• Title/Summary/Keyword: 배제용적

Search Result 17, Processing Time 0.03 seconds

Experimental Study on the Depth-Variations of Confluence Area in Small Urban Channel (도시 소하천 합류부 수심변화에 대한 실험연구)

  • 심기오;이길춘
    • Water for future
    • /
    • v.28 no.3
    • /
    • pp.197-204
    • /
    • 1995
  • The runoff from an urban catchment is increased because of the gravitation of the population towards cities. For this reason, water level increment in confluence area makes it impossible to drain internal water and thus produces flood out in upstream areas. In this study, flow variations of main channel are measured which is caused by combining storm sewer into main channel in small watershed. Depth increment in main stream is analyzed due to flowrate and slope in main channel and flowrate, slope is getting steeper, and also due to low flowrate in main stream and high flowrate in tributrary channel. For the degree of confluence, depth ratio decreases when the degree is getting small. As mentioned above, main factors influencing the depth ratio increment of confluence channel are in the order of the degree of confluence, and the flowrate of tributary channel and main channel.

  • PDF

Effects of Various Thermal Treatments on Physicochemical Properties of Wheat Bran (밀기울에 대한 열처리가 이화학적 특성에 미치는 영향)

  • Hwang, Jae-Kwan;Kim, Chong-Tai;Cho, Sung-Ja;Kim, Chul-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.394-403
    • /
    • 1995
  • Various thermal treatments such as toasting, roasting, drum drying, autoclaving+drum drying, microwaving+drum drying and extrusion were attempted to investigate their effects on chemical composition (proximate composition, Klason lignin, neutral sugar, uronic acid, starch, free sugar, dietary fiber, phytic acid, etc) and functional properties (water solubility index, water absorption index, water holding capacity, oil holding capacity, bulk density, swelling, etc) of wheat bran. Thermal treatments on wheat bran increased soluble dietary fiber (SDF) content from 2.7% (raw sample) to 4.6% (toasted), 4.5% (roasted), 4.6% (drum dried), 5.2% (autoclaved), 3.7% (microwaved), 5.6% (extruded). In contrast, total dietary fiber (TDF) content remained nearly constant regardless of thermal treatments, reflecting the concomitant decrease in insoluble dietary fiber (IDF). It was also found that water holding capacity (WHC) increased $20{\sim}75%$ due to thermal treatments employed in this research. Both bulk density and swelling were not directly relevant to WHC, but thier multiplication exhibited good correlation $(R^2=0.94)$ with WHC. Scanning elctron microscopy (SEM) exhibited that structure of raw wheat bran was significantly modified, whose degree and shape well reflected the types of thermal treatments.

  • PDF

Temporal and Spatial Analysis of Extended Sewer Surcharge on Anyangcheon Watershed Using PCSWMM (PCSWMM 모형을 이용한 안양천 유역에서 내수침수의 시간적.공간적 해석)

  • Lee, Kil-Seong;Kim, Sung-Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1150-1155
    • /
    • 2006
  • 대부분의 도시지역은 불투수면적 비율이 상당히 높은 특징으로 인한 유출용적 및 첨두유출량의 증가와 외수위보다 낮은 지반고의 지형학적 특징으로 인한 내수배제의 불량으로, 저지대의 침수위험도가 상당히 높다. 이러한 이유로, 빈도별 설계홍수량을 산정하여 침수위험지역을 파악하고 관리하는 공간적인 치수관리가 이루어지고 있지만, 효율적인 치수관리를 위해서는 공간적인 측면뿐 아니라, 침수위험지역 내 침수발생의 시간적인 측면도 고려하는 것이 필요하다. 본 연구에서는 침수위험지역 내 내수침수발생에 대하여 공간적.시간적으로 살펴보고, 내수침수발생 위험지역 및 우선관리지역을 선정하였다. 대상유역으로는 안양천 유역에서 대부분의 침수가 발생하는 서울시에 포함된 안양천 하류유역으로 하였다. 서울시에 포함된 안양천 하류지역에서 내수침수발생의 주원인으로는 외수위보다 낮은 지반고와 배수계통의 통수능력 부족으로 나타나고 있어, 이들 지역의 침수위험지역을 파악하기 위해 하도 및 관거의 유출해석에 우수한 SWMM 모형의 EXTRAN block을 이용하여 모의를 실시하고 맨홀이 월류되는 지역을 내수침수 위험지역으로 선정하였다. 각 빈도별 지속시간별 모의결과, 목감천 하류부의 고척 1동, 신월 1동, 화곡 2동, 도림천과 봉천천, 대방천이 만나는 구로동, 대림 1동, 대방동에서 침수가 발생하기 시작하였다. 이들 지역은 또한 10년에서 30년 빈도별 모의에서도 모두 침수위험이 높은 지역으로 선정되어, 우선관리지역으로 선정하였다. 우선관리지역의 선정은 홍수예.경보 측면에서는 주민의 신속한 대피와 같은 홍수대처능력과 치수관리측면에서는 소요되는 자원의 효율적 배분을 기대할 수 있을 것으로 판단된다. 대상으로 홍수범람모의시스템을 구축하여 분석결과를 피해지역주민 및 관련기관 실무자들에게 제공함으로써 시간과 공간에 구애받지 않는 재해관리와 신속한 재해 상황 대처가 가능해 질 것으로 사료된다.는 또 다른 형태의 주제도라고 볼 수 있으며, 이를 구축하기 위해서는 자료변환 및 가공이 필요하다. 즉, 각 상습침수지구에 필요한 지형도는 국립지리원에서 제작된 1:5,000 수치지형도가 있으나 이는 자료가 방대하고 상습침수지구에 필요하지 않은 자료들을 많이 포함하고 있으므로 상습침수지구의 데이터를 인터넷을 통해 서비스하기 위해서는 많은 불필요한 레이어의 삭제, 서비스 속도를 고려한 데이터의 일반화작업, 지도의 축소.확대 등 자료제공 방식에 따른 작업 그리고 가시성을 고려한 심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상

  • PDF

Determination of Hydraulic Parameters in Unconfined Sandy Aquifer in a Laboratory Scale (실내 자유면 사질 대수층의 수리상수 결정)

  • 김정석;김동주
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 1999
  • Oil leaked from underwound storage tanks and leachate from sanitary landfills have been known as contaminant sources of the high-quality groundwater resources. The mobility of contaminants in the aquifer largely depends on the groundwater flow and the determination of associated hydraulic parameters is essential for a proper remediation of contaminated grnundwater. This study aimed at determining an optimum set of hydraulic parameters for an unconfined sandy aquifer of a laboratory scale through comparison of various methods. Results showed that the specific yield obtained from gravity drainage experiment was an average of 0.20 with minor variations in aquifer depths. and the permeabilities obtained from Dupuit approximation and slug test gave similar values of 5.33 cm/min and 5.85 cm/min but the constant head method gave 0.17 cm/min, which is much ion than the other methods. This experimental evidence reveals that the permeability of the unconfined sandy aquifer could be accurately determined by Dupuit assumption or slug tut rather than by constant head method conducted for a disturbed separate soil column.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Soil Water and Nutrient Movement Model Under Different Soil Water Conditions -I. Determination of Retardation and Hydrodynamic Dispersion Coefficient of Solute of an Unsaturated Sandy Loam Soil (토양수분(土壤水分) 분포(分布)에 따른 토양내(土壤內) 양수분(養水分) 이동(移動) 모형(模型) -I. 불포화(不飽和) 토양(土壤)에서 용질(溶質)의 이동지연(移動遲延)과 수리동적(水理動的) 분산계수(分散係數)의 측정(測定))

  • Jung, Yeong-Sang;Woo, Deog-Ki;Lim, Hyung-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.1
    • /
    • pp.8-14
    • /
    • 1990
  • Retardation and hydrodynamic dispersion coefficient necessary for model of water and solute movement in a soil were determined for horizontal soil column with different initial soil water conditions. The soil columns were compacted with sandy loam soil. The bulk density was $1,350+50kg/m^3$, and initial water contents were 0.05, 0.08 and 0.14. Advancement of 0.05% $CaSO_4$ solution was used as the standard and advancements of 0.5% KCl, $CaCl_2$ and $KH_2PO_4$ were compared. Retardation of non-reactive $Cl^-$ was related with the initial soil water content, ${\theta}n$, as ${\theta}/({\theta}-{\theta}n)$, and anion exclusion was ignored. Retardations of active $K^+$, $Ca^{{+}{+}}$ and $H_2PO_4{^-}$ were related as 1/(R+1) $^*{\theta}/({\theta}-{\theta}n)$, in which R was retardation coefficient. Measured R was 0.64 for $K^+$, 0.80 for $Ca^{{+}{+}}$ and 2.6 for $H_2PO_4{^-}$, respectively. Calculated R using Langmuir adsorption isotherm showed fair degree of applicability. Soil water diffusivity, $D({\theta}),m^2/sec$, calculated for different initial water content showed unique function as $$log(D({\theta}))=13.448{\theta}-9.288$$ Hydrodynamic dispersion coefficient of $Cl^-$ above soil water content 0.36 was similar to soil water diffusivity and decreased to near self diffusion coefficient at soil water content near 0.2. Those of $K^+$, $Ca^{{+}{+}}$ $H_2PO_4{^-}$ at soil water content of 0.38 were $5.5{\times}10^{-6}$, $2.4{\times}10^{-6}$ and $7.1{\times}10^{-7}m^2/sec$ and decreased rapidly with decreasing soil water content lower than 0.36.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF