• Title/Summary/Keyword: 변전소 협조제어

Search Result 8, Processing Time 0.038 seconds

On-line coordination control of OLTC and Switched Shunt for enhancement of stability using local data in substation (변전소내 지역정보를 이용하여 안정도 향상을 위한 실시간 OLTC 및 커패시터 협조제어 알고리즘)

  • Kang, Sang-Gyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.119-125
    • /
    • 2012
  • This paper suggest the on-line coordination control between on-load tap changers and Switched Shunts for ensuring the voltage stability using local data obtained from one substation. Inappropriate control of on-load tap changers that are able to maintain voltage profile might cause unintended result that is harmful to system stability, especially voltage stability. This paper utilizes Z-index that could inform the whole system condition from only one substation data. Simulation is performed using the HYPERSIM that is a digital simulator and matlab simulink to confirm the proposed algorithm.

Cooperated control between Load Tap Changer, Shunt Capacitor, FACTS in substation for voltage profile improvement (전압 Profile 개선을 위한 변전소 내의 LTC, S.C, FACTS간 협조제어 연구)

  • Lee, Gil-Soo;Kang, Sang-Gyun;Lee, Byung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.167-168
    • /
    • 2008
  • 이 논문은 변전소 환경에서 LTC, S.C, FACTS 간의 협조제어를 통한 전압 profile 개선을 논한다. 변전소 자체 내의 전압-무효전력 제어기기인 LTC, S.C 이외에도 현재에는 더 나은 전력전송과 전압안정을 위해 FACTS를 설치하는 경우가 늘고 있기 때문에 위의 3가지기기에 대한 협조제어 알고리즘에 대한 필요성은 점차 증대된다고 할 수 있다. 이러한 3가지 기기들의 협조제어를 통해서 전압 profile 개선에 관하여 연구하였으며 그러한 연구들은 Hypersim(real-time simulator) 기반에서 수행하였다.

  • PDF

A study on voltage control system for 154kV substation (154kV 변전소 전압제어시스템에 대한 연구)

  • Jung, Kwang-Ho;Choi, Seung-Il;Song, Jae-Won;Kim, Jong-Woo;Yun, Byung-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.121-123
    • /
    • 2007
  • 본 논문에서는 Shunt capacitor와 OLTC가 함께 설치된 154kV 변전소에서 송출전압을 고려한 두 기기의 협조제어 시스템에 대해 연구하고자 한다. Shunt Capacitor는 전압제어뿐 아니라 외란이 발생할 경우 안정도 제어에 매우 유용한 중요 기기이다. 그러나 비상시 안정도 제어에 참여하기 위해서는 평상운전 시 적정한 운전여유를 확보하고 있어야 한다. 또한 Shunt capacitor와 OLTC의 특성과 상호작용을 고찰하여 Shunt Capacitor의 무효전력 보상 여유를 유지하고 전압의 변동을 방지하면 OLTC의 탭동작을 최소화하여 고장의 요소를 방지하는 협조제어를 제안한다.

  • PDF

A Study on the Cooperation Program between ULTC and SVR for the Optimal Voltage Regulation (최적전압조정을 위한 ULTC와 SVR의 협조방안에 관한 연구)

  • Kim Mi Young;Rho Dae Seok
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.94-97
    • /
    • 2004
  • 최근 생활수준의 향상과 정보통신 산업의 급속한 발전으로 인하여 전세계적으로 전력품질에 대한 관심이 높아져, 각종 전력품질 개선장치로부터 최적 공급시스템에 이르기까지 다양한 각도에서 전력품질을 향상하기 위한 연구개발이 수행되고 있으며, 특히 정보통신기기 및 정밀제어기기 등의 보급증가로 전압품질에 대한 관심이 높아져가고 있다. 지금까지 배전계통의 전압관리는 배전용 변전소 ULTC(Under Load Tap Changer)와 고압배전선로의 주상변압기에 의해 조정되어 왔으며 최근에 고압배전선로의 전압강하가 $5\%$를 초과하는 선로에 대한 효율적 전압관리를 위해 선로전압조정장치(SVR- Step Voltage Regulator)가 도입되고있다. 그러나 배전용 변전소 ULTC와 고압배전선로의 SVR이 서로 독립적으로 운용되고 있기 때문에 SVR의 효율성이 멀어지고 있는 실정이다. 그러므로 본 논문에서는 변전소 ULTC와 SVR 송출전압의 최적 전압조정을 위한 협조운용 방안을 제시하고자 한다.

  • PDF

A development of multiple substation hybrid control algorithm using local subsystem data (지역 계통 정보를 이용한 다기 변전소 협조제어 알고리즘 개발)

  • Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.22_23
    • /
    • 2009
  • 자동화된 변전소의 전압 - 무효전력을 효율적으로 제어하기 위해서는 계통 상태에 따른 운전전략이 필요하다. 즉, 계통의 상태를 파악할 수 있는 안정도 지수를 이용하여, 그에 따른 ULTC와 S.S의 운전 방안의 수립이 요구된다. 이러한 사실을 바탕으로 본 논문에서는 사고 발생 시 계통 안정도를 유지할 수 있는 예방제어 측면과 계통 정보 모니터링을 통한 Tap과 S.S 사이의 협조제어 알고리즘을 제안한다.

  • PDF

A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation (변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구)

  • Jeong, Ki-Seok;Chang, Byun-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

EMTP Simulation for the Dynamic Analysis of a STATCOM-Shunts-OLTC Coordination in Substation (변전소 조상 설비간의 협조 제어를 위한 EMTP 과도해석모형 개발)

  • Jeong, Ki-Seok;Baek, Young-Sik;Park, Ji-Ho;Chang, Byung-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.237_238
    • /
    • 2009
  • This paper proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC. Voltage/Reactive power control has various difficult aspects to control because of analysis and system dynamics error. This coordinative control method suggests practical algorithm regarding system voltage and reactive power status which is easy to implement in substation basis. In normal status, STATCOM-Shunts-OLTC are in operation. The proposed algorithm is tested and verified in EMTP/RV. And this is expected to be applied to control multiple reactive power devices combined with SCADA/EMS system.

  • PDF

Local Coordinative Reactive Power Control Method to Manage Voltage/Momentary Reactive Reserve (전압 및 순동무효예비력 확보를 위한 지역 변전소에서의 무효전력제어장치 협조방식 연구)

  • Lee, Geun-Joon;Yoon, Jong-Soo;Jang, Byung-Hoon;Jung, Sung-Won;Yoon, Sun-Ho;Lee, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.115-116
    • /
    • 2008
  • This paper discusses local reactive power control method of substation which has FACTS controller(STATCOM) and other reactive power controllers. Not only The relation between entral control and local control method was discussed, but also local STATCOM control methd was done. With this results, revised coordinative control method which can implement system voltage sensitivity characteristics of each control devices. Also, this method can give proper solution for system status which requires momentary reactive reserve. This method is expected to be applied to control multiple substation reactive power devices which is combined with SCADA system.

  • PDF