• Title/Summary/Keyword: 벽면유동

Search Result 432, Processing Time 0.023 seconds

Local Convective Mass Transfer and Flow Structure Around a Circular Cylinder with Annular Fins (환상핀이 부착된 원봉 주위의 3차원 박리 유동구조 및 물질전달 특성 해석)

  • 박태선;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2132-2146
    • /
    • 1991
  • Extensive experiments were carried out to investigate the mass transfer and flow structures around a circular cylinder with annular fins in crossflow. The naphthalene sublimation method was employed to measure the circumferential and longitudinal variations of mass transfer from the circular cylinder between annular fins and H is the height of the fin from the cylinder surface. A remarkable enhancement of mass transfer due to the horseshoe vortices was observed near the corner junction between the annular fin and circular cylinder. The present results indicate that the local circumferential Sherwood number shows the higher values on the front stagnation point. The maximum augmentation of mass transfer rate at the center of cylinder is found near L/H-0.15 due to the separation bubble along the annular fins. The secondary flows, which are the corner vortices V2 and V3 near the end wall of the annular fin, are fairly predicted from the distributions of local Sherwood number in the spanwise direction. The average Sherwood number of overall surface at L/H=0.15 is larger 2.0 times than that of without annualr fins. The correlations of total average mass transfer rate with L/H and Re$_{L}$ can also be obtained.d.

Numerical Analysis of Incompressible and Compressible Flow Around a Butterfly Valve (버터플라이 벨브 주위의 비압축성 및 압축성유동 특성에 대한 수치해석)

  • 이종욱;이두환;최윤호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • In this paper, incompressible and compressible flow characteristics around the butterfly valve have been investigated. In order to simplify the problem, a flat disk valve with various valve disk angles and pressure ratios is considered in the present calculations. It was found that as the disk angle increases, the stagnation point on the front surface of the disk moves to the center of the surface and the inflow velocity decreases. The maximum flow velocity occurs at the downstream of throat because of the formation of vents contracta. As the pressure ratio decreases, compressibility effects increase and the jet formed between the throttle body wall and the disk edge becomes supersonic. This flow also builds up as a shock cell structure. The increase of disk angle and pressure ratio makes the mass flow at the inlet decrease, while the increase of disk angle and the decrease of pressure ratio make the pressure loss coefficient increase.

An Experimental Study on Flow Characteristics of Turbulent Pulsating Flow in a Curved Duct by using LDV (LDV에 의한 곡관덕트에서 난류맥동유동의 유동특성에 관한 실험적 연구)

  • Lee, Hong-Gu;Son, Hyun-Chul;Lee, Haeng-Nam;Park, Gil-Moon
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.397-403
    • /
    • 2000
  • In the present study, flow characteristics of turbulent pulsating flow in a square-sectional $180^{\circ}$ curved duct were experimentally investigated. Experimental studies for air flows were conducted to measure axial velocity and wall shear stress distributions and entrance length in a square-sectional $180^{\circ}$ curved duct by using the LDV with the data acquisition and the processing system. The experiment was conducted in seven sections from the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) at $30^{\circ}$ intervals of the duct. The results obtained from the experimentation were summarized as follows ; (1) When the ratio of velocity amplitude ($A_1$) was less than one, there was hardly any velocity change in the section except near the wall and any change in axial velocity distributions along the phase. When the ratio of velocity amplitude ($A_1$) was 0.6, the change rate of velocity was slow. (2) Wall shear stress distributions of turbulent pulsating flow were similar to those of turbulent steady flow. The value of the wall shear stress became minimum in the inner wall aid gradually increased toward the outer wall where it became maximum. (3) The entrance length of turbulent pulsating flow reached near the region of bend angle of $90^{\circ}$, like that of turbulent steady flow. The entrance length was changed by the dimensionless angular frequency (${\omega}^+$).

  • PDF

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF

Experimental Investigation on Heat Transfer Characteristics in a Uniformly Heated Pipe with Pulsating Pressure (맥동 압력을 받는 가열관 내부에서의 열전달 특성에 관한 실험적 연구)

  • 이건태;강병하;이재헌;이춘식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1760-1769
    • /
    • 1992
  • An experimental study of thermal transport from a uniformly heated pipe to a pulsating flow has been carried out. Surface of the pipe is imposed with constant heat flux providing by electric heating band. This problem is of particular interest in the design of Stirling engine heat exchangers and in understanding the blood flow in the aorta. Temporal Variatiens of temperature and pressure inside the circular pipe are measured. The dependence of temperature distributions and heat transfer rate on the mean flow rate in the pipe and on the pulsating frequency is investigated in detail. The experimental results indicate that the measured temporal variations of temperature and pressure become nearly sinusoidal The amplitude of temperature variation near the pipe wall is much more substantial than that in core of the pipe. It is also found that the heat transfer rate is increased significantly as the frequency of the pulsating pressure is increased or the mean flow rate in a pipe is increased. The results obtained are also compared with those for non-pulsating flow circumstance.

3-D Flow Analysis of Blood and Blood Substitutes in a Double Branching Model (이중 분지관내 혈액 및 혈액대용유체의 3차원 유동해석)

  • Suh, Sang-Ho;Yoo, Sang-Sin;Roh, Hyung-Woon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.187-196
    • /
    • 1997
  • The three-dimensional flow analysis using the finite volume method is presented to compare the steady flow characteristics of blood with those of blood substitutes such as water and aqueous polymer solution in an idealized double branching model. The model is used to simlllate the region of the abdominal aorta near the celiac and superior mesenteric branches. Apparent viscosities of blood and the aqueous Separan solution are represented as a function of shear rate by the Carreau model, Water and aqueoiu Separan AP-273 500wppm solution are frequently used as blood substitutes in vitro experiments. Water is a typical Newtonian fluid and blood and Separan solution are non-Newtonian fluids. Flow phenomena such as velocity distribution, pressure variation and wall shear stress distribution of water, blood and polymer solution are quite different due to differences of the rheological characteristics of fluids. Flow phenomena of polymer solution are qualitatively similar to those of blood but the phenomena of water are quite different from those of blood and polymer solution. It is recommended that a lion-Newtonian fluid which exhibits very similar rheological behavior to blood be used in vitro experiments. A non-Newtonian fluid whose rheological characteristics are very similar to those of blood should be used to obtain the meaninylll hemodynamic data for blood flow in vitro experiment and by numerical analysis

  • PDF

Numerical Study of Flow Pattern and Drug Deposition in Drug-Eluting Stent (약물분출 스텐트 주위 유동형태와 약물침전에 대한 수치해석)

  • Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1053-1060
    • /
    • 2011
  • This study is performed to determine the drug concentration profiles of drug-eluting stents (DES) for an ideal circular ring stent and intertwined stent models for various Reynolds numbers (Re = 200, 400, and 800). The Navier.Stokes equations coupled with the advection-diffusion equation are solved numerically in order to determine how the flow patterns and drug deposition are affected in the in-stent and post-stent regions where flow separation and recirculation occur. The presence of DES within the arterial segment affects the local drug distribution in the flow field. As a result, the drug concentration for the intertwined stent is higher over the in-stent region in comparison with the ideal stents. For a given stent geometry, the local drug concentration in the in-stent region decreases with Reynolds number, while for a given Reynolds number, the local drug concentration is relatively insensitive to the stent geometry. The results show that drug concentration along the arterial wall is significantly higher within the in-stent and post-stent regions for the intertwined stent geometry than for the ideal stent geometries.

Analysis of mixed convective laminar flow and heat transfer about a sphere (혼합대류에 의한 구 주위의 충류유동 및 열전달 해석)

  • 이준식;김택영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 1987
  • An analysis is performed to study flow and heat transfer characteristics of mixed free and forced convection about a sphere. Nonsimilar boundary layer equations which are valid over the entire regime of mixed convection are derived in terms of the mixed convection parameter, Gr/Re$^{2}$, through a dimensional analysis. The transformed conservation equations are solved by a finite difference method for the whole range of mixed convection regime. Numerical results for fluids having the Prandtl number 0.7 and 7 are presented. As the mixed convection parameter increases, the local friction coefficient and local heat transfer coefficient increases as well. For small Prandtl number, the friction coefficient is larger, while for large Prandtl number, the heat transfer coefficient is larger. Natural convection effect on the forced flow is more sensitive for small Prandtl number fluid. Flow separation migrates rearward as an increase in the mixed convection parameter. For small Prandtl number, the buoyancy effect is relatively small so that the flow separation occurs earlier.

A study on the heat transfer characteristics of swirling flow in a circular sectioned $180^{\circ}C$bend with uniform heat flux (균일 열플럭스가 있는 $180^{\circ}C$ 원형단면 곡관의 선회유동 열전달특성 연구)

  • Lee, Sang-Bae;Gwon, Gi-Rin;Jang, Tae-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.615-627
    • /
    • 1997
  • An experiment was performed to local heat transfer coefficient and Nusselt number in the circular duct of 180.deg. bend for Re=6*10$^{4}$, 8*10$^{4}$ and 1*10$^{5}$ at swirling flow and non-swirling flow conditions. The test tube with circular section was made by stainless which has curvature ratio 9.4. The wall of test tube was heated directly by electrical power to 3.51 kw and swirling motion of air was produced by a tangential inlet to the pipe axis at the 180 degree. Measurements of local wall temperatures and bulk mean temperature of air are made at four circumferential positions in the 16 stations. The wall temperatures show particularly reduced distribution curve at bend for non-swirling flow but this effect does not appear for swirling flow. Nusselt number distributions for swirling flow which was calculated from the measured wall and bulk temperatures were higher than that of non-swirling flow. Average Nusselt number of swirling flow increased about 90 ~ 100% than that of non-swirling flow whole through the test tube. The Nu/N $u_{DB}$ values at the station of 90.deg. for non-swirling flow and swirling flow are respectively about 2.5 and 4.8 at Re=6*10$^{4}$. Also that is good agreement with Said's result for non-swirling flow. flow.

Reactive Fields Analysis of Hybrid Combustor Under Different Arrangements of Oxidizer Injectors (하이브리드 연소기의 산화제 주입기 배열 특성에 따른 반응유동장 해석)

  • Cho Sung-Chan;Kim Soo-Jong;Lee Seung-Chul;Kim Jin-Kon;Koo Ja-Yae;Moon Hee-Jang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.2
    • /
    • pp.78-88
    • /
    • 2005
  • The combustion characteristics of End-Burning hybrid combustor using different types of injector system are numerically investigated to visualize the temperature fields in the combustion chamber The basic characteristics of combustion with different O/F ratio is also analyzed in order to capture the main behavior of diffusion flame inside the swirl induced hybrid combustion chamber It was found that the arrangement of oxidizer injectors give strong effect on the temperature field dominating mixing between fuel and oxidizer. The results show that among five different oxidizer injectors arrangement, the counter flow injector has the highest mixing efficiency. However, the observed high wall temperature presence near the oxidizer injectors remains to be solved.