• Title/Summary/Keyword: 배치형상

Search Result 337, Processing Time 0.021 seconds

Local Buckling in Steel Box Girder Bridge with Lifting and Lowering Support Method (지점 상승 하강 공법에 의한 강상자형교의 국부좌굴)

  • Koo, Min Se;Jeong, Jae Woon;Na, Gwi Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 2003
  • The lifting and lowering supports method makes up for the weak points in the classical method and provides makes construction economical effect to construction. The application of pre-compression to continuous steel box girder bridges makes it possible to reduce the amount of steel, the height of girders and consequently, the cost consequentlyof the bridges' construction by through the process of concrete filling- up and the lifting-lowering of the inner supports. The lifting and lowering supports method is apt to cause local buckling in the lower flange and web plates by due to the process of the lifting of the inner supports. Therefore iln this study, therefore, the possibility of local buckling could be decreased, in consideration of the lifting force and the buckling strength of stiffened plates, by increasing the number of longitudinal stiffeners and the installation of extended longitudinal stiffeners on the lower flange and the web plates in the range of positive moment.

Theoretical Evaluation of the Post Tensioning Effect in Continuous Slabs (연속 슬래브의 포스트 텐셔닝 보강에 대한 이론적 분석)

  • Kim, Chang-Hyuk;Kim, Kang-Su;Kim, Sang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.105-116
    • /
    • 2009
  • Reinforced concrete (RC) structures have been most widely used because of their good economic efficiency. However, it is very weak in tensile stresses and difficult to control deflection due to the heavy self-weight of concrete. On the other hand, it is generally known that prestressed concrete structures can be the most effective to overcome the demerits of RC structures by using various tendon lay-out and its amount. In the prestressed concrete members, the inflection points of tendons should be placed effectively for the deflection control and the moment reduction. Therefore, in this study, the equations of tendon profiles are derived in terms of polynomials that satisfy essential conditions of tendon geometries such as inflection points and natural curved shapes of tendons placed in continuous members, from which vertical components of prestressing forces can be also calculated. The derived high order polynomial expression for the distributed shape of the upward and downward forces was transformed to an simplified equivalent uniform vertical force in order to improve the applicability in the calculation of member deflection. The influences of vertical forces by tendons to deflection and moment in a continuous slab were also considered depending on the distance from column face to the location of tendons. The applicability of the proposed method was examined by an example of deflection calculation for the cases of slabs with and without tendons, and the efficiency of deflection control by tendons was also quantitatively estimated.

An Experimental Study for Bond Characteristics of Deformed Bar Embedded in Donut Type Biaxial Hollow Slab (도넛형 이방향 중공슬래브의 부착특성에 관한 실험적 연구)

  • Chung, Joo-Hong;Kang, Sung-Hoon;Lee, Seung-Chang;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.155-163
    • /
    • 2013
  • This study investigated the bond characteristics of embedded deformed steel bar in donut type biaxial hollow slabs. The donut type hollow sphere make concrete inner cover formed between steel bar and hollow sphere due to the hollow shape and arrangement. Generally, inner cover was thinner than outer cover, and some part of donut type biaxial hollow slab has smaller inner cover thickness than $2.5d_b$. It was affected to the bond condition of deformed bar. Furthermore, inner cover thickness changes along the longitudinal deformed bar due to hollow shape. Therefore, donut type hollow slab was divided 3 regions according to the hollow shape such as insufficient region, transition region, sufficient region. Pull-out test were performed to find out the effect of bond condition by the region. Main parameters are inner cover thickness, embedded length and bond location. Bond characteristics of donut type biaxial hollow slab were confirmed through comparison of bond stress-slip relationship, maximum bond strength and bond stress distribution of each regions. And the calculation method of bond strength of donut type biaxial hollow slab was suggested based on the test results.

Numerical analysis for heat transfer and pressure drop characteristics of (다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석)

  • Hou, Rong-Rong;Park, Hyeong-Seon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.367-375
    • /
    • 2014
  • In numbers of kinds of heat exchanger, the shell-tube heat exchanger is the most commonly used type of heat exchanger in the industry field. In order to improve the thermal performance of the heat exchanger, this study was analyzed heat transfer characteristics according to arrangement of baffle and direction of baffle and bump phase of baffle about shell-tube heat exchanger using appropriate SST (Shear Stress Transport) turbulence model for flow separation and boundary layer analysis. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature of shell side was constantly 344 K and the variation of the water flow rate was 6, 12, 18 and 24 l/min. As the result of analysis, zigzag baffle arrangement enhances heat transfer rate and pressure drop. Furthermore, in the direction of the baffle, heat transfer rate is more improved with vertical type and angle $45^{\circ}$ type than existing type, and pressure drop was little difference. Also, the bump shape of baffle surface contributes to heat transfer rate and pressure drop improvement due to the increased heat transfer area. Through analysis results, we knew that the increase of the heat transfer was influenced by flow separation, fluid residual time, contact area with the tube, flow rate, swirl and so on.

Development of Terrestrial Photogrammetric Technique for Structure Monitoring (구조물 monitoring을 위한 지상사진측량기법의 개발)

  • Han, Seung Hee;Kang, Joon Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.151-160
    • /
    • 1994
  • Recently, terrestrial photogrammetry has been applied effectively to data acquisition in GIS and to monitoring precise machinery for simulation test. Because 3-D coordinates of many object points can be quickly measured with constant accuracy and easy modeling by this method. In this study, the composition concerned with multi-camera system which simultaneously analyzes structure from multi-station using various cameras was developed. The errors of results were analyzed to investigate the accuracy of the system, error of unknown points and control points, convergent and strip adjustment for optimal network design also. As results of this study, the efficiency of multi-camera system developed here was proved through application to monitoring the entire area of the precise model ship. We could also acquire 3-dimensional coordinates with good accuracy by arranging pass points. Therefore, possibility of measurement of instantaneous deformation as well as precision analysis of structures can be suggested.

  • PDF

Design of Experiments for Optimization of Helicopter Flight Tests (헬리콥터 비행시험 최적화를 위한 실험계획법의 적용)

  • Byun, Jai-Hyun;Lee, Gun-Myung;Kim, Se-Hee
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.113-124
    • /
    • 2014
  • In developing an aircraft, configuration determination and requirement proofing depend on flight test results. Since the flight tests require much time and high cost, systematic flight test planning and analysis are needed to reduce cost and development time. This paper presents a desirability function approach to present an integrative measure of vibration levels at important positions and suggests a fractional factorial design which is one of the experimental design methods to help perform systematic flight tests. A method to perform flight tests in stages is also suggested to further reduce the number of flight tests.

Flashover Characteristics of the Horizontal Air Gaps Caused by Combustion Flames (연소화염에 의한 수평배치 공기갭의 섬락전압 특성)

  • 김인식;김이국;김충년;지승욱;이상우;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • In this paper, characteristics of the ac and dc flashover voltage in the horizontal air gap of a needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrode. In order to examine the flashover phenomena and the corona inception voltages caused by flame we measured the voltage and current waveforms when the corona and the flashover was occurred. We also observed, as increasing the applied voltages, the deflection or fluctuation phenomena in the shape of flames caused by the corona wind and the coulomb's force. As the results of an experimental investigation, we found that the reduction of flashover voltages, in comparison with the no-flame case, are 62.7[%] for k=1.0, 34.2[%] for h=5[cm], 27.3[%] for h=7[cm] and 21.4[%] for h=9[cm] when ac voltage is applied.

Three Dimensional Analysis of the Whole Interior-Surface of Structures by Multiple Close-Range Photogrammetry (다중근접사진측량에 의한 구조물 내부전면의 3차원 해석)

  • 이진덕;강준묵
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.11 no.1
    • /
    • pp.7-18
    • /
    • 1993
  • In analyzing whole surface of non-topographic objects, the design of multi-station photogrammetric network must involve a number of questions such as geometric configuration of exposure stations, imaging geometry, control point configuration or weight allowance of adjustments. Above all, the surveying of the interior of narrow longitudinal structures needs the design of special photogrammetric network. The main objective of this paper is to suggest the schemes for solving difficult problems attendant upon whole inside-surface analysis of structure and to improve the accuracy and reliability of final measurements. For it, the multi-station exposure network suitable to shape and size of the inside of the structure was designed. Then three dimensional data were acquired by bundle adjustments derived from multi-station photos and the effects of network design factors on accuracy of measurements were contemplated. Also, the algorithm for detection of blunders was developed here is expected to lead to improvement of the reliability of photogrammetric solutions.

  • PDF

Model Tests on the Reinforcement Effect of Unattached Strips to the Cantilever Retaining Wall (비정착 띠보강재의 역T형 옹벽 보강효과에 관한 모형실험)

  • Han, Gyeong-Je;Kim, Un-Yeong;Kim, Myeong-Mo
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.31-40
    • /
    • 1998
  • To verify the reinforcing effect of the strips which are inserted in the backfill, but not connected to the face wall, model tests are executed. As the reinforcing effect is expected to reduce the active thrust acting on the retaining wall, test programmes included the measurements of the thrust. As a result. it is ascertained that the active thrusts are reduced by as much as 50%. Besides, efficient arrangement and the optimum length of the strips are verified. And the the number of reinforcing strips are increased, are close to the Rankine's hypothesis.

  • PDF

Numerical Analysis for Three-Dimensional Tsunami Force Acting on Multi-Onshore Structures (육상구조물군에 작용하는 지진해일파력의 3차원수치해석)

  • Lee, Kwang Ho;Ha, Sun Wook;Lee, Kui Seop;Kim, Do Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2B
    • /
    • pp.175-185
    • /
    • 2011
  • This study investigates tsunami force acting on a group of onshore structures numerically by using three-dimensional one-field model for immiscible multi-phase flows, which is based on Navier-Stokes solver. In particular, we studied on the characteristics of tsunami with respect to the arrangement of onshore structures and the distance from seawall trough numerical experiments. For validation of the numerical method used in this study to calculate tsunami force, numerical results for tsunami force on the structures in coastal area are compared with available experimental data. Furthermore, a detail study on the efficiency of the numerical method is performed for the estimation of tsunami force based on the hydrostatic and hydrodynamic methods in which the numerical results are used. The obtained results are compared to the previous experimental one and design criteria. Considering both experimental results and numerical analysis results, semi-empirical formula by regression analysis is proposed. As a result, it was confirmed that the numerical analysis is effective to estimate on tsunami force acting on onshore structures.