• Title/Summary/Keyword: 배출관리기준

Search Result 289, Processing Time 0.028 seconds

Effects of Adsorption and Decomposition on the Removal of Total Organic Carbon (TOC) in Oil Wastewater by Cellulose-based Pseudo Graphene and Persulfate (셀룰로오스 기반 유사-그래핀과 과황산염에 의한 압연류 폐수내 총유기탄소(TOC) 흡착 및 분해효과 연구)

  • Song-I Kim;Ji-Young Shin;Kyung-Chul Park;Jae-Kyu Yang;Dong-Su Kim
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.3
    • /
    • pp.5-18
    • /
    • 2024
  • Chemical oxygen demand (COD), an organic material measurement index, has a limit to the management of the total amount of all organic materials including non-degradable organic materials due to low oxidation rate. So total organic carbon (TOC) that can measure organic materials more accurately is introduced and used as a measurement index. Several environmental companies including company A in Gyeonggi-do dilute raw wastewater first and then treats it with chemicals. And an activated carbon is used at the rear stage to treat total organic carbon even though various treatment processes can be applied to reduce TOC in wastewater. There are some problems such as use of a lot of diluting water and generation of an excessive amount of sludge, so it is urgent to come up with an alternative plan. Therefore, in this study, an application experiment was conducted on two different methods for improving the TOC reduction efficiency of waste water from Company A. The first method is the evaluation of the substitution potential of powered activated carbon(PAC), an adsorbent currently used, by manufacturing cellulose-based graphene like carbon (CGLC). This first study showed that CGLC had about 10% higher TOC adsorption efficiency than commercial PAC, showing the possibility of being applied as an alternative adsorbent for PAC in water treatment sites. The second method relates to the removal of TOC by sulfate radials produced by persulfate (PS) activation. Two activation methods were applied: using CGLC and PAC as carbon-based catalyst and using the high temperature of wastewater for PS activation. As a result of using PAC and CGLC as PS activation materials, the TOC removal rate was lower than the adsorption amount of TOC by CGLC and PAC due to excessive chlorine ions present in the real wastewater. However, as a result of using the high water temperature (55~60℃) of the field wastewater for PS activation, it showed a much greater TOC removal efficiency than PAC alone, CGLC alone, and using a carbon-based catalyst for PS activation. When PS was injected more than 0.5%, it showed a TOC removal efficiency of 95% or more within 24 hr. In addition, when PS was injected more than 0.3%, the TOC concentration could be lowered to less than 75 ppm, which is the wastewater discharge standard applied to company A. When these results were summarized, raw wastewater of high temperature can be treated with a simple process of only adding of PS and discharged by treating TOC below the wastewater discharge standard applied to company A.

A Study on Problems and Improvement of Home-help Services of Long-term Care Insurance (노인장기요양보험 재가서비스의 문제점과 개선방안)

  • Lee, Jun Woo;Jin, Hee
    • 한국노년학
    • /
    • v.29 no.1
    • /
    • pp.149-175
    • /
    • 2009
  • The purpose of this research is to analyze the overall problems at the moment of October 2008, and then to find the improvements of home-help services of the Long-Term Care Insurance(LTCI), which has been revealed many problems since it was released in July 2008. The research uses the literature survey which analyzes 2nd-hand materials studied by other people already, and survey research was executed from active social workers in the area of LTCI. Based on the policy analysis framework of Gilbert and Specht, all the data are analyzed in the scopes of client·benefit(service)·finance·transferring system. This research has found the problems in each scope of home-help services of the LTCI. Firstly, the client system has some problems in mismatching between registered and service clients, estimating client number, and judging service levels. Secondly, the service system reveals deficiency in professionality of social workers, service quality lowering by loose qualification criteria on workers, non-reasonable limitation of service time available, and the same fare system applied to visiting-help service in spite of different levels. Thirdly, in financing system, clients need to pay additional money to get extra services such as meal, hair cutting, bathing etc., due to government financial support stopped, some organizations have to reduce services and replace full-time workers to part-time ones, which makes the service quality worse. Lastly, in the transferring system, the management system for service quality is not well prepared. There are too much competion because of allowing too many home-help service organizations and care worker academies. The suggestions that this research has found to improve the policy are as follows. ① It is desirable to make the registered clients the service ones as many as possible in the long term perspective. ② The LTCI organization requires more workers and higher professionality. ③ Many elderly people who are not eligible now require connection system to be more served. ④ Management system and service manual for care worker are to be developed. ⑤ Laws related to the service contents and process should be modified, the proportion of client charge needs to adjust. ⑥ Home-help service organization licensed by the LTCI needs to be financially supported publicly. ⑦ Monitoring system to home-help service organization needs to be strengthened. ⑧ Evaluation tools to home-help service organization and workers is required. ⑨ Specification to open the home-help service organization needs to be more strict.

Human Health Risk, Environmental and Economic Assessment Based on Multimedia Fugacity Model for Determination of Best Available Technology (BAT) for VOC Reduction in Industrial Complex (산업단지 VOC 저감 최적가용기법(BAT) 선정을 위한 다매체 거동모델 기반 인체위해성·환경성·경제성 평가)

  • Kim, Yelin;Rhee, Gahee;Heo, Sungku;Nam, Kijeon;Li, Qian;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.325-345
    • /
    • 2020
  • Determination of Best available technology (BAT) was suggested to reduce volatile organic compounds (VOCs) in a petrochemical industrial complex, by conducting human health risk, environmental, and economic assessment based on multimedia fugacity model. Fate and distribution of benzene, toluene, ethylbenzene, and xylene (BTEX) was predicted by the multimedia fugacity model, which represent VOCs emitted from the industrial complex in U-city. Media-integrated human health risk assessment and sensitivity analysis were conducted to predict the human health risk of BTEX and identify the critical variable which has adverse effects on human health. Besides, the environmental and economic assessment was conducted to determine the BAT for VOCs reduction. It is concluded that BTEX highly remained in soil media (60%, 61%, 64% and 63%), and xylene has remained as the highest proportion of BTEX in each environment media. From the candidates of BAT, the absorption was excluded due to its high human health risk. Moreover, it is identified that the half-life and exposure coefficient of each exposure route are highly correlated with human health risk by sensitivity analysis. In last, considering environmental and economic assessment, the regenerative thermal oxidation, the regenerative catalytic oxidation, the bio-filtration, the UV oxidation, and the activated carbon adsorption were determined as BAT for reducing VOCs in the petrochemical industrial complex. The suggested BAT determination methodology based on the media-integrated approach can contribute to the application of BAT into the workplace to efficiently manage the discharge facilities and operate an integrated environmental management system.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Development of Economic Analysis Indicators and Case Scenario Analysis for Decision-making support for Off-Site Construction Utilization of Apartment Houses (OSC 활용 의사결정 지원을 위한 경제성 분석 지표 개발 및 사례 시나리오 분석 - 공동주택 PC공법을 중심으로 -)

  • Yun, Won-Gun;Bae, Byung-Yun;Shin, Eun-Young;Kang, Tai-Kyung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.6
    • /
    • pp.24-35
    • /
    • 2023
  • Recently, the Ministry of Land, Infrastructure and Transport presented the '6th Construction Technology Promotion Basic Plan' and 'Smart Construction Revitalization Plan (2022.7.20)'. Off-Site Construction (OSC), which involves construction and production of PC (Precast Concrete) and Modular, etc., has advantages in shortening the construction period, reducing costs, improving quality, reducing construction waste, and reducing safety accidents. However, the construction cost is high compared to the traditional RC construction method, which has hindered its utilization and spread. In this study, OSC utilization was improved. An economic analysis indicator and methodology that can support decision-making in the planning and design stages for multi-unit housing were proposed. The factors used in the economic analysis of OSC (based on the PC method) of apartment houses were reviewed. As for the indicators used in the cost and benefit section, 'Construction Period', 'Disaster Occurrence', 'Waste Generation', and 'Greenhouse gas Emission', which reflect the technical advantages of OSC, were derived. In addition, a scenario analysis was conducted based on actual apartment housing case data for the presented economic analysis indicators and benefit calculation standards. The level of benefit that offsets the difference between the existing RC construction method and the construction cost was reviewed. In future studies, it will be necessary to conduct additional case studies to apply the measurement criteria for detailed indicators and supplement the benefit indicators.

Control Measures for Air Pollutant Emissions from In-Use Light-Duty Diesel Vehicles Regarding their Emission Control Technologies (배출허용기준 대응기술을 고려한 국내 소형 경유 운행차의 대기오염물질 관리 방안)

  • Lee, Taewoo;Park, Hana;Park, Junhong;Jeon, Sangzin;Kim, Jeongsoo;Choi, Kwangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.327-338
    • /
    • 2014
  • The objective of this study is to enhance the effectiveness of Korean Inspection and Maintenance (I/M) program. Three main tasks are: to measure pollutant emissions of in-use light-duty diesel vehicles (LDVs); to evaluate the validity of existing smoke control scheme for low-smoke-emitting vehicles, which have diesel particulate filters, DPF, to meet stringent Euro-5 emission limits; and to assess the necessity and the benefit of $NO_x$ inspection, which is not involved in current I/M program. We measured second-by-second smoke, particulate and gaseous emissions of 27 LDVs using opacity smoke meter, photo-acoustic soot sensor, and portable emissions measurement system, respectively, under the Korean I/M test driving cycle, KD-147. We find that the DPF plays a key role in controlling soot, which can be considered as black carbon contained in particulate matter. Thus, from an I/M perspective, we believe smoke inspection strategies for Euro-5 diesel vehicles should be more focused on the capability of detecting DPF malfunctions or failures, in order to keep DPF properly functional. Fleet averaged distance-specific $NO_x$ emissions are consistently higher than corresponding emission limits, and the values are similar among pre-Euro-3, Euro-3, and Euro-4 vehicle fleets. These findings indicate that the $NO_x$ inspection should be incorporated into current I/M program in order to manage urban $NO_x$ emissions. This research allows the Korean I/M program keep pace with developments in vehicle technologies, as well as the increased emphasis on $NO_x$ with respect to air quality and human health.

Health and environmental risk assesment of air pollutants in Gyeongju and its vicinities(I) (경주 주변지역 대기오염물질의 보건.환경 위해성 평가(I))

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Park, Tong-So;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3740-3747
    • /
    • 2009
  • To protect the citizens' health of Gyeongju and to secure basic data for the assessment of health and environmental risk, distribution characteristics of meteorological elements were investigated and numerical simulation of wind field using RAMS model was carried out. In addition, measurement and analysis of air pollutants, forecasting the behavior air pollutants using ISC-AEROMOD view, and health and environmental risk-influenced zones were defined through managing air polluting materials to prevent health damage and property damage. According to the survey results of air pollution in Gyeongju and surroundings, average annual concentration of air pollutants in Gyeongju was slightly lower than that in Pohang and Ulsan areas, but concentration of particulate matters and nitrogen dioxide at Gyeongju Station Square and Yonggang Crossing were sometimes higher than that in Pohang and Ulsan areas. Results of the modeling of moving and diffusion of air pollutants that affect citizens' health showed that parts of the 1st through 4th industrial complexes together with POSCO were included in particulate matters and sulfur dioxide influenced areas in Pohang Steel Complex area, and that Haedo-dong, Sangdae-dong, Jecheol-dong and Jangheung-dong in Pohangnam-gu represented locally worsened air quality due to a quantity of air pollutant emission from dense steel industries and large scale industrial facilities.

Chemical Properties Distributions of Commercial Organic By-product Fertilizers (시판 부산물비료의 화학성 분포)

  • Lee, Chang-Ho;Yoon, Young-Man;Ok, Yong-Sik;Lim, Soo-Kil;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Agricultural recycling of livestock wastes by composting has lots of beneficial effects on crop production and soil fertility. Most of composts are made from pig manure and water content controller such as saw dust, bark, rice hulls etc. by aerobic processing. But the insufficient supply of saw dust, bark etc. cause the indiscreet use of industrial waste having heavy metals and toxic synthetic chemicals. This research investigated the present quality status of organic by-product fertilizers, and suggested the way of quality interpretation under the statistical approaches based on median, mean and weighted average value. Since the data of one hundred of samples for heavy metal contents (Cd, Pb, Cu, and Cr) and OM/N showed extremely left-skewed distribution, the median was more useful than the mean in representing the characteristics of distribiition for each items. The weighted average value will be a useful index for the quality based on the total amount of producing.

An Empirical Study of Hot Water Supply Patterns and Peak Time in Apartment Housing with District Heating System (공동주택의 급탕부하 지속시간 및 부하 패턴에 관한 실증연구)

  • Kim, Sung-Min;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.435-443
    • /
    • 2012
  • The combination of space shortage and the high population density concentrated in urban areas of South Korea has resulted in the growth of large-scale high-rise residential complexes, naturally affecting water and hot water usage patterns as well. But the current designs for water and hot water supply in South Korea rely mostly on international design standards and data calculated on site due to the severe shortage of basic data in relation to actual use, which result in the frequent problem of the under-or over-design of water and hot water supply. The following study measures the hot water supplier's conditions and the user's heat usage to realize the amount of time required for hot water supply load generation and the pattern of actual use in order to create basic data for effective hot water supply facility design and maintenance.

Designing the Promotion Policy of Korea ESCO Industry through the Examination of Foreign Country Exercises (해외사례 조사를 통한 국내 ESCO 산업 활성화 방안)

  • Min, Eunju;Kim, Myeongrok;Nam, Kitae;Kang, Mingoo;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.26 no.1
    • /
    • pp.103-121
    • /
    • 2017
  • The domestic ESCO project was introduced in 1992 as one of the energy efficiency improvement programs. In recent energy market, the changes in the market conditions such as smart grid, renewable energy, and the importance of demand response became important issues. As the diversified business models are required, examples of overseas exercises are examined. Business areas in Europe or the US where the ESCO industry has been active include measures to improve the efficiency of energy facilities in all areas, ranging from energy supply facilities and energy services to end users. This type of ESCO overseas business model can be classified into various types such as project execution method, supplier demand management, financing method, climate change and emission rights, new and renewable energy, and other criteria. In this study, we propose to adopt IEC (Integrated Energy Contracting) contract method in domestic ESCO market for additional business models. Current convention of listing the specific individual business types being allowed by regulation turned out to be obstacles to the revitalization of the related market. In order to achieve the goal of energy conservation, it is recommended, instead, to revise the current funding guidelines to be a negative system.