• Title/Summary/Keyword: 배제유량

Search Result 106, Processing Time 0.024 seconds

A Method of Estimating the Volume of Exploitable Groundwater Considering Minimum Desirable Streamflow (최소하천유출량을 고려한 지하수 개발가능량 산정방안)

  • Chung, Il-Moon;Lee, Jeongwoo
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.375-380
    • /
    • 2013
  • The concept of safe yield places an emphasis on balancing groundwater withdrawal with groundwater recharge but ignores naturally occurring groundwater discharge. Because streams and their alluvial aquifers are closely linked in terms of water supply and water quality, to be properly understood and managed they must be considered together. Therefore, some districts in Kansas have reevaluated their safe-yield policies to account for natural groundwater discharge and stream-aquifer interactions by amending their safe-yield regulations to include a portion of baseflow as the minimum desirable streamflow (MDS). This study proposes a modified safe-yield policy in which the drought flow is chosen as the MDS. Baseflow separation was conducted from streamflow hydrograph and the results are presented as a flow-duration curve. The exploitable groundwater can be determined by subtracting MDS from the cumulative baseflow. This method was tested in the Musimcheon watershed, which was validated for streamflow using the SWAT-K model. The annually averaged exploitable groundwater in the whole watershed was estimated to be 86 mm. The exploitable groundwater amounts were also estimated for each subwatershed in the Musimcheon watershed.

황토의 인흘착 성능평가

  • 허영오;손지호
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.65-66
    • /
    • 1997
  • 우리나라의 대부분 하천과 인공댐의 경우 조류발생에 기여하는 영양염은 질소, 인 그리고 규소 등인데 특히 인이 생산제한 인자로 작용하고 있다. 따라서 인을 적절히 제거할 경우에는 조류 발생에 의한 수질의 악화와 수이용의 저해요인을 배제할 수 있어 이에 대한 연구가 많이 진행되어 왔다. 지금까지와 연구는 인의 화학적 응집 침전법, 생물학적 처리법에 대하여 수행되어 왔으나 설비자금, 운영비, 운전기술, 슬러지 생성 그리고 제거효율 등에서 만족스런 결과가 도출되지 못하여 현장 적용을 하지 못하고 있는 실정이다. 이러한 현실을 감안하여 우리의 자연 환경에서 쉽게 자할 수 있는 황토를 모재로하여 Al3-과 Fe3-, Ca2-을 적절히 배합하여, 주로 인을 선택적으로 제거하 고자 개발된 황토의 흡착능력 그리고 흡착 메카니즘에 대한 기본적인 연구를 하고자 (1) 등온흡착실험을 통하여 흡착용량을 평가하고 (2) 흡착제거속도를 평 가하였고 (3)파과시간 및 흡착특성을 파악하기 위해 column 흡착실험을 하였다 또한 (4) 황토내의 Al3-, Fe3-과 Ca2- 등이 인의 화학적 흡착에 기여하는 정도를 파악하여 흡착메카니즘을 규명하고자 하였다. 먼저 흡착용량실험을 위하여 PO3-4-P 농도 3ppm의 용액 200mf에 황토 0.2g, 0.5g, 1.0g, 2.0g을 각각 투여한 후 충분한 흡착평형이 일어나게 24시간 동 안 130rpm으로 $25^{\circ}C$ 등온반웅조에서 저어주어 흡착평형에 도달하면 상등액을 GF/C Filter로 여과한 후, 여액에 대해 PO3-4-P의 농도를 Ascrobic he건법으로 측정한 결파, Freundlich 등온흡착식에 의하면 K값은 17.34와 16.28이었으며 1/n 값은 1.32와 1.42로 인흡착 성능이 뛰어난 것으로 평가되었다. 둘째, 흡착속도 실험은 PO3-4-P 농도 1.5ppm의 용액 2f에 259의 황토를 투여하고 충분한 혼합이 일어날 수 있도록 170rpm으로 교반하면서 시간별 용액 의 농도 변화를 측정한 결과, 0.45mg/g/m교의 속도로 15분만에 94.3%의 인 제거 효율을 보였다. 셋째, 직경 12mm의 glass column에 황토를 209 채우고 1.5ppm의 PO34P 용액을 2.Sne11in의 유량으로 통수 시킨 후, 시간에 따른 농도 변화를 측정한 결과, 원수 농도의 50%에 해당하는 파과점까지 약 70시간 만에 도달하였다. 넷째, Al3-, Fe3-과 Ca2- 등이 화학적 흡착에 기여하는 정도를 파악하기 위 하여 황토 2g에 대하여 Hieltijes and Lijklema 방법에 의해 Adsorbed-p, Nonapatite inorganic-P(NAI-P), Apatite-p, Organic-P로 구분하여 분석하고, 총인(Total Phosphorus)을 Standard Methods에 따라 Persulfate digestion후 0.45 m membrane 여지 여과하여 여액에 대해 PO3-4-P의 농도를 Ascorbic Acid 법으로 측정한 결과, NAI-P가 가장 큰 비율을 차지하였고, 부원료로 첨가된 금속 양이온 중 Fe3-이온이 흡착에 기여하는 정도가 가장 큰 것으로 평가되었다.

  • PDF

Feasibility of Pyrophyllite Ceramic Membrane for Wastewater Treatment and Membrane Fouling (국내산 납석기반 세라믹 멤브레인 수처리 적용 가능성 평가 및 파울링 현상관찰)

  • Park, Eunyoung;Jang, Hoseok;Choi, Nakcheol;Lee, Sungjae;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.205-211
    • /
    • 2016
  • Performance of pyrophyllite-based ceramic membranes newly developed were investigated. Membrane fouling caused by microbial suspensions taken from a full-scaled MBR system at domestic wastewater treatment plant was observed at different airflow rate and distance between each membrane. For the pyrophyllite support, pore size was about $1.0{\mu}m$, but surface coating with $Al_2O_3$ solution decreased the pore size with the reduction of the pure water permeability. With the MLSS taken from the full-scaled MBR system (6 g/L), the fouling rate was decreased by increasing airflow rate under $20L/m^2{\cdot}hr$ of setpoint flux. However, the effectiveness of the airflow rate on the fouling control depends strongly upon the gap between each membrane. At fixed airflow rate, the fouling rate was decreased by increasing the gap between each pyrophyllite membrane. Nevertheless, further increasing the membrane distance from 3.5 to 5.4 cm resulted in higher fouling rate. Similar result was observed with the $Al_2O_3$ coated-pyrophyllite membrane. Nevertheless, the fouling rate was lower with the coated membrane than that observed with the uncoated pyrophyllite support. Regardless of surface coating, the suspended solids were removed almost completely and the surface coating on the pyrophyllite support improved organic rejection with PEG solution (MW : 8000 kDa) tested.

A Study on Price Competitiveness for LNG Bunkering in the Busan Port (부산항의 LNG 벙커링 가격 경쟁력 확보 방안)

  • KIM, Geun-Sub
    • Journal of Korea Port Economic Association
    • /
    • v.32 no.1
    • /
    • pp.123-133
    • /
    • 2016
  • LNG(Liquefied Natural Gas) bunkering has become an important issue with the enforcement of environment regulations in shipping industry required by the International Maritime Organization (IMO). With increased attention on LNG bunkering, many studies that focus on safety, regulation, demand forecasting, and the feasibility of LNG fueled ships have been carried out. However, most of the existing research has not included considerations of the price of LNG bunkering and its competitiveness. This paper, therefore, suggests ways to increase price competitiveness in the LNG bunkering market in the Busan Port. This paper analyzes the LNG bunkering supply mechanism by investigating various LNG bunkering terminal business in the LNG supply market. Factors that determine LNG bunkering price and its elasticity are also identified. Market players who want to operate LNG bunkering terminals in the Busan Port should introduce a merchandising trade method that is able to exclude the "Korea premium" in order to increase price competitiveness. This paper also suggests adoptable strategies such as the use of TPS (Terminal to Ship via Pipeline) type of bunkering service and the importance of location for minimizing initial investment cost.

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF