo;Sung, Hae-Jin;Park, Min-Won
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2019
  • Many companies have tried to develop wind power generators with a larger capacity, smaller size and lighter weight. High temperature superconducting (HTS) generators are more suitable for wind power systems because they can reduce volume and weight compared with conventional generators. However, the HTS generator has problems such as huge vacuum vessel and the difficulty of repairing the HTS field coils. These problems can be overcome through the modularization of the HTS field coil. The HTS module coil require a current leads (CLs) for deliver DC current, which causes a large heat transfer load. Therefore, CLs should be designed optimally for reducing the conduction and Joule heat loads. This paper deals with a structural design and thermal analysis of a module coil for a 750 kW-class HTS generator. The conduction and radiation heat loads of the module coils were analysed using a 3D finite element method program. As a result, the total thermal load was less than the cooling capacity of the cryo-cooler. The design results can be effectively utilized to develop a superconducting generator for wind power generation systems.

A Study of Hydraulic Characteristics in Front of the Seawall under the Coexistence of Wave and Wind (파랑과 바람 공존장에서의 호안 전면 수리특성 검토)

  • Shim, Kyu-Tae;Kim, Kyu-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.575-586
    • /
    • 2020
  • In this study, a two-dimensional hydraulic model test was conducted to examine the hydraulic phenomena that occur around the seawall when wave and wind coexist. Based on recent seawall repair and reinforcement examples, the experimental section was constructed under the condition of installing wave dissipation blocks on the safety surface of four different representative seawalls. Water level fluctuation, reflection, overtopping and wave pressure characteristics according to external force change were reviewed. It was confirmed that the top concrete shape of the seawall is the most important factor of the hydraulic characteristics that appear in front of the seawall, and the tendency is more pronounced when wind acts. Even in the case of vertical type seawall, when wind of 3 m/s~5 m/s occurs, the amount of overtopping increases to about 5%~12%. In the case of wave pressure, it was confirmed from the experimental results that the value increased from about 1.5 to 2.2 times in front of the top of concrete block. In addition, it was confirmed that when the shape of the seawall was different, the range of change in the hydraulic characteristics appeared larger. Therefore, when designing a seawall of a new shape, a more detailed review of the hydraulic characteristics should be accompanied based on these experimental results.

The Harmony and Moderation of Between Defect Liability and Default Liability in the Construction Contract (도급계약에서 하자담보책임과 채무불이행책임의 조화와 중용 - 대법원 2020.6.11. 선고 2020다201156판결에 대한 고찰 -)

  • Ahn, Sanghyo;Sin, Manjoong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.2
    • /
    • pp.65-75
    • /
    • 2022
  • On 11 June 2021, the Supreme Court ruled that the judgment of the lower court was justified for the subject case, that the plaintiff could assert the defendant's liability for default due to incomplete performance even though the warranty period for defects which stipulated in the particular condition of the contract has expired. In Korean civil law, the concurrent between the exclusion period for defect warranty and the extinctive prescription for default liability is conceded, since the exclusion period and the extinctive prescription have their respective purposes in law, therefore these two should be judged by harmonizing them based on that they are mutually related. If the subject judgment is generalized, there is no reason to exist for the provisions of defect liability in the construction contract any longer. This study examines the subject judgments through the general theory and precedent case studies on the defect liability and default liability, then derived any problems that may arise if the subject judgment is generalized. In addition, based on a realistic model, it was suggested for a practical improvement method that both the provisions of the warranty period shall be changed realistic and to stipulate the character of its nature as written provisions in the contract.

Effects of Empowerment of Social Service Workers on Service Orientation: Focusing on the Mediating Effect of Job-esteem Attitude (사회서비스 종사자의 임파워먼트가 서비스지향성에 미치는 영향: 직업존중감의 매개효과를 중심으로)

  • Na, Yunjoung;Hwang, Hyewon
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.544-560
    • /
    • 2022
  • In order to verify the effect of job-esteem attitude on the empowerment of social service workers on service orientation, this study conducted a questionnaire survey on manpower providing local autonomous social service investment projects in Chungcheongbuk-do through analyzing 329 copies of data. The main research results show that, work performance relationship and personal work orientation have a significant effect on job esteem among the sub-factors of empowerment, it was found that the work environment control had a significant effect on all of the service-oriented sub-factors (trust-oriented, sincerity-oriented, and type-oriented). In addition, personal work-oriented empowerment was found to have a significant effect on sincerity-oriented and type-oriented among the service-oriented sub-factors, and it was confirmed that the empowerment of social service workers had a positive effect on service orientation through employee appreciation as a medium. It was confirmed that job-esteem, which is a mediator, affects sincerity and type orientation, which are sub-variables of service orientation. In order to improve the service orientation of social service workers, it is necessary to develop a manual for a clear understanding of their work and to provide continuous and practical maintenance education so workers can develop their own abilities.

Evaluation of Structural Performance of RC Beam with Different Depths to Lap Splice Detail of SD700 Headed Bar (SD700 확대머리 철근의 겹침이음 상세를 적용한 단차가 있는 RC 보의 구조성능 평가)

  • Lee, Ji-Hyeong;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.262-269
    • /
    • 2021
  • This paper conducts an evaluation of the structural performance of the lap splice detail of SD700 headed bar experiment for developing an RC beam with different depths joint details. The experiment variable is lap splice length, yield strength, and end anchorage of main reinforcements. For all specimens, a headed bar was applied to the main reinforcement of the beam with low depth (B2), and the beam with high depth (B1) was applied to the main reinforcement with two splice methods: straight headed bar and 90° hooked-headed bar. The experimental results were that specimens of applying SD500 and SD600 had the results of flexural fracture at the lap splice location, which maximum load was similar. For specimens of appling SD500, the 90° hooked-headed bar of B1, suppressed horizontal cracks in the lap splice section compared to the straight headed bar. Specimens of applying an SD 700 headed bar had the results of brittle anchorage failure. In addition, maximum load was increased with the lap splice length increasing. For specimens of applying SD700 headed bar, test for test maximum load/theoretical load for test development length/design development length were estimated to be 1.30~1.48 for the ACI 318-19 equation, and 1.14~1.30 for the KDS-2021 equation. Thus, ACI 318-19 equation had conservatively greater safety factors as estimated development lengththened.

A Study on Ethical Values and Professionalism of Dental Hygienists (치과위생사의 윤리적 가치관과 전문 직업성에 대한 인식 조사 연구)

  • Jung, Jung-Hwa;Kim, Min-A;Kim, Hyo-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.2
    • /
    • pp.357-364
    • /
    • 2022
  • This study conducted a survey of 265 dental hygienists working in Seoul and Gyeonggi Province from January 10 to February 28, 2021 to understand the ethical values and professional occupational characteristics of clinical dental hygienists. The difference in ethical values and professional occupational perception between subjects was post-tested using SPSS WIN 20.0 program and Scheffe test using independent sample T-test and one-way ANOVA. According to the results of the study, ethical thinking in ethical values was statistically significant in dental hospitals with higher final education, more work experience, and ethical work experience (p<0.05). The higher the age, the higher the final education, the more ethical education experience at university, the higher the sense of mission, the fewer working days, the more satisfying the job, the higher the organizational compliance with professional organizations and public service (p<0.05). The results of this study confirm the necessity of regular ethics education such as continuing education for dental hygienists, and are expected to be used as basic data to maintain ethical values and professionalism in clinical practice.

Study on Material Characteristic of Daegu Modern History Museum Collection Rickshaw (대구근대역사관 소장 인력거 재질분석 연구)

  • Lee, Ui Cheon;Lee, Yeong Ju;Kim, Soo Chul
    • Journal of Conservation Science
    • /
    • v.38 no.2
    • /
    • pp.133-143
    • /
    • 2022
  • In this study, we analyzed the rickshaw (Owned by the Daegu Modern History Museum) by measuring each material. The purpose of the study was to identify the materials in modern cultural assets that utilize a variety of materials in a complex way, and establish basic data for preservation and management. Using portable X-ray fluorescence analyzers (P-XRF), species identification, fiber identification, paint film analysis (microscope observation, SEM-EDS, FTIR) on metal, wood, fiber and paint was carried out. Brass, an alloy of Copper, Zinc and Iron, was measured in the metal parts. Further, wooden parts, such as Oak (Quercus acutissima), Japanese Cedar (Cryptomeria japonica), Bamboo (Bambusoideae). Torreya nucifera (Torreya spp.) were identified in the body. Fiber parts consisted mainly of cotton, but some parts were also made of leather. In terms of paint, rickshaws were applied with multiple layers, using cashew (synthetic paint used in place of lacquer). In sum, the rickshaw body part appeared to overlap with layers of fiber, metal (soild), paint, and colored (black, red) layer.

Evaluation of significant pollutant sources affecting water quality of the Geum River using principal component analysis (주성분분석(PCA) 방법을 이용한 금강 수질의 주요 오염원 영향 평가)

  • Legesse, Natnael Shiferaw;Kim, Jaeyoung;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.577-588
    • /
    • 2022
  • This study aims to identify the limiting nutrient for algal growth in the Geum River and the significant pollutant sources from the tributaries affecting the water quality and to provide a management alternative for an improvement of water quality. An eight-year of daily data (2013~2020) were collected from the Water Environment Information System (water.nier.go.kr) and Water Resources Management Information System (wamis.go.kr). 14 water quality variables were analyzed at five water quality monitoring stations in the Geum River (WQ1-WQ5). In the Geum River, the water quality variables, especially Chl-a vary greatly in downstream of the river. In the open weir gate operation, TP (total phosphorus) and water temperature greatly influence the growth of algae in downstream of the river. A correlation analysis was used to identify the relationship between variables and investigate the factor affecting algal growth in the Geum River. At the downstream station (WQ5), TP and Temp have shown a strong correlation with Chl-a, indicating they significantly influence the algal bloom. The principal component analysis (PCA) was applied to identify and prioritize the major pollutant sources of the two major tributaries of the river, Gab-cheon and Miho-cheon. PCA identifies three major pollutant sources for Gab-cheon and Miho-cheon, respectively. For Gab-cheon, wastewater treatment plant, urban, and agricultural pollutions pollution are identified as significant pollutant sources. For Miho-cheon, agricultural, urban, and forest land are identified as major pollutant sources. PCA seems to be effective in identifying water pollutant sources for the Geum River and its tributaries in detail and thus can be used to develop water quality management strategies.

Performance evaluation of hyperspectral image for morphological mapping (초분광 영상을 활용한 하상 측정 성능 평가 )

  • Youngcheol Seo;Dongsu Kim;Hojun You;Yeonghwa Gwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.225-225
    • /
    • 2023
  • 하상 측정은 하천 유지관리, 수공구조물 설계 및 보수, 수생태 조사의 필수적인 자료이다. 최근 4대강 대규모 사업 이후 자연적 안정화로 인해 침식 및 재퇴적이 진행되어 정밀 하상 모니터링이 요구되고 있다. 통상적인 하상 조사 기법은 레벨측량 및 RTK-GPS 등을 활용하여 점단위로 직접 계측하는 기법과 수심이 깊을 경우 ADCP와 같은 음향측심기법을 통해 하상변동을 계측하고 있다. 하지만 점단위 직접 측정은 사구와 사련과 같은 하상 구조 교란 및 계측 시 위험을 동반하고 수심자료의 측정오차가 크게 발생하는 한계점이 존재한다. 또한 초음파 방식의 경우 막음길이와 바닥면 노이즈 등의 한계점으로 50 cm 미만의 저수심부 하상 측정이 불가능한 실정이다. 이러한 한계점을 극복하기 위해 최근 드론의 보급으로 수심라이다(Bathymetry LiDAR), SFM, 드론 탑재 초분광 영상을 활용한 초분광수심법과 같은 저고도, 고해상도의 비접촉식 면단위 하상 측정 기법이 대안으로 각광받고 있고 최근 관심은 해당 최신 기술의 성능 점검 및 적용성 평가에 있다. 따라서 본 연구에서는 초분광수심법 중 보편적으로 적용할 수 있는 최적밴드비분석(OBRA)의 성능 점검과 실무 적용성을 국내 하천을 대상으로 검토하였다. 해당 기술의 실무 적용성 평가항목 중 수심 적용 범위가 경제적이고 효율적인 성능 평가의 주된 항목이다. 선행 연구에 따르면 감천을 대상으로 저수심부의 성능 평가를 진행한 결과 상세한 하상계측이 가능하다고 제시하였다. 따라서 본 연구는 낙동강-황강 합류부를 대상으로 전형적인 평수기 탁도 조건에서 초분광수심법을 적용할 경우 최대측정가능수심의 범위를 결정하는 방법 및 결과를 제시하려고 한다. 또한 현장실험 당시 합천댐 방류로 인하여 황강의 탁도가 높아진 상태에 기인하여 고탁도 조건에서 초분광수심법의 적용성 평가도 추가 검토하였다. 해당 연구는 수심과 밴드비의 비선형성을 통해 최적 밴드비 분석의 결과로 도출될 수 있는 상관계수와 평균 제곱근 오차(RMSE)의 동향을 보아 다양한 시나리오의 배제수심을 통해 최대측정가능수심을 산정하였으며 그 이상의 범위는 수심맵 산정에서 제외하였다. 그 결과로 낙동강 본류에서 2.5 m 이하, 황강 지류에서 1.25 m 이하의 최대측정가능수심이 나타났고 해당 범위 이하에서는 상세한 하상이 나타났다. 또한 고탁도 조건인 황강에서는 낙동강에 비해 절반 수준의 최대측정가능수심 범위가 나타나 탁도 조건에 따른 초분광수심법의 한계가 있는 것을 확인하였다.

  • PDF

Evaluation of low-vibration electronic detonator blasting method to improve constructability in non-vibration excavation section (무진동 굴착구간에서의 시공성 향상을 위한 미진동 전자발파공법 평가)

  • Seung-won Jung;Jin-Hyuk Song;Nam-Sun Hwang;Hyun-Gi Kim;Nam-Soo Kim;Jong-woo Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.157-173
    • /
    • 2023
  • Although this site is designed with a non-vibration excavation method for a section of 265 m, there are concerns about decline of constructability and economic feasibility. For this reason, the low-vibration electronic detonator blasting method was suggested. To evaluate the applicability of the low-vibration electronic detonator blasting method, the damage range of blasting vibration of low-vibration electronic detonator blasting applied just before the site (suggestion I) and low-vibration electronic detonator blasting constructed close range the subway like this site (suggestion II) was analyzed. As a result of comparing the blasting vibration damage ranges of the two suggestions, the damage range of suggestion II was calculated more conservatively. Considering the specificity of the close range of this site, suggestion II was selected for design change for safer construction. As a result, it is predicted that there will be no damage to the structure even if the 72 m section out of the non-vibration excavation 265 m section is changed to the Low-vibration electronic detonator blasting. And it is evaluated that high economic benefits can be obtained because the total expected excavation period can be reduced by 144 days from 662.5 days.