• Title/Summary/Keyword: 베이스밴드

Search Result 63, Processing Time 0.029 seconds

Wireless Communication using Millimeter-Wave Envelope Detector (밀리미터파 포락선 검파기를 이용한 무선통신)

  • Lee, Won-Hui;Jang, Sung-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.79-82
    • /
    • 2017
  • In this paper, we proposed the wireless communication system using millimeter-wave envelope detector. The sub-harmonic mixer based on schottky barrier diode was used in the transmitter. The receiver was used millimeter-wave envelope detector. The transmitter was composed of schottky diode sub-harmonic mixer, frequency tripler, and horn antenna. The receiver was composed of horn antenna, millimeter-wave envelope detector, low pass filter, base band amplifier, and limiting amplifier. At 1.485 Gbps and 300 GHz, the eye-diagram showed a very good performance as measured by the error free. Communication distance is reduced compared to the heterodyne receiver, but compact and lightweight is possible.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Design and Implementation of 5G mmWave LTE-TDD HD Video Streaming System for USRP RIO SDR (USRP RIO SDR을 이용한 5G 밀리미터파 LTE-TDD HD 비디오 스트리밍 시스템 설계 및 구현)

  • Gwag, Gyoung-Hun;Shin, Bong-Deug;Park, Dong-Wook;Eo, Yun-Seong;Oh, Hyuk-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.445-453
    • /
    • 2016
  • This paper presents the implementation and design of the 1T-1R wireless HD video streaming systems over 28 GHz mmWave frequency using 3GPP LTE-TDD standard on NI USRP RIO SDR platform. The baseband of the system uses USRP RIO that are stored in Xilinx Kintex-7 chip to implement LTE-TDD transceiver modem, the signal that are transceived from USRP RIO up or down converts to 28 GHz by using self-designed 28 GHz RF transceiver modules and it is finally communicated HD video data through self-designed $4{\times}8$ sub array antennas. It is that communication method between USRP RIO and Host PC use PCI express ${\times}4$ to minimize delay of data to transmit and receive. The implemented system show high error vector magnitude performance above 25.85 dBc and to transceive HD video in experiment environment anywhere.

Design of a CMOS Tx RF/IF Single Chip for PCS Band Applications (PCS 대역 송신용 CMOS RF/IF 단일 칩 설계)

  • Moon, Yo-Sup;Kwon, Duck-Ki;Kim, Keo-Sung;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.236-244
    • /
    • 2003
  • In this paper, RF and IF circuits for mobile terminals which have usually been implemented using expensive BiCMOS processes are designed using CMOS circuits, and a Tx CMOS RF/IF single chip for PCS applications is designed. The designed circuit consists of an IF block including an IF PLL frequency synthesizer, an IF mixer, and a VGA and an RF block including a SSB RF mixer and a driver amplifier, and performs all transmit signal processing functions required between digital baseband and the power amplifier. The phase noise level of the designed IF PLL frequency synthesizer is -114dBc/Hz@100kHz and the lock time is less than $300{\mu}s$. It consumes 5.3mA from a 3V power supply. The conversion gain and OIP3 of the IF mixer block are 3.6dB and -11.3dBm. It consumes 5.3mA. The 3dB frequencies of the VGA are greater than 250MHz for all gain settings. The designed VGA consumes 10mA. The designed RF block exhibits a gain of 14.93dB and an OIP3 of 6.97dBm. The image and carrier suppressions are 35dBc and 31dBc, respectively. It consumes 63.4mA. The designed circuits are under fabrication using a $0.35{\mu}m$ CMOS process. The designed entire chip consumes 84mA from a 3V supply, and its area is $1.6㎜{\times}3.5㎜$.

  • PDF

Real-time emotion recognition technology using individualization processemotional technology (개인화 프로세스를 적용한 실시간 감성인식 기술)

  • Ahn, Sang-Min;Whang, Min-Cheol;Kim, Dong-Keun;Kim, Jong-Hwa;Park, Sang-In
    • Science of Emotion and Sensibility
    • /
    • v.15 no.1
    • /
    • pp.133-140
    • /
    • 2012
  • We designed a novel individualization process for improving personal emotion recognitions in real time. The designed individualization process was performed by a neutralization algorithm of physiological signals, a subjective emotion reflection of a user updated by personal emotion rules in real time. The physiological signals such as PPG(Photoplethysmography), GSR(Galvanic skin reflex), and SKT(Skin temperature) were measured and analyzed to estimate an emotion states of users. Regulating the emotion status using by emotion rules was performed by reflecting subjective evaluations. The agreement of emotion recognition between of individualization and non-individualization method was estimated by 10 undergraduates (5 females, mean age: $22.1{\pm}2.2$) of Sangmyung University. During the emotion recognition test, 45 images were randomly presented to each participant five times. In results, the proposed individualization process showed the agreement of 71.67 % which was five times higher than when the process was not applied. Therefore, in this study, we demonstrated that the individualization process was significantly useful for customizing emotion recognitions of personal users in real time. The individualization process will be able to improve satisfactions in various emotion related applications and services in the nearer future.

  • PDF

Design and Verification of IEEE 802.15.4 LR-WPAN 2.4GHz Base-band for Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 위한 IEEE 802.15.4 LR-WPAN 2.4GHz 베이스 밴드 설계 및 검증)

  • Lee Seung-Yerl;Kim Dong-Sun;Kim Hyun-Sick;Chung Duck-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.49-56
    • /
    • 2006
  • This paper describes the design and the verification of IEEE 802.15.4 LR-WPAN 2.4GHz Physical layer for Ubiquitous Sensor Network(USN). We designed the Carrier Frequency Offset(CFO) compensation satisfied the frequency tolerance of IEEE 802.15.4 LR-WPAN and the adaptive matched filter that re-setting of the threshold for the symbol synchronization of the various USN environment. The multiplications is reduced 1/16 by this method each other at i, q phases and has 0.5dB performance improvement in detection probability. Proposed baseband system is designed with verilog HDL and implemented using FPGA prototype board.

Content-based Image Retrieval using the Color and Wavelet-based Texture Feature (색상특징과 웨이블렛 기반의 질감특징을 이용한 영상 검색)

  • 박종현;박순영;조완현;오일석
    • Journal of KIISE:Databases
    • /
    • v.30 no.2
    • /
    • pp.125-133
    • /
    • 2003
  • In this paper we propose an efficient content-based image retrieval method using the color and wavelet based texture features. The color features are obtained from soft-color histograms of the global image and the wavelet-based texture features are obtained from the invariant moments of the high-pass sub-band through the spatial-frequency analysis of the wavelet transform. The proposed system, called a color and texture based two-step retrieval(CTBTR), is composed of two-step query operations for an efficient image retrieval. In the first-step matching operation, the color histogram features are used to filter out the dissimilar images quickly from a large image database. The second-step matching operation applies the wavelet based texture features to the retained set of images to retrieve all relevant images successfully. The experimental results show that the proposed algorithm yields more improved retrieval accuracy with computationally efficiency than the previous methods.

Design of Building Biomertic Big Data System using the Mi Band and MongoDB (Mi Band와 MongoDB를 사용한 생체정보 빅데이터 시스템의 설계)

  • Lee, Younghun;Kim, Yongil
    • Smart Media Journal
    • /
    • v.5 no.4
    • /
    • pp.124-130
    • /
    • 2016
  • Big data technologies are increasing the need for big data in many areas of the world. Recently, the health care industry has become increasingly aware of the importance of disease and health care services, as it has become increasingly immune to prevention and health care. To do this, we need a Big data system to collect and analyze the personal biometric data. In this paper, we design the biometric big data system using low cost wearable device. We collect basic biometric data, such as heart rate, step count and physical activity from Mi Band, and store the collected biometric data into MongoDB. Based on the results of this study, it is possible to build a big data system that can be used in actual medical environment by using Hadoop etc. and to use it in real medical service in connection with various wearable devices for medical information.

스퍼터링 및 셀렌화 공정 조건에 따른 C(IG)Se2 박막태양전지 제작과 특성

  • Choe, Seung-Hun;Son, Yeong-Ho;Jeong, Myeong-Hyo;Park, Jung-Jin;Lee, Jang-Hui;Kim, In-Su;Hong, Yeong-Ho;Yun, Jong-O
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.362-363
    • /
    • 2011
  • 태양광 발전산업에서 현재 주류인 결정 실리콘 태양전지의 변환효율은 꾸준히 향상되고 있으나, 태양전지의 가격이 매년 서서히 하강되고 있는 실정에서 결정질 실리콘 가격의 상승 등으로 부가가치창출에 어려움이 있으며, 생산 원가를 낮출 수 있는 태양전지 제조기술로는 2세대 태양전지로 불리는 박막형이 현재의 대안이며, 특히 에너지 변환 효율과 생산 원가에서 장점이 있는 것이 CIGS 박막태양전지로 판단된다. 화합물반도체 베이스인 CIGS 박막태양전지는 연구실에서는 세계적으로 20.3% 높은 효율을 보고하고 있으며, 모듈급에서도 13% 효율로 생산이 시작되고 있다. 국내에서도 연구실 규모뿐만 아니라 대면적(모듈급) CIGS 박막 태양전지 증착용 장비, 제조공정 등의 기술개발이 진행되고 있다. CIGSe2를 광흡수층으로 하는 CIGSe2 박막 태양전지의 구조는 여러 층의 단위박막(하부전극, 광흡수층, 버퍼층, 상부투명전극)을 순차적으로 형성시켜 만든다. 본 연구에서 광흡수층은 스퍼터링 방법으로 CIG precusor를 먼저 만들고, 그 위에 증발법으로 Se를 증착한 다음, 열처리 조건으로 CIGSe2 박막태양전지를 제작하였다. 제작된 CIGSe2 박막태양전지는 열처리 조건에 따라서 에너지 변환효율이 3.3에서 9.5%까지 다양하게 측정되었으며, 본 연구의 최고효율이 측정된 디바이스에서 개방전압은 0.48 V, 전류밀도는 33 mA/cm였으며, 그리드 전극을 제외한 디바이스의 면적은 0.57 cm2였다. 본 연구에서는 셀렌화 열처리 조건에 따른 CIGSe2 박막태양전지의 효율 측면을 고려하였지만, 더 높은 에너지 변환효율을 갖기 위해서 좀 더 높은 에너지 밴드갭과 개방전압, 낮은 직렬저항과 높은 shunt 저항 값 등의 상호 의존성에 대해서 연구결과들을 논하고자 한다.

  • PDF

Use of Music Technology in Music Therapy (음악치료에서의 음악테크놀로지 활용)

  • Park, Ye Seul
    • Journal of Music and Human Behavior
    • /
    • v.12 no.2
    • /
    • pp.61-77
    • /
    • 2015
  • The purpose of this study was to investigate music therapists'use and perception of computer-based music technology. Questionnaires were distributed either electronically or in-person to 367 music therapists with credentials. Of the 367 initially distributed questionnaires, 101 were returned and 61 were analyzed after excluding 40 incomplete responses. The survey was comprised of two sections: the use of music technology and perceived importance of music technology in music therapy practice. The results showed that 65.6% of the respondents had used music technology in their clinical practice. The most frequently used type of music technology was Finale, followed by Garage band, and Cubase. With regard to the areas where music technology was used, it was implemented primarily for adolescents for musical or emotional goals, and was applied most frequently as a musical resource. In addition, most respondents showed a positive attitude toward music technology and added that they would need to be trained to use music technology for their clinical practice. These results provide practical information on how music therapists use and perceive computer-based music technology, and its implication for music therapy clinical practice.