• Title/Summary/Keyword: 밸브개폐

Search Result 161, Processing Time 0.018 seconds

On the Force Balance of a Main Oxidizer Shutoff Valve (산화제 개폐밸브의 힘평형에 관한 연구)

  • Hong, Moon-Geun;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.14-17
    • /
    • 2008
  • A poppet type shutoff valve under the pneumatic control has been adapted for the MOV (Main Oxidizer shutoff Valve) for KSLV (Korea Space Launch Vehicle). The MOV controls the supply of liquid oxygen into the combustion chamber just by opening and shutting operations. The poppet part of the poppet valves is usually connected with the piston, but on the other hand that of the MOV is separated and just contacted with the piston in order to secure the flexibility of the valve design. For the prevention of the collision with valve body by an undesirable movement of the piston part, it is necessary to evaluate the force during the valve closing. The analysis of the force balance of the MOV at the moment of the valve closing have been performed and some important design parameters for the force balance control have been introduced.

  • PDF

Development of a Two-Step Main Oxidizer Shut-off Valve (2단계 개방 연소기 산화제 개폐밸브 개발)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.8
    • /
    • pp.704-710
    • /
    • 2017
  • The supply of the liquid oxygen into a rocket combustor is simply controlled by the 'on' and 'off' positions of a main oxidizer shut-off valve. However, the partially opened position of a three-position valve can control and optimize the engine start transients by regulating the liquid oxygen flow rate during the start-up of the engine. In this paper, the design and performances of a three-position pneumatic poppet valve, which is intended to be employed in liquid rocket engines, have been presented.

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

The change of hydraulic charictar in pipenetwork be followed by the opening and closing valve. (상수도 관망내 밸브 개폐에 따른 수리적 특성 변화)

  • Rhee Kyoung Hoon;Oh Chang Ju;Kim Tae Kyoung;Kim Ji Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.981-985
    • /
    • 2005
  • 상수도 관망은 상수도 운용시스템에서 가장 중요한 부분이다. 그러므로 항상 수요자의 필요에 부응하는 충분한 수량과 좋은 수질로 공급할 수 있도록 적정한 압력 유지와 수량 확보가 되도록 유지 관리 되어야 한다. 이를 위해서는 상수도 관망의 합리적인 해석과 최적의 설계를 통해 수요자가 필요로 하는 양질의 물을 원활히 공급하고 재원의 낭비를 줄여야 한다. 그러나 우리나라의 많은 대도시들의 경우처럼 특히 상수도 시설이 거대해 지고 급수구역이 광범위하며 복잡한 배수시설을 가지고 있는 지역에 있어서는 모든 현상을 정확하게 파악하고 유지관리하기가 매우 어렵게 되므로 운영관리상 많은 문제점이 발생하게 된다. 이러한 문제점에 보다 효율적으로 대처하기 위해서는 가장 기본적으로 현재의 상수도 시설에 대한 수리적 상태를 파악하여야 한다. 따라서 본 논문에서는 대도시 상수도 시설의 효율적 운영 및 확장에 기본이 되는 현재의 상수도 시설에 대한 시설현황, 운영, 수리상태를 파악 하고, 밸브의 개폐에 따른 수리학적 특성 변화를 제시하고자 하였다. 관망 해석에 필요한 입력 자료는 실제 운영되고 있는 광주광역시의 상수도 급배수 관망 시설을 대상으로 산출 하였고 관망해석 프로그램인 Pipenet 98을 이용하여 시뮬레이션을 실시하였다. 본 논문에서 대상 구역에 대해 수리적 특성 변화를 모의한 결과 상수 관로내의 밸브 개폐도를 $100\%$ 유지시켰을 때 평균 수압은 $4.4kg/cm^2$으로 나타났으며 밸브 개폐도 $80\%$일 때의 평균 수압 $4.7kg/cm^2$, 밸브 개폐도 $60\%$일 때의 평균 수압은 $4.69kg/cm^2$으로 나타났다. 밸브 개폐도가 $100\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.

  • PDF

Operating Characteristics of a Main Oxidizer Shut-off Valve According to Operating Times (작동 횟수에 따른 연소기 산화제 개폐밸브 작동 특성)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-83
    • /
    • 2020
  • The operating characteristics of a main oxidizer shut-off valve have been examined by life-cycle tests in which the valve operates as many times as is required at room and cryogenic temperatures. It is shown that there is no significant change of the operating characteristics in the course of the life-cycle tests. The critical pressures and principal forces, which represent the operating characteristics, differ at each operating time by less than about 3%. These qualified operating characteristics of the valve are expected to play an indispensible role in the stable startup and shutdown of a liquid rocket engine.

Opening Characteristics of a Main Oxidizer Shut-off Valve at Different Valve Inlet Pressures (밸브 입구 압력 변화에 따른 연소기 산화제 개폐밸브 열림 특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.801-807
    • /
    • 2020
  • Opening characteristics of a main oxidizer shut-off valve at different valve inlet pressures have been experimentally investigated. The pilot pressure at the moment of the valve opening increases linearly with increasing the valve inlet pressure and the increased pilot pressure reduces the valve travel time. As the pilot pressure increases at the moment of valve opening, the time to start opening the valve is delayed resulting in increasing the valve opening time. With the increment of the valve inlet pressure, the valve opening time is mainly determined by the time required for the pilot pressure to start opening the valve. Therefore the design of a pilot gas supply system can readily control the valve inlet pressure at the valve opening as well as the amount of oxidizer supplied to a combustion chamber during the engine startup.

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

A Study on analysis between pressure-drop and cavitation diminution with ball valve (볼 밸브 압력강하와 공동현상감소에 대한 연구)

  • Gu, Bon-Chan;Gi, Jun-U;Lee, Do-Hyeong
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.393-397
    • /
    • 2013
  • 관내의 유량을 제어하는 볼 밸브(ball valve)는 개폐각도(opening degree)가 커짐에 따라 출구에서 유속이 증가하고 밸브(valve)의 입 출구 간 압력강하(pressure drop)가 증가한다. 출구에서의 압력이 작동유체의 포화증기압보다 낮아질 때 공동현상(cavitation)이 발생한다. 관내에서의 공동현상은 배관시스템의 진동 및 소음, 부식 등에 있어서 악영향을 미칠 수 있으므로 설계에 매우 중요한 요소이다. 버터플라이 밸브를 비롯한 다른 밸브에서는 공동현상감소에 대한 연구가 많이 이루어졌다. 이에 본 연구에서는 볼 밸브 내 유동 특성(characteristic of flow)과 볼 밸브의 입출구간 압력강하를 줄이는 연구를 수행하였다. 개폐 각도와 그에 따른 압력강하와의 관계를 Edison_전산열유체를 사용하여 분석하고 공동현상을 감소시킨 볼 밸브의 설계를 제시 하였다.

  • PDF

Study for the Development of a Main Oxidizer Shut-off Valve for Liquid Rocket Engines (발사체 연소기용 산화제 개폐밸브의 핵심요소 기술 개발)

  • Kim, Dohyung;Hong, Moongeun;Park, Jaesung;Lee, Soo Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.113-119
    • /
    • 2013
  • A main oxidizer shut-off valve (MOV) controls the supply of cryogenic liquid oxygen to the combustion chamber of liquid rocket engines by on/off operations. The main subjects to be introduced are not only the valve transient response during valve on/off procedures but also the characteristics of pneumatic and seat/poppet parts as core technologies in the development of the MOV, which is expected to be adopted for the Korea Space Launch Vehicle II. It is shown that the analytical prediction of the transient valve travel is in good agreement with experimental results. Friction and elastic forces on the valve moving part are quantitatively evaluated by structural analysis.

Flow Rate Control System Design for the Industrial Valve (산업용 밸브의 유량제어 시스템 설계)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.387-392
    • /
    • 2020
  • This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.