• Title/Summary/Keyword: 배관 설계 시스템

Search Result 166, Processing Time 0.023 seconds

A Development of Offshore plant Piping Process Monitoring System Based on 3D CAD Model (3D CAD 모델 기반 해양플랜트 배관 공정 모니터링 시스템 개발)

  • Kim, Hyun-Cheol;Lee, Gyu-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.58-65
    • /
    • 2020
  • 3D Models of offshore plant piping materials designed by 3D CAD systems are provided to the production processes in the form of 2D piping drawings and 2D piping installation drawings. In addition to the standard engineering information, the purchasing, procurement, manufacturing, installation, and inspection of raw materials are managed systematically in an integrated process control system. The existing integrated process management system can help reduce the processing time by managing the flow and progress of resources systematically, but it does not include 3D design model information. Hence, it is difficult to understand complicated pipe structures before installing the pipe. In addition, when design changes or immediate design modifications are required, it is difficult to find related data or exchange information quickly with each other. To solve this problem, an offshore plant-piping process-monitoring system was developed based on a 3D model. The 3D model-based piping monitoring system is based on Visual Studio 2017 C# and UNITY3D so that the piping-process work information can be linked to the 3D CAD model in real time. In addition, the 3D model could check the progress of the pipe installation process, such as block, size, and material, and the progress of functional inspection items, such as cleaning, hydraulic inspection, and pneumatic inspection.

A Development of Program on the Hydraulic Calculation in Sprinkler System Based on the Piping Network Analysis Method (배관망 해석 방법을 이용한 스프링클러 시스템의 수리계산 프로그램 개발)

  • 송철강;이명호;강계명
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.24-29
    • /
    • 2002
  • The purpose of this study is developing the computer program for hydraulic design sprinkler systems have performed the means for the general use of network analysis method. The computer program is based on the theoretical concepts of the related Hazen-Williams equations, a modified Bernoulli equations, and the Hardy Cross method of pipe network analysis. Looped piping calculations are solved by using either the Hardy Cross method or the other iteration methods. While the other methods are solved using simultaneous equations, the Hardy Cross method is concerned with one loop at a time using reiterative process. Due to its simplicity the Hardy Cross method will be the primary method described in this thesis. The purpose of this study is to develope hydraulic calculation program by using algorithm for network analysis method. The development of computer program for the hydraulic design of sprinkler systems will perform the means in the performance-based sprinkler system design.

Safety Assessment of By-product Gas Piping after Design Change (부생가스 연료배관의 설계변경에 따른 안전성 평가)

  • Yoon, Kee Bong;Nguyen, Van Giang;Nguyen, Tuan Son;Jeong, Seong Yong;Lee, Joo Young;Kim, Ji Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.50-58
    • /
    • 2013
  • Various process piping usually carries out high flammable and explosible gas under high pressure and high temperature. Due to frequent change of design and structure it becomes more complicated and compactly located. The safety management level is relatively low since it is considered as simply designed component. In this study a safety assessment procedure is proposed for complicated piping system around a mixing drum in which natural gas and by-product gases were mixed. According to ASME code, pipe stress analysis was conducted for determining design margin at some key locations of the piping. These high stress locations can be used as major inspection points for managing the pipe integrity. Sensitivity analysis with outside temperature of the pipe and support constraint condition. Possible effect of hydroen gas to the pipe steel during the previous use of the by-product gas was also discussed.

배수설비에 사용되는 기기의 특성

  • 권용일
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.10
    • /
    • pp.31-35
    • /
    • 2003
  • 배수설비시스템에 적용되는 각종 기기들의 특징 및 통기관의 선정 방법을 미국의 ASPE code에 제시되어 있는 내용을 중심으로 소개하고자 한다. 건물 내에서 발생하는 오수 및 배수는 항상 건물 외부로 잘 배출시켜야 한다. 이러한 배수시스템은 원활한 배수가 수행되어야 하도록 수평배수관은 적합한 구배를 주어야 하며, 부지경계선 밖에 설치된 공공하수도와 체결하여 한다. 오수배관은 지상에 노출시키거나 사설정화조를 체류하지 않고 우수로에 직접 배출할 수 없다. 배수설비를 설계할 때의 문제점은, 배수배관 및 통기관을 선정시 선정된 관경이 최적화되었는지 평가하는데 있다. 즉, 현존하는 건축물의 배수시스템에서 문제점이 발생하지 않는다고 설계된 배수배관경 및 통기관경이 최적화된 것으로 평가하기에는 어려움이 있다고 판단된다.(중략)

  • PDF

Research of detect of the object in stainless pipe using the magnetic inductance (자기인덕턴스를 이용한 Stainless Steel 배관 내 이물질 검사에 대한 연구)

  • Joo, Gun-June;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.179-181
    • /
    • 2006
  • 각 원자력 발전소에서는 정밀성, 안전성을 확인하는 검사의 중요성을 인식하여 LPMS(Loose Part Monitoring System)을 사용하여 사고 징후를 조기에 감지하여 이에 대한 예방조치를 가능케 함으로써 설계기준 사고 발생을 사전에 방지할 수 있게 한다. 또한 이 기술은 신호 측정 및 분석 등의 기반기술 개발을 통하여 건전성 감시 기술의 신뢰성을 향상 시키고 있다. LPMS(Loose Part Monitoring System)기술은 재료, 기기, 구조물 등의 성질과 내부조직을 변화시키거나 파괴하지 않고, 배관내부에 흐르는 금속 파편들을 찾아내어 정밀성, 안전성, 신뢰성을 확보하기 위하여 검사기술이 적용되고 있다. 그러나 이 방법은 배관내의 이물질의 충격이 발생해야 감지가 가능하고, 이물질의 모양이나 사이즈를 확인하기에는 어려움이 있다. 따라서 본 논문에서는 배관외부에서 자기장을 인가하여, 배관내의 이물질에 변화하는 자기장을 홀센서로 측정하여 기존의 LPMS 방식을 보완하는 시스템을 개발하기 위해, 배관에 필요한 자기장 발생장치를 설계하고, 이물질을 검출하기 위한 검출 감도향상에 대해 연구하였다.

  • PDF

A Study on System Stress Analysis of High Temperature Plant Piping with Expansion Joints and Load Hangers (신축이음과 하중행거가 함께 설치된 고온플랜트 배관계의 시스템응력 해석 연구)

  • Park, Do Jun;Yu, Jong Min;Han, Seung Yeon;Yoon, Kee Bong;Kim, Ji Yoon
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.116-124
    • /
    • 2014
  • In the plants operated under high temperature condition, piping system load analysis is often performed to prevent accidents caused by thermal deformation and also to locate inspection prioritity points of the piping system. In this study, piping system stress analysis was performed for a pipe system between the reactors in a process plant. The piping system includes typically installed hangers and expansion joints. In order to evaluate the effects of structural components such as hangers and expansion joints, the case for the expansion joint or the hanger under abnormal operation is considered. By comparison anlaysis results of piping system during normal operation and abnormal operation, the role of each pipe components are studied.

A Representation of Product Model for the Piping System Based on the Object_Oriented Paradigm (객체지향기술을 이용한 배관시스템 모델의 표현)

  • Jong-Kap Lee;No-Sang Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.19-30
    • /
    • 1994
  • The modeling of a product data is becomming more and more important in engineering environment, especially for the development of CAD/CAM system as a basis of computer integrated manufacturing system. Model is a formalized representation of the real world, and modeling is the task to identify, abstract, and formalize the product information into an unambiguous representation. In this study, the piping system, one of typical product of ship outfitting system, is modeled. The STEP idea is followed to provide a common mechanism to represent the product information throughout the life-cycle, and the object oriented paradigm is used in the analysis and design of the model. The definitions given within this model are independent of the specific application domain so that the same methodology can be used for other purpose.

  • PDF

건물의 배수 및 통기시스템: 배관 내부압력의 능동적인 제어

  • Gormly, Michael;Swaffield, John. A.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.9
    • /
    • pp.41-51
    • /
    • 2010
  • 건물의 배수 및 통기시스템에서 나타나는 현상중에 확실한 내용이 아직 밝혀지지 않은 부분이 몇 가지 남아 있다. 이것은 19세기 말엽의 근대 위생공학의 시작 단계에서부터 잘 알려진 사실이다. 건물의 배수 및 통기시스템 운용에 대한 내용은 일반 공학과 특정 유체역학의 범위 내에서 가장 잘 이해할 수 있다. 건물의 배수 및 통기시스템의 운영에 종사했던 초기의 기술진들은 이러한 점을 잘 알고 있었으며 유체역학에 적합하게 응용한 많은 사례를 확인할 수 있었다. 제2차 세계대전이 끝나고 이에 대한 많은 연구가 진행되어 왔으며 특히 유럽에서 시작된 전후 재건 붐을 통해 배수 및 통기시스템의 설계에 좀 더 효율적인 접근이 진척되게 되었다. 이러한 배수시스템의 중심에는 배수관 내부의 오염된 공기가 배수구 또는 위생기구를 통하여 주거 공간으로 유입되는 것을 방지하는 트랩(Water Trap)이 있다. 배수트랩의 주요 기능인 봉수는 일반적으로 깊이가 40 mm에서 50 mm 정도로 위생기구의 종류에 따라 봉수의 깊이는 다소 차이가 있다. 배수관내 공기의 흐름이 중요한 것처럼 트랩의 봉수 메커니즘이 중요하기 때문에 이 메커니즘을 소홀히 여긴다면 안전한 배수시스템의 운영을 기대하기는 어렵다. 배수관 내의 공기의 흐름은 배수에 의해 유입되거나 또는 배출된다. 배수관에서 내부 압력의 불규칙한 변화로 인하여 야기되는 불안정한 배수의 흐름은 트랩의 봉수를 파괴하고 나아가 주거공간으로 오염된 공기가 새어 나갈 수 있는 통로를 제공하게 된다. 관내압력의 천이는 이로 인한 문제가 발생할 가능성이 있는 위치에 그 압력을 완화할 수 있는 장치를 설계단계에 반영하여 적용함으로써 제어할 수 있다. 건물 내부에 상당한 길이의 통기배관을 설치하는 것은 배관의 마찰손실로 인하여 천이 현상을 효과적으로 제어할 수 있는 확실한 방법이 되지는 못한다. 그렇지만 통기밸브를 설치하는 것과 같이 배수관 내로 공기를 공급해주는 유입구를 건물 내부에 분산 설치하는 것이 효율적인 통기방식이 될 수 있고, 정압 천이로 인한 위험을 줄여줄 수 있다. 통기밸브는 정압 발생의 원인이 되지 않으며 단지 정압에 반응하여 더욱 기밀하게 닫히며, 약화된 압력파를 반사할 뿐이다. 고층 건물에서 배수입상관과 평행하게 설치된 통기입상관(Parallel Vent Pipe)의 경우 극히 일부분의 정압 천이 현상을 완화할 수 있다. (통기 배관의 직경이 배수 입상배관과 동일한 경우 대략 1/3 정도임), 그러므로 정압의 천이로 인한 압력 파동은 배수 시스템의 나머지 부분을 통해 전파되어 배수 트랩에 영향을 미치게 된다. 정압의 천이가 예상되는 위치에 정압천이 완화 장치(Positive Air Pressure Transient Alleviation Device)를 사용하면 배관 내부압력의 급격한 상승을 방지하여 연결된 트랩의 봉수를 보호할 수 있다. 이렇게 되면 순간적으로 발생하는 배관내 압력의 급등 현상을 90% 정도까지 완화 시킬 수 있다. 경험적으로 배수시스템에서 배관이 완전하게 막혀 과도한 정압이 발생하는 경우는 거의 없다. 이러한 경우에는 가장 낮은 위치에 있는 배수 트랩의 봉수가 깨지면서 자연스럽게 배수시스템의 압력이 해소되게 된다. 이러한 사례는 통기 방식과 상관없이 발생할 수 있다. 실제와 유사한 시뮬레이션을 통하여 통기 밸브(Air Admittance Valves)는 전면 통기 시스템 (Fully Vented System)에서 최소한 트랩의 봉수 보호용으로 적합한 것이 확인 되었다. 어떤 경우 에는 고층 건물에 더욱 적합하다는 것을 확인할 수 있었다. 부압 해소용으로 통기밸브를 이용하고 정압완화용으로 정압 완화장치(PAPAs: Positive Air Pressure Transient Attenuators)를 사용하는 전면적 능동 제어시스템(Fully Engineered Designed Active Control System)이 사용자에게 육안으로는 확인하지 못하는 기능을 보장하면서 배수 시스템의 안전과 효율성에 대한 효과적인 방법을 제공하고 있다.

  • PDF

A numerical study on deformation characteristics of bracket for fire pipe system (소방 배관용 브라켓의 변형특성에 관한 수치적 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.312-318
    • /
    • 2010
  • 본 연구에서는 배관계에 가해진 압력으로 인하여 변형된 배관에 의하여 영향을 받는 브라켓에 대하여 여러 가지 형상으로 모델링하여 유한요소해석을 통하여 브라켓의 형상변화가 변형특성에 미치는 영향을 고찰 하였고, 배관시스템의 브라켓의 강도 안전성을 확보하기 위하여 산업공학에서 쓰였던 다구찌방법을 도입하여 최적화 설계를 하는 것이 본 연구의 목적이다.

  • PDF

Optimum positioning of friction support for vibration reduction in piping system (배관 진동저감 마찰 지지대 최적 위치 선정)

  • Jaeseok, Heo;Yong Hoon, Jang;Seunghun, Baek
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.680-690
    • /
    • 2022
  • Vibrations in the pipe system trigger fatigue-related issues and lead to fatal other problems caused by pipe damage. There are numerous studies to analyze and reduce the cause of pipe vibration, among which a small number of studies are being conducted on pipe vibration reduction using friction supports. The study of friction supports, however, focused only on predicting and evaluating the performance of the friction supports and seldomly considered the design perspective of the install location of the supports. Therefore, this study intends to suggest the optimization process for finding the best installation region of friction support to attenuate the vibration of entire piping system. The optimal position of the friction support is predicted only by linear analysis to guarantee optimization efficiency in the design process. The designed friction support location is verified by time domain analysis.