• Title/Summary/Keyword: 병동디자인

Search Result 27, Processing Time 0.019 seconds

An Architectural Study on the Healing Environment Design through the Analysis of Sensory Stimulation in the General Hospitals' Patient-Room (감각자극 분석을 통한 종합병원 다인 병실의 치유 환경에 관한 건축 계획적 연구)

  • Chung, Joo-Hyun;Yang, Nae-Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.7-15
    • /
    • 2006
  • Patients use the senses all the time, mostly simultaneously. Senses are never turned off even patients in serious condition use some of the senses. Space is the inexhaustible source of stimuli. So far we have thought that it is impossible to come up with a set of rules and guidelines that cover all the possible situations involving senses and when there have been usually no conscious coordination between different sensorial stimuli and the comprehensive perception of space always results from the engagement of combination of senses and other inputs based on knowledge and experience. This study concerns about patients' demand analysis through senses. The reflection of patients' demand to the ward planning can develope the healing environment.

  • PDF

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

Space planning about Personal Protective Equipment(PPE) Doffing Area to reduce cross-infection among healthcare workers (의료진 교차감염을 낮추기 위한 음압격리병동 내 개인보호구 탈의구역의 공간구성)

  • Park, Doeun;Lee, hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.37-44
    • /
    • 2023
  • Purpose: To decrease cross-infection, it's essential to analyze the spatial composition of the 'PPE doffing area'. Instead of solely relying on manpower standards, we should focus on responding to infectious diseases within the context of space planning. By doing so, we can lower the risk for healthcare workers' infection and ensure a level of safety in various environmental changes or new manpower input situations. Methods: This analysis is conducted specifically for facilities with negative pressure isolation wards. Additionally, interview surveys to obtain feedback from healthcare workers and incorporate their expertise into the design of the 'PPE doffing area' have been carried. Results: In a PPE doffing area, the standard spaces include a PPE doffing room, a shower room, and a clothing room. Depending on the facility environment or the level of infectious diseases, a Decontamination room or Anteroom can be optionally added. Healthcare workers who remove their PPE in the PPE doffing room should avoid re-entering the Negative pressure room. The shower room is often underutilized. When planning for a future PPE doffing area, an aisle space or passageway must be included even if a shower room is planned. Implications: This study examined the space used by healthcare workers rather than patients, with a focus on infection prevention through architectural planning rather than individual efforts. However, the investigation was limited to facilities that have been converted from general wards to negative pressure isolation wards, so it cannot be generalized to all infectious disease facilities.

A Study on the Change of Form Type in General Hospital (국내 종합병원의 형태 유형 변화에 관한 연구)

  • Kim, Eun-Seok;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.195-203
    • /
    • 2014
  • This study selects factors affecting form type of hospital architecture by considering studies and references on hospital architecture type in korea and other countries in general. Also this study classifies general hospitals chronologically and analyzes type change of general hospitals in relation with periodic change of healthcare environment. Through this, this study aims to analyze chronological change of general hospitals' form type and provide the current of hospital architecture's general type. The form type classification of this study is classification according to the form of ward, classification according to the relationship between ward and D.T.D(Diagnostic and Treatment department), classification according to the relationship between O.P.D(Out Patient department) and D.T.D, classification according to the rate of centralization, classification according to the circulation system. The form type of ward changed from plate type to tower type, and the circulation system of ward changed from middle corridor to double corridor, the number of Team Nursing chaged from 1 to 2 in 1990. On the other hand the chage of others classifications took place from 1990' to 2010'. It is judged that this overall change is appeared by a change from an inpatien-oriented system to an outpatient-oriented system followed by an increase in number of outpatients, an increase in amenities in ground floor and adoption of healing environment for patients and visitors.

Development of the Nurse Uniform to Improve Nursing Service - Focused on the Summer Uniform in the General Ward - (간호업무 능률향상을 위한 간호사복 개발 - 일반병동 하복을 중심으로 -)

  • Lee, Mi Kyung;Lee, Jeong Ran
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.6
    • /
    • pp.32-45
    • /
    • 2016
  • The purpose of this study is to propose changes that can be made to improve nurse uniforms in terms of outfit and functionality based on actual wearing conditions and nurse's preference. The proposed nurse uniform was composed of a blouse and pants. The design was as follows: the blouse had short set-in sleeve with China collar, a princess line, and it came down to middle hip. Armhole action pleats and back inverted pleats were embedded for convenient arm movements. The pants waist had a rubber band at the back waist, and the crotch length and the knee width were increased for activity. To make the pocket more accommodative, separate pocket slots treated with silicone were added to prevent belongings from coming out of the pocket. The pink tone of the uniforms, as well as the stripes on the blouses and spandex incorporated pants were based on nurses' preference. the nurse uniforms were produced after measuring the size of women in the age of 25 to 29, and the uniform patterns were corrected after two wearing experiments. Wearing test was examined in terms of appearance and functionality. For appearance, experts gave the uniforms a mean rating of 4.30, and nurses gave a mean rating of 4.00. Functionality was evaluated in terms of ease of activity and storage aspects. The total mean of ease of activity in nursing service was 4.30, whereas the evaluation of storage in terms of pocket position and convenience was 3.80.

Review of Research Literature on Interruptions and Performance for Hospital Design: Hospital and Office Comparison (병원 디자인을 위한 업무간섭에 관한 문헌조사 연구: 병원과 사무실의 비교)

  • Seo, Hyun-Bo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the role of the physical environment in task interruptions in the healthcare settings. Many dangerous events such as airplane crash and medical errors are the result of human errors and, these errors are often the result of interruptions during a critical task of professional workers. In fact, the physical environment that determines accessibility and visibility among people affects interruptions significantly, but architectural studies have given little attention to the management of interruptions. Methods: Therefore, the researcher reviewed research literature in other fields to find out how the physical environment affected interruptions. Many studies were from management, human factors, and health care, but few from architecture. First the author examined the impact of interruptions, second described the social context of interruptions and the role of the physical environment. Results: Findings included that description of the physical environment was not very clear in studies from management and human factors, while little work had been done on interruptions in architecture. The author proposed study design that compensated shortcomings of each field by combining approaches from management, human factors, and architecture. Implications: Unit design strategies such as distributed nurse stations can affect interruptions and layout analysis such as space syntax analysis can evaluate visibility and accessibility of floor plans in the preliminary design phase.

A Study on the Ward Module according to the External Design of the Hospital (병원 외주부 디자인에 따른 병실모듈 연구)

  • Lee, Hyunjin;Park, Wonbae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: It is important to plan the ward module at a time when the size of beds, the floor area, and the construction budget are all set prior to the hospital design. In this context this study aims (1) to derive various factors affecting the ward module, and (2) to analyze the appropriate room module according to the type. Methods: Design factors related to hospital modules are derived through precedential studies, and the types of ward elevation are classified by reviewing the drawings of 18 case hospitals. And the detailed dimensions and area of the derived elements are analyzed. Results: The X-axis modules of the ward are switched to long span structural columns of 9.9 m, 12.6 m and 13.2 m, but the ward modules still represent 6.6 m. The Y-axis module of the ward shows a dimension of 9 to 9.9m in the process of changing a multi-person room into a four-person room. Type A of curtain wall with columns located on the wall of the room and type B of curtain wall located in the center of the room are analyzed due to their variations. The square window type, which forms the elevation of the square window by exposing the columns to the elevation, and the outframe type, which protrudes from the structural columns and beams, have elevation designs limited. There are, however, no obstacles to the interior space of the hospital room, so the wall composition and furniture arrangement are expected to be free. The ward area of Curtain Wall Type A, which can secure an effective area of 5.9m*5.0m, are 52.1m2. The Curtain Wall Type A, Square window type, and the outframe type are 49.8m2. Implications: As part of the hospital standard module plan for economical and reasonable hospital building planning, a type was proposed in this study in conjunction with the external design. It is hoped that it be a base for standard module research linked together to the Central Treatment department, Outpatient department and underground parking lot.