• Title/Summary/Keyword: 병렬저항

Search Result 192, Processing Time 0.031 seconds

Analysis of Negative Resistance Maximum Oscillating Frequeney (부저항발진기의 최대주파수 해석(I보))

  • 김영권;서정홍
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.2
    • /
    • pp.6-20
    • /
    • 1969
  • Tunnel diode oscillator consisting of a tunnel diode(negative-resistance element) and a passive linear load. In this paper maximizing the frequeney of a negative reistance oscillator with varying a passive linear load is investigated. The method of theoretical analysis, utiliying impedance loei in the complex plane and experimental data shows that the maximum frequencies of quasi-harmonic oscillation is higher in the parrallal-RL load than in the resistive load.

  • PDF

A.C.impedance properties on $RuO_2$-based thick film resistors ($RuO_2$계 후막저항체의 교류 임피던스 특성)

  • 구본급;김호기
    • Electrical & Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.315-324
    • /
    • 1990
  • 저저항(DuPont 1721, 100.OMEGA./sq.)과 고저항(1741, 10K.OMEGA./sq.)의 두 Ru계 후막저항체를 여러 조건에서 소결하여 소결막의 복소임피던스 특성과 임피던스의 주파수의존성을 1KHz-13MHz의 주파수 범위에서 조사하였다. 저저항 1721계의 경우 600.deg.C이상에서 소결한 모든 시편이 거의 저항성분(R)만으로 구성된 등가회로에 해당되는 복소임피던스 거동을 보였으며 임피던스에 미치는 주파수 의존성은 크게 나타나지 않았는데 5KHz까지는 주파수에 따라 변화가 없다가 그 이상의 주파수에서 주파수 증가에 따라 약간씩 증가하였다. 고저항 1741 후막저항체의 경우는 소결조건에 따라 복소임피던스 거동과 임피던스에 미치는 주파수 의존성이 달리 나타났다. 600.deg.C에서는 용량(C) 성분만으로 구성된 등가회로에 해당하는 복소임피던스 거동을 얻었고 주파수 증가에 따라 임피던스가 직선적으로 감소하였으며 700.deg.C이상 900.deg.C까지는 저항(R)과 용량(C)이 병렬로 연결되는 형태의 등가회로에 해당하는 복소임피던스 거동을 얻었고 이때의 임피던스의 주파수 의존성은 저주파수 영역에서는 임피던스가 주파수에 변함없이 일정하다가 5KHz이상의 주파수에서는 주파수 증가에 따라 임피던스가 직선적으로 감소하였다. 1000.deg.C반응에서의 복소임피던스 거동은 RCL성분이 병렬로 연결된 형태의 등가회로에 해당되는 결과를 얻었으며 임피던스도 작아지고 주차수 의존성도 현저하지 않았다.

  • PDF

A Study on the Protection Circuit Of the Inverter For Back-Light a Large-screen (대화면 LCD 백라이트 구동용 인버터 보호회로에 대한 연구)

  • Lee Jeong-Woon;Yang Seung-Hak;Lim Young-Cheol;Cho Hyun-Chang
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.516-519
    • /
    • 2006
  • LCD TV의 대형화 추세에 따라 백라이트 구동용 인버터의 가격을 낮추고 휘도의 균일성을 보장하기 위해 다수개의 CCFL을 병렬로 구동하는 방식을 채택하고 있다. 그러나 다수개의 CCFL 중에 어느 하나가 먼저 점등되면, 등가 병렬저항이 점등된 램프 하나의 저항으로 나타나게 된다. 이 경우, 점등되지 못한 나머지 CCFL은 전등을 위한 충분한 전압을 받지 못하게 되어 전등이 되지 않은 상태로 머물러 있게 되고, 각 CCFL간의 과전류 편차로 인한 휘도 불균형이 문제점으로 나타나고 있다. 본 논문에서는 LCD 백라이트 구동용 인버터에서 발생하는 전압 전류의 출력 블균형에 대해서 연구하였으며, 이를 바탕으로 OVP(Over Voltage Protection), LCC(Limited Current Circuit), OLP(Open Lamp Protection)의 기존 Analog IC의 보호회로를 통합하여 하나의 MCU로 구성하였다.

  • PDF

Interpretation of Electrical Resistivity Tomogram with Contents of Clay Minerals for the Land Creeping Area (점토광물 함유량을 고려한 땅밀림 산사태 지역의 전기비저항 자료의 해석)

  • Kim, Jeong-In;Kim, Ji-Soo;Lee, Sun-Joong;Cho, Kyoung-Seo;Kim, Jong-Woo
    • The Journal of Engineering Geology
    • /
    • v.31 no.2
    • /
    • pp.187-197
    • /
    • 2021
  • Clay mineral content of weathered zone is a key parameter for landslide studies. Electrical resistivity tomography is usually performed to delineate the geometry of complex landslides and to identify the sliding surface. In clay-bearing weathered zone, parallel resistivity Archie equation is employed to investigate the effect of conductivity added (resistivity reduced) by clay minerals of kaolinite and montmorillonite, which is dependent on their specific surface area and cation exchange capacities (CEC). A decrease of overall resistivity and apparent formation factor is observed with increasing pore-water resistivity, significantly in montmorillonite. Formation factor is found decreased with increasing porosity and decreasing cementation factor. Parallel Archie equation was applied to the electrical resistivity data from the test area (Sinjindo-ri, Taean-gun, Chungcheongnam-do, Korea) which experienced land creeping in the year of 2014. A panel test with varying clay-mineral contents provides the best fit section when the theoretical section constructed with the assumed contents approaches the field section, from which the clay-mineral content of the weathered zone is estimated to be approximately 10%. Resistivity interpretation schemes including the clay mineral contents for land creeping studies explored in this paper can be challenged more when porosity, saturation, and pore-water resistivity are provided and they are included in the numerical resistivity modeling.

A Wireless Parallel Operation of Single-phase UPS Inverter using Single-loop Robust Voltage Controller (단일 루프 강인 전압 제어기를 이용한 단상 UPS 인버터의 비통신선 방식 병렬 운전)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Gueesoo
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.203-204
    • /
    • 2011
  • 단일 루프 강인 전압 제어기를 이용한 단상 3kVA UPS 인버터의 비통신선 방식 병렬 운전 결과를 기술한다. 단상 UPS 인버터 2대로 병렬운전 실험 환경을 구축하였고, 주파수-전압 강하 방식의 수하 제어를 이용하여 저항 부하, 비선형 부하에 대한 전력분담을 실험을 통하여 확인하였다.

  • PDF

Heat Conduction Analysis of Metal Hybrid Die Adhesive Structure for High Power LED Package (고출력 LED 패키지의 열 전달 개선을 위한 금속-실리콘 병렬 접합 구조의 특성 분석)

  • Yim, Hae-Dong;Choi, Bong-Man;Lee, Dong-Jin;Lee, Seung-Gol;Park, Se-Geun;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.342-346
    • /
    • 2013
  • We present the thermal analysis result of die bonding for a high power LED package using a metal hybrid silicone adhesive structure. The simulation structure consists of an LED chip, silicone die adhesive, package substrate, silicone-phosphor encapsulation, Al PCB and a heat-sink. As a result, we demonstrate that the heat generated from the chip is easily dissipated through the metal structure. The thermal resistance of the metal hybrid structure was 1.662 K/W. And the thermal resistance of the total package was 5.91 K/W. This result is comparable to the thermal resistance of a eutectic bonded LED package.

Current sharing method for parallel bidirectional dc-dc converters using the switching frequency analysis (스위칭 주파수 분석을 이용한 병렬 양방향 DC-DC 컨버터의 전류분배 제어방법)

  • Chae, Suyong;Park, Jinju;Baek, Jongbok
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.85-86
    • /
    • 2016
  • 본 논문은 스위칭 주파수 스펙트럼 분석에 기반한 모듈형 병렬 양방향 DC-DC 컨버터의 전류분배 제어방법을 제안한다. 병렬 DC-DC 컨버터 각 모듈의 전류분배 균일도 향상은 동작안정성 확보, 효율 및 신뢰성 향상을 위해 매우 중요한 요소이다. 드룹 제어의 적용을 통해 별도의 통신연결 없이 각 병렬모듈간 전류 분배량 제어가 가능하지만, 선로 저항의 차이나 측정 소자의 편차가 발생할 경우 각 모듈간 균일한 전류분배가 어려운 문제가 존재한다. 각 모듈간 전류분배를 위해 각 개별모듈의 입력 전류에 존재하는 스위칭 주파수 성분만을 분석하여 병렬 모듈 사이의 전류분배 차이를 검출하고, 그 차이를 최소화 하도록 드룹 이득을 단계적으로 조절하는 제어 알고리즘을 제안한다. 제안된 제어 알고리즘은 에너지 저장장치와 연계된 380V급 DC 배전 시스템 모델을 대상으로 검증하였다.

  • PDF

The Parallel Driving Characteristics of Piezoelectric Transformer (압전 변압기의 병렬 구동 특성)

  • Lee, J.S.;Hong, J.K.;Chai, H.I.;Yoon, M.S.;Jeong, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1584-1586
    • /
    • 2000
  • 본 논문에서는 압전 변압기의 병렬 구동에 대해 연구하였다. 병렬 구동을 함으로서 단일 구동시에 대해 $\sqrt{2}$정도의 출력 전압을 얻었다. 적외선 온도계를 이용하여 압전 변압기의 온도 상승률을 측정한 결과 단일 구동시보다 병렬 구동에 진동 손실 에너지의 감소를 얻을 수 있어 온도 상승률을 억제할 수 있었다. 또한 병렬로 구동함으로서 압전 변압기의 출력 임피던스를 감소시키므로 단일 구동시보다 최대 효율을 나타내는 부하 저항이 감소하였고 100[$k\Omega$]에서 91[%]정도를 나타내었다.

  • PDF

Physical Property Factors Controlling the Electrical Resistivity of Subsurface (지반의 전기비저항을 좌우하는 물성요인)

  • Park Sam-Gyu
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.2
    • /
    • pp.130-135
    • /
    • 2004
  • This paper describes the physical properties of the factors controlling the electrical resistivity of the subsurface. Resistivities of various types of soil and rock samples saturated with sodium chloride solutions having nine different concentrations were measured, and the measured resistivities of these samples were compared with calculated resistivities obtained using the conventional empirical formulas. From the results obtained, we observed that the resistivity of the soil and rock samples increases with increasing in pore-fluids resistivity regardless of the media type. However, between 20 and 200 ohm-m, which is the normal range of resistivity of groundwater, the resistivity of the pore-fluids have little or no effect on the resistivities of the samples used. Below 10 ohm-m, the resistivities of the samples are mainly controlled by the pore-fluids, whereas, in the normal range of resistivity of groundwater, the sample resistivities are controlled by their intrinsic matrix resistivity more than by the pore-fluids resistivity. Also, the measured resistivity of rock and soil samples having more than $20\%$ clay contents showed a good agreement with the calculated resistivity using the parallel resistance model whereas, the calculated resistivities of glass beads correlate with that obtained using Archie's formula. When the pore-fluid resistivity is high, the computation of the resistivity values of the samples using the Archie's formula could not be carried out. Through this study, we were able to confirm that the tests are only applicable to the parallel resistance model considering the intrinsic matrix resistivity within the normal resistivity range of groundwater in the subsurface.