• Title/Summary/Keyword: 변위응답

Search Result 598, Processing Time 0.028 seconds

An Experimental Study on Dynamic Behavior Evaluation of Transitional Track (접속부 궤도의 동적거동분석을 위한 실험적 연구)

  • Cho, Sung-Jung;Choi, Jung-Youl;Chun, Dae-Sung;Kim, Man-Cheol;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1379-1385
    • /
    • 2007
  • In domestic transitional zone design, there is regulation to prevent generation of irregular substructure behaviors that negatively influence in prevention of plasticity settlement on approach section and contact section as well as relieve overall track rigidity by reducing sectional foundation and track stiffness difference, but design guideline that considers dynamic behavior of transitional track in actual service line is very insignificant. Therefore in this study, characteristics of transitional track dynamic behaviors by substructure stiffness are researched and measured dynamic response of transitional track by substructure stiffness in order to prove correlation between substructure and track and calculate elasticity(stiffness) and track load of transitional track by using measurement and formula to provide basic information for developing design guideline considering dynamic behavior of service line transitional track.

  • PDF

Characteristics of Aerodynamic Damping on Helical-Shaped Super Tall Building (나선형 형상의 초고층건물의 공력감쇠의 특성)

  • Kim, Wonsul;Yi, Jin-Hak;Tamura, Yukio
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Characteristics of aerodynamic damping ratios of a helical $180^{\circ}$ model which shows better aerodynamic behavior in both along-wind and across-wind responses on a super tall building was investigated by an aeroelastic model test. The aerodynamic damping ratio was evaluated from the wind-induced responses of the model by using Random Decrement (RD) technique. Further, various triggering levels in evaluation of aerodynamic damping ratios using RD technique were also examined. As a result, it was found that when at least 2000 segments were used for evaluating aerodynamic damping ratio for ensemble averaging, the aerodynamic damping ratio can be obtained more consistently with lower irregular fluctuations. This is good agreement with those of previous studies. Another notable observation was that for square and helical $180^{\circ}$ models, the aerodynamic damping ratios in along-wind direction showed similar linear trends with reduced wind speeds regarding of building shapes. On the other hand, for the helical $180^{\circ}$ model, the aerodynamic damping ratio in across-wind direction showed quite different trends with those of the square model. In addition, the aerodynamic damping ratios of the helical $180^{\circ}$ model showed very similar trends with respect to the change of wind direction, and showed gradually increasing trends having small fluctuations with reduced wind speeds. Another observation was that in definition of triggering levels in RD technique on aerodynamic damping ratios, it may be possible to adopt the triggering levels of "standard deviation" or "${\sqrt{2}}$ times of the standard deviation" of the response time history if RD functions have a large number of triggering points. Further, these triggering levels may result in similar values and distributions with reduced wind speeds and either may be acceptable.

Seismic response characteristics of the hypothetical subsea tunnel in the fault zone with various material properties (다양한 물성의 단층대를 통과하는 가상해저터널의 지진 시 응답 특성)

  • Jang, Dong In;Kwak, Chang-Won;Park, Inn-Joon;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1061-1071
    • /
    • 2018
  • A subsea tunnel, being a super-sized underground structure must ensure safety at the time of earthquake, as well as at ordinary times. At the time of earthquake, in particular, of a subsea tunnel, a variety of response behaviors are induced owing to relative rigidity to the surrounding ground, or difference of displacement, so that the behavior characteristics can be hardly anticipated. The investigation aims to understand the behavior characteristics switched by earthquake of an imaginary subsea tunnel which passes through a fault zone having different physical properties from those of the surrounding ground. In order to achieve the aim, dynamic response behaviors of a subsea tunnel which passes through a fault zone were observed by means of indoor experiments. For the sake of improved earthquake resistance, a shape of subsea tunnel to which flexible segments have been applied was considered. Afterward, it is believed that a D/B can be established through 3-dimensional earthquake resistance interpretation of various grounds, on the basis of verified results from the experiments and interpretations under various conditions. The present investigation performed 1 g shaking table test in order to verify the result of 3-dimensional earthquake resistance interpretation. A model considering the similitude (1:100) of a scale-down model test was manufactured, and tests for three (3) Cases were carried out. Incident seismic wave was introduced by artificial seismic wave having both long-period and short-period earthquake properties in the horizontal direction which is rectangular to the processing direction of the tunnel, so that a fault zone was modeled. For numerical analysis, elastic modulus of the fault zone was assumed 1/5 value of the modulus of individual grounds surround the tunnel, in order to simulate a fault zone. Resultantly, reduced acceleration was confirmed with increase of physical properties of the fault zone, and the result from the shaking table test showed the same tendency as the result from 3-dimensional interpretation.

Optimization of a Cam Profile in a Circuit Breaker to Improve Latching Performance (캠 윤곽 최적설계를 통한 차단기 래칭 성능 향상)

  • Lee, Jae Ju;Jang, Jin Seok;Park, Hyun Gyu;Yoo, Wan Suk;Kim, Hyun Woo;Bae, Byung Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.73-79
    • /
    • 2016
  • Higher circuit breaker safety standards can be obtained by increasing the sustaining time of the latching section. This time increase is achieved through velocity reduction after contacting when the closing mechanism operates. The potential for the re-closing phenomenon to occur is also reduced by obtaining time to return open latch. In this study, the sustaining time for the latching section was increased through cam profile optimization based on the displacement response of the moving parts. In addition, the existing performance velocity was also satisfied. A multibody dynamics model of the circuit breaker was developed using ADAMS. To validate the model, simulation results were compared to experiment results. Then, cam profile optimization was carried out using an optimal design program PIAnO. Design variables selected included the radial direction of the cam. Design sensitivity analysis was carried out by design section as well. As a result of optimization, the sustaining time for the latching section was increased.

Development of a Test Rig with Hydraulic Circuit for the Front Axle Suspension System of an Agricultural Tractor (농용트랙터 전방차축 현가장치를 위한 유압회로 시험기 개발)

  • Lee, Jung-Hwan;Cho, Bong-Jin;Kim, Hak-Jin;Koo, Kang-Mo;Ki, In-Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.71-71
    • /
    • 2017
  • 농용트랙터의 운전자는 작업, 주행으로 인한 유해한 저주파 진동에 장시간 노출된다. 이에 따라 운전자에게 전달되는 노면 진동을 감소시켜주기 위한 전방차축 현가장치의 역할이 커지고 있다. 트랙터의 전방차축 현가장치는 주로 유압식으로 설계되어 있으며 이를 구성하는 유압요소 선정이 현가장치의 성능에 중요한 영향을 미친다. 하지만, 실제와 유사한 조건에서 트랙터 차체 무게만큼 큰 부하를 제공하여 유압회로의 성능을 실험하는 것은 비용과 시간 측면에서 비효율적이다. 본 연구에서는 이를 대체하기 위하여 개별 유압요소의 성능을 테스트 할 수 있는 현가장치 유압회로 요인 시험기를 설계제작 하였다. 이를 이용하여 개별 부품의 성능곡선을 센서를 이용 측정하였고 얻은 특성값을, 구성한 유압 시뮬레이션 모델에 반영하여 실제조건의 유압특성을 얻을 수 있는 유효한 시뮬레이션 모델 개발에 활용하였다. 또한, 실험실 환경에서 유압식 현가장치를 간소화 시킨 형태로 유압회로의 성능을 예비시험해 볼 수 있도록 다양한 센서를 장착 데이터를 취득할 수 있도록 하였다. 개발한 요인 시험기는 하부에 설치된 가진 실린더를 이용하여 상부에 설치된 현가장치 실린더의 스트로크 변위와 속도에 따른 힘을 측정할 수 있도록 구성하였다. 이를 위해 현가장치 실린더의 헤드부와 로드부에 각각 압력센서를 설치하였으며 헤드부, 로드부의 압력 차이와 로드셀을 이용해 측정한 가진 실린더의 힘의 관계를 확인하였다. 상부의 현가 실린더 장치는 복동 형태로 제작되어 헤드부, 로드부 양쪽 방향으로 유량이 흐를 수 있도록 설계되었다. 이를 이용해 헤드부와 로드부 사이에 어큐뮬레이터, 가변 오리피스, 릴리프 밸브 등으로 유압회로를 구성하였으며 어큐뮬레이터 용량에 따른 힘의 변화, 가변 오리피스의 개도량에 따라서 전달되는 힘의 크기 등을 측정하였다. 하부의 가진 실린더는 사인파, 삼각파, 계단 입력, DC 레벨 등의 신호를 발생시킬 수 있도록 제작되었다. 신호의 주파수는 0~4Hz, 범위에서 사용자가 조절할 수 있도록 설정되었으며 계단응답 성능 측정 시험을 평가한 결과 정상상태오차는 0.470mm~0.536mm, 입상시간은 0.194초~0.202초, 정착시간은 0.230초~0.421초로 나타났다.

  • PDF

Seismic Amplification Characteristics of Eastern Siberia (동시베리아 지역의 지진 증폭 특성)

  • Park, Du-Hee;Kwak, Hyung-Joo;Kang, Jae-Mo;Lee, Yong-Gook
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.67-80
    • /
    • 2014
  • The thickness of permafrost in Eastern Siberia is from 200 to 500 meters. The seasonally frozen layer can vary from 0 to 4m depending on ground temperature and its location. The shear wave velocity varies from 80m/s in summer to 1500m/s in winter depending on soil type. When melted, large impedence will occur due to the difference between the shear wave velocity of seasonally frozen soil and that of permafrost layer. Large displacement may occur at the boundary of the melted and the frozen layer, and this phenomenon should be considered in a seismic design. In this research, one-dimensional equivalent linear analyses were performed to investigate the effects of the seasonally frozen layer on ground amplification characteristics. Soil profiles of Yakutsk and Chara in Eastern Siberia were selected from geotechnical reports. 20 recorded ground motions were used to evaluate the effect of input motions. As the thickness of seasonally frozen layer and the difference in the shear wave velocity increases, the amplification is shown to increase. Peat, very soft organic soil widely distributed throughout Eastern Siberia, is shown to cause significant ground motion amplification. It is therefore recommended to account for its influence on propagated motion.

Demand Strength Spectrums of Low-Rise Reinforced Concrete Buildings Consisted of Extremely Brittle, Shear and Flexural Failure Systems (극취성·전단·휨파괴형 수평저항시스템으로 구성된 저층 철근콘크리트 건물의 요구 내력 스펙트럼)

  • Lee, Kang-Seok;Kim, Jeong-Hee;Oh, Jae-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.529-537
    • /
    • 2007
  • The purpose of this study is to discuss how strength and ductility of each system in low-rise reinforced concrete buildings composed of extremely brittle, shear and flexural failure lateral-load resisting systems have influence on seismic capacities of the overall system, which is based on nonlinear seismic response analyses of single-degree-of-freedom structural systems. In order to simulate the triple lateral-load resisting system, structures are idealized as a parallel combination of two modified origin-oriented hysteretic models and a degrading trilinear hysteretic model that fail primarily in extremely brittle, shear and flexure, respectively. Stiffness properties of three models are varied in terms of story shear coefficients, and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of demand strengths of the triple system for various levels of ductility factors are finally derived for practical purposes. The result indicates that demand strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete buildings having the triple lateral-load resisting system.

Study of the Long-Term Behavior Characteristics of Roadbed on Concrete Track of High-speed Railway (고속철도 콘크리트 궤도상 토공노반의 장기거동 특성 연구)

  • Choi, Chan-Yong;Jung, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.8-16
    • /
    • 2018
  • This study examined the long-term behavior of a roadbed using high-speed railway concrete track and roadbed measurement data and evaluated the long-term performance of the track and roadbed. Recently, high-speed railway track type has been adopted as a concrete slab. On the other hand, the concrete track is vulnerable to roadbed settlement. In the case of gravel tracks, it is easy to restore the original state by maintenance even if the roadbed settles. On the other hand, in the case of the concrete track, if excessive settlement of the roadbed occurs, cracks are generated continuously on the slabs and sleepers, resulting in greatly reduced usability. For this reason, it is difficult to restore the original state only by partial maintenance. In this paper, a long-term performance evaluation was carried out on a concrete track during operation by monitoring the measurement data of sensors buried from the beginning of construction for approximately 3 years after the high-speed railway opened. Performance evaluation methods include a performance evaluation of track/roadbed when the train passes, long-term track and roadbed performance evaluation, analysis of the track/roadbed effect on long-term settlement and analysis of the factors influencing long-term settlement. The trail response of KTX-Sancheon was greatest in the track/roadbed performance evaluation by train. The results of the long-term track and roadbed performance evaluation were measured within the standard values. The track and roadbed performance impact assessment with long-term settlement was strongly related to TCL settlement. The influences of the water content and groundwater level were verified by analyzing the external factors of long-term settlement. Through such a method, the stability of a track/roadbed can be secured.

A Study on the High Pressure Pump Simulation Model of a Diesel Injection System (디젤 분사시스템의 고압펌프 시뮬레이션 모델에 대한 연구)

  • Kim, Joongbae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.102-109
    • /
    • 2017
  • The high pressure pump of a diesel injection system compresses the fuel supplied at low pressure into high pressure fuel and maintains the fuel of the common rail at the required pressure level according to the engine operating conditions. The high pressure pump is required to operate normally in order to compress the fuel to a high pressure of 2000 bar during the entire lifetime of the vehicle. Consequently, a suitable design technique, material durability and high precision machining are required. In this study, the high pressure pump simulation model of a 1-plunger radial piston pump is modelled by using the AMESim code. The main simulation parameters are the displacement, flow rate and pressure characteristics of the inlet and outlet valves, cam torque characteristics, and operating characteristics of the fuel metering valve and overflow valve. In addition, the operating characteristics of the pump are simulated according to the parameter changes of the hole diameter and the spring initial force of the inlet valve. The simulation results show that the operation of the developed pump model is logically valid. This paper also proposes a simulation model that can be used for current pump design changes and new pump designs.

A Simple Seismic Vulnerability Sorting Method for Electric Power Utility Tunnels (전력구의 간편 지진취약도 선별법)

  • Kang, Choonghyun;Huh, Jungwon;Park, Inn-Joon;Hwang, Kyeong Min;Jang, Jung Bum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.110-118
    • /
    • 2018
  • Due to recent earthquakes, there is a growing awareness that Korea is not a safe zone for earthquakes any more. Therefore, the review of various aspects of the seismic safety of the infrastructures are being carried out. Because of the characteristics of the underground structure buried in the ground, the electric power utility tunnels must be considered not only for the inertia and load capacity of the structure itself but also the characteristics of the surrounding soils. An extensive and accurate numerical analysis is inevitably required in order to consider the interaction with the ground, but it is difficult to apply the soil-structure interaction analyses, which generally requires high cost and extensive time, to all electric power utility tunnel structures. In this study, the major design variables including soil characteristics are considered as independent variables, and the seismic safety factor, which is the result of the numerical analysis, is considered as a dependent variable. Thus, a method is proposed to select vulnerable electric power utility tunnels with low seismic safety factor while excluding costly and time-consuming numerical analyses through the direct correlation analysis between independent and dependent variables. Equations of boundary limits were derived based on the distribution of the seismic safety factor and the cover depth and rebar amounts with high correlation relationship. Consequently, a very efficient and simple approach is proposed to select vulnerable electric power utility tunnels without intensive numerical analyses. Among the 108 electric power utility tunnels that were investigated in this paper, 30% were screened as fragile structures, and it is confirmed that the screening method is valid by checking the safety factors of the fragile structure. The approach is relatively very simple to use and easy to expand, and can be conveniently applied to additional data to be obtained in the future.