• Title/Summary/Keyword: 변연형태

Search Result 95, Processing Time 0.026 seconds

Fitness of Adjustable Dental Impression Trays on the Caucasian and African American (백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Park, Yong-Suck;Kim, Yu-Lee;Oh, Sang-Cheon;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.185-192
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Caucasian and African American. Material and methods: The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. Sixty Caucasian (male:30, female:30) and sixty African American (male:30, female:30) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. Results: 1. Uniform impression material width was achieved by controling the width of the tray using stops and beveled guides. 2. In the maxillary tray on the Caucasian, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 13.0 mm. 3. In the maxillary tray on the African American, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 12.0 mm, posterior palatal part 11.0 mm and the labial frenum width was 11.0 mm. 4. In the maxillary tray on the African American, the impression material width of posterior border (0.8 mm) was measured to be small. 5. In the mandibular tray on the Caucasian, the impression material width was measured (2.7-6.7 mm) and posterior border width (2.1 mm) was measured small. The impression material length was measured (2.8-6.7 mm). 6. In the mandibular tray on the African American, the impression material width was measured to be rather great showing width of the labial frenum 9.2 mm and the width of posterior border was measured too small (0.3 mm). Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Caucasian and African American, we can take more easy and accurate dental impressions.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

ALTERNATIVE TECHINQUE OF MATRIX BANDING FOR RESTORING OF PROXIMAL CARIOUS LESIONS IN PRIMARY ANTERIOR TEETH (유전치 인접면우식증의 복합레진 충전시 변형된 matrix band의 사용)

  • Ra, Ji-Young;Cho, Hyun;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.453-458
    • /
    • 2003
  • Usually Mylar strip and wedge or celluloid strip crown were used in conventional method of restoring proximal carious lesions of primary anterior teeth. But, these methods have some difficulties to place the matrix and wedge due to short crown lenth and interdental spacing of primary teeth. And it is difficult to form proper cavosurface margin due to the rigidity of matrix and inconvenience to support matrix by practitioner's hand in narrow oral cavity of child. This article describes an alternative technique for restoring carious lesions of primary anterior teeth using available straw. This method is very convenient and reduce chair time and it also allows good marginal adaptation.

  • PDF

MTA APPLICATION TO PATIENTS WITH CELLULITIS CAUSED BY DENS EVAGINATUS (치외치로 인한 봉와직염 환자에서 MTA를 이용한 치험례)

  • Koo, Jung-Eun;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.310-317
    • /
    • 2009
  • Dens evaginatus is a dental anomaly involving an extra cusp or tubercle that protrudes from the occlusal surface of the affected tooth. The prevalence of dens evaginatus is 1 to 4 percent, and dens evaginatus is observed most commonly in premolars. It can be worn or fractured easily, resulting in pulpal exposure, pulpal infection, loss of vitality, facial infection and osteomyelitis. Since the tooth frequently has the immature apex when the tubercle is fractured, there is difficulty in treatment. Although calcium hydroxide is widely used for pulp treatment of an immature permanent tooth, several alternatives have been suggested to reduce patient's appointments. Mineral trioxide aggregate is considered biocom-patible and has excellent marginal sealing ability. In addition, it can minimize patient's visits. In this case report, apexification with MTA was attempted on the immature premolars in patients with cellulitis patient, caused by pulp necrosis due to dens evaginatus. Favorable clinical and radiologic results were achieved. In one case, continued root formation was observed.

  • PDF

Diagnostic Imaging of Isolated Splenic Torsion in a German Shepherd Dog (독일셰퍼드 견에서 단독으로 발생한 비장 염전의 영상진단)

  • Lee, Ki-Ja;Jeong, Seong-Mok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.613-616
    • /
    • 2011
  • A 5-year-old male German shepherd dog was presented with a 4 day-history of anorexia and depression. Abdominal radiographs showed a large soft tissue mass and loss of serosal detail. Ultrasonographs revealed splenomegaly with the lacy pattern parenchyma, perivenous hyperechoic region at the splenic hilum, and loss of splenic venous flow. Computed tomographic findings included the enlarged non-enhanced spleen except perivenous region at the splenic hilum and a whirled soft tissue mass at the splenic hilum. Exploratory laparotomy confirmed the diagnosis of splenic torsion. Ultrasonographic findings including lacy appearance, hyperechoic perivenous echogenicity and absence of splenic blood flow and CT findings including no or minimal enhancement of the spleen and a whirled appearance of splenic pedicle could be useful for diagnosing isolated splenic torsion in the dog.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION (와동형태가 5급 와동 수복물의 변연누출에 미치는 영향)

  • Park, Jeong-Kil;Hur, Bock;Lee, Hee-Ju
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

An Experimental Study on the Effects of the Margin Designs and Composite Resins on the Marginal Leakage of Class V Resin Restorations (V 급 와동 변연부 형태 및 복합레진 종류에 따른 변연 누출에 관한 실험적 연구)

  • Sin, Yong-Pil;Lee, Chan-Young;Lee, Seung-Jong;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.107-116
    • /
    • 1986
  • The primary aim of this study was to assess the effects of the margin designs and composite resins on the marginal leakage of Class V resin restorations. 60 Class V cavities with $90^{\circ}$ butt joint, 60 with $45^{\circ}$ bevel joint, and 60 with concave joint were prepared on the labial surfaces of 38 extracted anterior teeth and the buccal and lingual surfaces of 71 premolars, and classified as the butt group, bevel group and concave group, respectively. After completion of the cavity preparation, Heliosit${(R)}$ was filled in 20 butt joint cavities, 20 bevel joint cavities, and 20 concave cavities. And Hi-Pol$^{(R)}$ and Palfique$^{(R)}$ were filled in the same manner, respectively. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$, $37^{\circ}C$, and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours, and buccolingually sectioned with sectioning machine. The sectioned specimens were examined under the light microscope. The results indicated the following: 1. The bevel group showed the least amount of marginal leakage compared with the other two design groups, but the statistical analysis showed no significant difference at the 95% confidence level. 2. Hi-Pol$^{(R)}$ group showed the most severe marginal leakage compared with the other composite resin materials, but there was no significant difference in the groups. 3. The bevel-Heliosit$^{(R)}$ subgroup, which was filled with Heliosit$^{(R)}$ in the beveled cavities, showed the least amount of marginal leakage, but there was no significance in all the subgroups.

  • PDF

Long-term Evaluation of IMZ Implants;Success and Survival Rates (IMZ 임플란트의 장기적 성공률과 실패율)

  • Park, Ji-Eun;Kim, Tae-Gyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.1039-1052
    • /
    • 2005
  • IMZ는 "intramobile cylinder implant system" (IMZ)로 독일에서 가장 오래되고 많이 사용되어진 임플란트 중 하나이다. 이 임플란트에 관한 장기적 성공률과 생존률에 대한 연구는 대개 80% 이상을 보고하고 있다. 그러나, 연세대학교 치과병원 치주과에서 식립된 83개의 임플란트에서는 이전의 연구와는 다른 결과를 나타내었다. 1. IMZ 임플란트의 생존률은 67.5% 였다. 2. 변연 치조골 소실에 대한 성공 기준을 적용한 결과 성공률은 49.4%로 나타났다. 3. 발거된 총 27개의 임플란트 중에서 임플란트 주위 골소실을 가지는 경우는 17개, 내부구조 파절은 4개, 식립체 파절은 5개로 보고되었다. 4. 10년 이상 생존된 임플란트에서 변연골 소실의 평균치는 2.82mm였다. IMZ 임플란트는 장기적으로 높은 실패율을 보고하였다. 이는 cylindrical design, titanium plasma flame spray coating, prosthodontic complication 등의 요소에 기인한 것으로 사료된다. 임플란트는 그 형태, 표면 처리 등 여러 가지 요인들에 의해 실패가 나타날 수 있으며 본 연구를 통해 임플란트의 개발 및 선택에 바탕이 될 수 있을 것으로 생각된다.