• Title/Summary/Keyword: 배수펌프

Search Result 160, Processing Time 0.025 seconds

Runoff simulation for operation of small urban storm water pumping station under heavy storm rainfall conditions (집중호우 시 도시 소유역 배수펌프장 운영을 위한 강우유출모의)

  • Gil, Kyung-Ik;Han, Jong-Ok;Kim, Sung-Geun;Lee, Chang-No;Kim, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In this study, runoff simulation was carried out in order to derive operational improvement of small urban storm water pumping station under heavy storm rainfall conditions. The flood inflow hydrograph of Guri city heavy storm in July, 2001 was successfully simulated by HEC-HMS, a GIS-based runoff simulation model. For the runoff simulation, ArcView, as an effective GIS tool, was used to provide input data of the model such as land use data, soil distribution data and SCS runoff curve number.

  • PDF

An Evaluation of Heating Performance of the Heat Pump System Using Wasted Heat from Thermal Effluent for Greenhouse Facilities in Jeju (발전소 온배수 폐열을 이용한 제주 시설온실 냉난방용 열펌프 시스템의 난방성능 평가)

  • Moon, Sungbu;Hyun, Myung-Taek;Heo, Jaehyeok;Lee, Dong-Won;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 3 km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. The preoperational tests proved that the water temperature drop through the pipeline transporting extracted heat was less than $2^{\circ}C$. The COP (coefficient of performance) of the heat pump was higher than 4.0, and hot water with the maximum temperature of $50^{\circ}C$ could be supplied to greenhouse facilities by utilizing wasted heat from thermal effluent.

PSA 기법을 이용한 가압경수로 부분충수운전 안전성 향상방안

  • 박진희;이윤환
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.604-609
    • /
    • 1996
  • 원자력 발전소 부분 충수운전 중에 발생할 수 있는 정지냉각기능 상실사고인 과배수 사건에 대한 확률론적 안전성 평가를 수행하였다. 본 분석의 주된 목적은 과배수로 인한 정지냉각기능 상실사건에 대하여 노심손상 빈도를 계산하고 안전성 향상방안을 도출하는데 있다. 과배수 사건은 초기 부분 충수운전중 발생하는 것으로 가정하였으며 이 때의 발전소 배열(Plant Configuration)은 영광 3,4호기의 운전절차서 및 발전소 운전경험을 근거로 결정하여. 현재 운전상태에 대한 확률론적 안전성평가를 수행하였다. 분석결과 인간오류가 노심손상빈도에 가장크게 기여하는 인자로 나타났으며 인간오류를 줄 일수 있는 대체냉각 절차를 선정하여 재분석을 수행하였다. 고려된 대체냉각 수단은 피동적인 잔열제거 방법인 열규응축냉각(Reflux Cooling)과 정지냉각펌프의 대체계통으로 격납용기 살수펌프를 사용하는 경우의 두가지이다. 본 분석에서는 두가지 대체냉각수단을 모두 채택하는 것으로 가정하여 대체냉각 사용에 따른 효과를 비교하였는데 노심손상 빈도가 1/1000로 감소 하였다. 따라서 절차서 개정에 의한 대체 냉각수단확보는 부분 충수운전중 발전소 안전성 향상에 매우 효과가 큰 것으로 나타났다.

  • PDF

A Safety Evaluation of Detention Reservoirs at Seoul by New Pumping Criteria (우수배제 펌프의 조작기준에 따른 서울시 유수지의 안전검토)

  • Lee, Won Hwan;Park, Sang Deog;Shim, Jae Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.141-150
    • /
    • 1992
  • Rapid change of urban area become a serious cause of disaster in existing drainage systems, and the practical alternatives in that situations are needed. The purpose of this study is to evaluate safety, one of drainage systems, detention reservoir and pumping station by new pumping criteria. New drainage pumping criteria, divided into two parts (rising limb and falling limb), which used in reservoir routing, shows more efficient flood prevention effect than existing criteria (based on the reservoir water level). To obtain the optimal range of flood prevention, sensitivity analysis of each inflow v.s. pumping capacity is tested. As a results, using 10 year design rainfall, 60% of detention reservoir and drainage pumping stations in Seoul are safe. In this results, there must be a fundamental and powerful counterplans to prevent inland flooding in Seoul metropolitan area.

  • PDF

빗물배수 펌프장의 부하특성을 고려한 변압기용량 설계

  • 곽노진
    • Electric Engineers Magazine
    • /
    • v.210 no.2
    • /
    • pp.28-35
    • /
    • 2000
  • 빗물펌프장은 지역침수로 인한 피해를 방지 또는 최소화시키는 것을 목적으로 한 비상 시설물이며 재해대책 시설로서 그 중요성이 커지고 있다. 여기에 그 시스템 운영에 있어서 중추적인 역할을 담당하는 기계, 전기설비 시스템의 최적화, 효율 화는 필수적이며 설비 자체의 안전과 시스템 운전안전 확보가 우선되므로 과잉설비로 계획되어 경제적인 시스템 구축이 간과될 소지가 많다.

  • PDF

Design Optimization of Two-Way Pump Casing through Flow Analysis (양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계)

  • Kim, Dong-Hwi;Noh, Yoojeong;Lim, O-Kaung;Choi, Eun-Ho;Choi, Ju Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • A two-way pump can reduce costs by draining and circulating water out and into the drum of the washing machine using a single motor whereas a conventional one-way pump uses two motors for doing the same function. However, when the water is drained through the drainage outlet in the two-way pump casing, a backward or inhalation flow occurs and the water flows to the circulation outlet. Likewise, when the water is circulated, the backward flow or inhalation makes the water flow to the drainage outlet. In this study, design optimization of the two-way pump casing is performed to maximize its performance while improving backward flow and inhalation occurring inside of the pump casing. For this, design variables of the pump casing that mainly affect the performance of the pump such as flow rate and torque of the motor were selected through the analysis of mean. Using response surface models for the performances, the ratio of the flow rate to the torque was maximized with satisfying the constraints for the back flow and inhalation through design optimization.

Assessment of Drainage Facilities Ability Using SWMM (SWMM을 이용한 관망 및 펌프시설의 배수능력 평가)

  • Kim, Jae-Pyo;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.266-266
    • /
    • 2011
  • 최근 전 세계적으로 국지적 집중호우의 강도 및 발생빈도가 증가하고 있고, 이로 인한 인명 및 재산피해가 증가하고 있는 추세이다. 특히 도시유역의 침수는 설계빈도를 초과한 강우가 짧은 지속기간에 집중되었을 때 관로의 통수능력을 초과하게 되어 발생하거나, 주변 하천의 수위상승으로 인한 배수효과로 인해 발생된다. 따라서 기상이변으로 인한 침수피해를 체계적이고 종합적으로 방지할 수 있는 수방대책 수립이 필요하다. 본 연구에서는 서울시 주요 침수유역의 관망 및 펌프장의 수방 대응능력 및 수준을 정량적으로 평가하고자 한다. 이에 서울시의 과거 침수사례를 조사하여 상습침수 구역에 대한 침수 해석범위를 결정하였고 내수침수모의를 위한 적정 홍수해석모형으로 SWMM모형을 선정하였다 또한 수문 기상자료, 지형정보자료, 수방시설 현황 자료 등 각종 기초자료를 조사 및 구축하고 과거 큰 호우사상을 대상으로 관망과 펌프장의 시설능력을 평가를 수행하였다. 평가 결과 대부분 우수관망의 통수능력 한계로 인한 침수가 발생한 것으로 확인되었다. 이러한 분석을 통해 관망 및 펌프장 시설의 개선, 확충 및 설계 기준을 새롭게 제시하고 유역별 홍수취약정도에 따른 수방기준 차별화를 통해 침수피해를 방지할수 있는 수방대책 기준을 제시할 수 있을 것으로 사료된다.

  • PDF