공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.

계층적 블록매칭 알고리즘을 위한 파이프라인식 VLSI 아키텍쳐 (Pipelined VLSI Architectures for the Hierarchical Block-Matching Algorithm)

  • 김형철;맹승렬
    • 한국정보처리학회논문지
    • /
    • 제5권7호
    • /
    • pp.1691-1716
    • /
    • 1998
  • 본 논문에서는 계층적 블록매칭 알고리즘(HBMA)을 위한 두 가지 병렬 VLSI 아키텍쳐를 제안한다. HBMA는 계층에 따른 반복수행과 공간 인터폴레이션을 기반으로 수행되며, 이러한 수행 특성은 병렬처리의 장애요소인 데이터 종속성을 내재하고 있다. 제안된 아키텍쳐는 HBMA의 계층간 데이터 종속성을 해결하기 위하여 기본적으로 파이프라인 구조를 채택하고 있으며, HBMA에서 주어진 매개변수에 따라 세 단계의 스테이지로 구성된다. 제안된 아키텍쳐는 입력 프레임 데이터의 흐름을 제어하는 방식에 따라 두 가지 종류로 구분된다. U-Architecture는 단방향 스캔 순서를 따르도록 설계되었으며, B-Architecture는 양방향 스캔 수서를 따르도록 설계되었다. 각 아키텍쳐의 내부 메모리와 인터폴레이션 모듈은 해당 스캔 순서에 따라 동기적으로 동작할 수 있는 구조를 가진다. 성능분석의 결과로서 본 논문에서 제안한 두 가지 아키텍쳐가 모두 방송용 비디오 포맷을 실시간으로 처리할 수 있음을 보이고, HDTV 포맷은 가까운 장래의 VLSI 기술로 실시간 성능을 얻을 수 있음을 보였다. 또한, B-Architecture는 공간 연결성 내부 메모리 구조를 채택함으로써 입력 데이터의 재활용도를 높이고, 이에 따라 Q-Architecture에 비해서 데이터 입출력 핀의 개수를 약 반정도 줄일 수 있는 특성을 보이고 있다.

  • PDF

하둡 맵리듀스와 페이지 랭크를 이용한 서울시 대중 교통 인구 이동 분석 (Analysis of the population flow of public transportation in Seoul using Hadoop MapReduce and PageRank algorithm)

  • 백민석;오상윤
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2022년도 추계학술발표대회
    • /
    • pp.354-356
    • /
    • 2022
  • 소셜 네트워크 및 웹 데이터와 같은 대규모 그래프 데이터를 처리하기 위해 병렬 처리 기반의 기법들이 많이 사용되어 왔다. 본 연구에서는 그래프 형식의 대규모 교통 데이터를 하둡 맵리듀스를 이용하여 처리하는 효과적인 기법을 제안한다. 제안하는 방식에서는 도시의 유동 인구 흐름을 가중치로 고려할 수 있도록 Weighted PageRank 알고리즘을 기반으로 하는 병렬 그래프 알고리즘을 사용하며, 해당 알고리즘을 하둡 맵리듀스에 적용하여 주거 및 근무지 등의 지역을 분류하도록 결과를 분석하였다. 제안 기법을 통한 분석 결과를 기반으로 지역 간 유동 인구 그래프 데이터에서 각 도시의 영향력을 측정하는 페이지랭크, 하둡 맵리듀스 기반의 기법을 제시한다.

가상화 방식에 따른 하이퍼바이저의 비교 분석 (The comparative analysis of Hypervisor according to Virtualization Method)

  • 정영교;이병준;윤희용
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2015년도 제51차 동계학술대회논문집 23권1호
    • /
    • pp.251-253
    • /
    • 2015
  • 가상화는 다양한 IT분야에서 빠르게 발전하고 기술의 사용이 급격히 증가함에 따라 오픈소스 커뮤니티(Xen, KVM 등)와 기업(Citrix, VMware, Microsoft 등)을 중심으로 다양한 종류의 하이퍼바이저가 개발되었다. 가상화 기술이 발달하면서 서버, 네트워크, 스토리지 통합이 더욱 활발해졌고, 가상화 기술과 병렬 처리 기술이 결합되면서 클라우드 컴퓨팅(Cloud Computing)이라는 거대한 흐름이 생겨났다. 각각의 하이퍼바이저는 가상화라는 동일한 목적을 가지고 이를 다른 방식으로 구현되었으며, 나아가 가상화 기술의 성능 향상을 위해 하나의 하이퍼바이저 내에서도 여러 방식의 가상화 모드를 지원할 수 있게 되었다. 본 논문에서는 하이퍼바이저 중 Xen과 KVM에 대하여 비교 분석 하였다.

  • PDF

객체지향 프로그램 정보 분석기 설계 및 구현 (Design and Implementation of an Information Analyzer for Object-Oriented Program)

  • 김운용;최영근
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 1999년도 가을 학술발표논문집 Vol.26 No.2 (1)
    • /
    • pp.490-492
    • /
    • 1999
  • 본 논문에서는 객체지향 프로그램에 대한 프로그램 정보를 분석하여 이들간의 관계를 표현할 수 있는 방법을 제시한다. 현재까지 프로그램을 분석하고 표현하기 위한 그래프 표현으로 호출 그래프, 제어흐름 그래프 및 종속 그래프 등이 있으며 이를 이용하여 테스팅, 슬라이싱, 디버깅, 프로그램 이해, 병렬처리, 역공학과 같은 다양한 분야에 적용되고 있다. 본 논문에서는 객체지향 언어의 프로그램의 시각적 이해를 돕고, 분석에 필요한 정보를 표현하는 그래프들간의 관계성을 고려한 효율적인 분석기를 표현한다. 이를 위해 클래스, 상속관계, 호출관계, 제어흐름 및 데이터 종속관계를 고려하여 객체 지향언어 분석에 필요한 그래프 요소를 멤버함수레벨, 클래스 레벨, 모듈 클래스 레벨 단위로 추출하고 이들간의 정보를 저장소로 통합 구성한다. 이를 통해 기존의 특정목적을 위해 표현하는 그래프 표현 방식은 그래프간의 관계성과 분석정보의 독립성 그리고 재사용성의 특징을 가지는 통합 분석기로 구성될 수 있다. 이러한 특징은 프로그램의 이해와 정보의 관리효과를 증가시킬 수 있으며, 많은 소프트웨어 엔지니어링 도구와 기술들에 필요한 통합화된 정보를 제공하고 이용될 수 있을 것이다.

  • PDF

흡수식 냉동기에서 흡수액이 증발기로 혼입시 냉각용량과 성능계수에 미치는 영향 (The Influences of the Refrigerant Adulteration by an Absorbent on the Cooling Capacity and COP of the Absorption Chiller)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.753-760
    • /
    • 2006
  • The purpose of the present work is to investigate the influence of the refrigerant adulteration by LiBr solution on the cooling capacity and COP for three different types of abso게tion chillers: a single-effect type, a series-flow double-effect type and a parallel-flow with double-effect type. A simulation program has been prepared for the cyclic analysis of absorption chillers. With some assumptions, the calculations have been performed by solving the mass balance equation, energy balance equation and the state equation simultaneously. The range of the LiBr concentration of refrigerant was 0% to 20% in the present study. For the single-effect absorption chiller, the maximum decrease in the cooling capacity was 10% at the 20% of LiBr concentration. For the double-effect chiller, the capacity was decreased by 11.1% for the parallel-flow type and the series-flow type. Also, the COP was reduced by 3.0% in single-effect, 2.8% in series-flow type (SR=0.4) and 2.3% in parallel-flow type.

IS-95 진화방안에서 고속 데이터 전송을 위한 M/B-MC/CDMA 전송방식의 성능분석 (M/B-MC/CDMA performance analysis for high speed data transmission in IS-95 evolution)

  • 임명섭
    • 한국통신학회논문지
    • /
    • 제24권10A호
    • /
    • pp.1494-1500
    • /
    • 1999
  • 다양한 데이터 전송속도가 혼합된 고속의 멀티미디어 서비스를 제공하기 위해 Multi-Code CDMA (Code Division Multiple Access) 전송 방식이 제안되고 있다. 이 전송방식은 고속의 데이터를 N개의 병렬 저속 데이터 흐름으로 바꾸고, 서로 구별 가능한 PN코드로 확산 후 합하여 발생하는 multi level 신호를 전송한다. 이 multi-level신호는 역방향 link상에서 이동국 송신 출력이 커짐에 따라 인접 서비스 구역에 미치는 간섭양이 증대되는 문제점이 발생한다. 따라서 이러한 문제점을 해결할 수 있는 M/B 변환부(multi level to binary level conversion)를 이용하여 multi level의 신호를 binary level 신호로 바꾸어 전송하는 Multi-Code CDMA 전송방식을 제안하고, M/B를 사용한 MC-CDMA 전송방식과 M/B를 사용하지 않은 MC/CDMA 전송방식의 성능을 비교하였다.

  • PDF

분포형 강우유출모형(K-DRUM)의 병렬화 효과 분석 (The Parallelization Effectiveness Analysis of K-DRUM Model)

  • 정성영;박진혁;허영택;정관수
    • 대한공간정보학회지
    • /
    • 제18권4호
    • /
    • pp.21-30
    • /
    • 2010
  • 본 연구에서는 기존에 개발된 GIS 기반의 분포형 강우유출모형(K-DRUM)이 대유역에서 많은 계산시간을 요구하는 단점이 있기 때문에 이를 개선하기 위하여 MPI(Message Passing Interface)기법을 적용한 병렬 K-DRUM모형을 개발하였다. K-DRUM 모형은 홍수기동안의 지표흐름과 지표하 흐름의 시간적 변화와 공간적 분포를 모의할 수 있으며, 전처리과정으로서 ArcView를 이용하여 모형에 필요한 ASCII형태의 입력 매개변수 자료들을 가공하였다. 개발된 병렬 K-DRUM 모형을 이용하여 남강댐유역에서 2006년 태풍 '에위니아' 사상을 대상으로 다양한 영역분할을 통한 유출계산 검토를 하였다. 영역분할 개수에 따른 병렬화 효과를 검토하기 위하여 분할 개수를 1개에서 25개까지 증가시키며 클러스터 시스템에서 유출모의를 수행하였다. 모의결과 영역분할 개수가 증가할수록 컴퓨터 메모리의 개수가 감소하게 되고, 이에 따라 모의수행시간 역시 감소함을 알 수 있었다. 또한 본 연구에서 영역분할 계산방식을 채택함에 따라 영역의 접합부분에서 발생 가능한 유출량 계산오차를 최소화하기 위한 기법을 제시하였다. 유출량 계산오차 발생을 최소화하기 위해서는 단위 계산시간당 영역간 정보교환과 내부유출량 계산을 최소3회 반복하여야 함을 알 수 있었다.

멀티코어 시스템에서 흐름 수준 병렬처리에 기반한 리눅스 TCP/IP 스택의 성능 개선 (A Performance Improvement of Linux TCP/IP Stack based on Flow-Level Parallelism in a Multi-Core System)

  • 권희웅;정형진;곽후근;김영종;정규식
    • 정보처리학회논문지A
    • /
    • 제16A권2호
    • /
    • pp.113-124
    • /
    • 2009
  • 최근 멀티코어가 장착된 시스템이 증가하면서 이를 통한 애플리케이션 성능향상에 대한 노력이 계속 되어왔다. 하나의 시스템에 다수의 처리장치가 존재함으로 인해 프로세싱 파워는 기존보다 증가했지만 기존의 소프트웨어나 하드웨어들은 싱글코어 시스템에 적합하게 설계된 경우가 많아 멀티코어의 이점을 충분히 활용하지 못하고 있는 경우가 많다. 기존의 많은 소프트웨어들은 멀티코어 상에서 공유 자원에 대한 병목현상과 비효율적인 캐시 메모리 사용으로 인하여 충분한 성능향상을 기대하기 어려우며 이러한 문제점들로 인하여 기존 소프트웨어는 코어의 개수에 비례한 성능을 얻지 못하며, 최악의 경우 오히려 감소될 수 있다. 본 논문에서는 TCP/IP를 사용하는 기존의 네트워크 애플리케이션과 운영체제에 흐름 수준 병렬처리 기법을 적용하여 성능을 증가 시킬 수 있는 방법을 제안한다. 제안된 방식은 개별 코어단위로 네트워크 애플리케이션, 운영체제의 TCP/IP 스택, 디바이스 드라이버, 네트워크 인터페이스가 서로 간섭 없이 작동할 수 있는 환경을 구성하며, L2 스위치를 통해 각 코어 단위로 트래픽을 분산하는 방법을 적용하였다. 이를 통해 각 코어 간에 애플리케이션의 데이터 및 자료구조, 소켓, 디바이스 드라이버, 네트워크 인터페이스의 공유를 최소화하여, 각 코어간의 자원을 차지하기 위한 경쟁을 최소화하고 캐시 히트율을 증가시킨다. 이를 통하여 8개의 멀티코어를 사용하였을 경우 네트워크 접속속도와 대역폭이 코어의 개수에 따라 선형적으로 증가함을 실험을 통해 입증하였다.

H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH)

  • 권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.