• Title/Summary/Keyword: 배관시스템

Search Result 577, Processing Time 0.028 seconds

Development of Ultrasonic Testing System for Piping Welds (배관 용접부 초음파검사 시스템 개발)

  • Choi, Sung-Nam;Kim, Hyung-Nam;Yoo, Hyun-Ju;Cho, Hyun-Jun;Hwang, Won-Gul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.331-338
    • /
    • 2008
  • Ultrasonic testing for welds is widely used to ensure the integrity of facilities in NPPs. Automated ultrasonic testing(AUT) is more consistent than the manual ultrasonic testing(MUT). It can scan welded parts, examines the scanned images, and saves the results as data files. AUT in NPPs is making use of commercial systems, and there has been some difficulties in calibration of the system. An AUT system is developed. It comprises of pulser/receiver, scanner and a control program(SonicWizard). The performance demonstration for piping welds in NPPs and the piping wall thickness measurement on site were conducted to verify this system. The test results of the ultrasonic testing system developed is satisfactory and effective.

Testbed Control and Data Acquisition System for Pipeline Pinhole simulation (배관 파공 모사를 위한 테스트베드 제어 및 데이터 취득 시스템)

  • Jeong, Jae-Ho;Jeong, In-kyu;Jeong, Chang-Hong;Kim, Jaeyoung;Im, Kichang;Kim, Jong-Myon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.29-30
    • /
    • 2018
  • 전 세계적으로 급증하고 있는 에너지 수요로 인해 오일, 가스 등의 에너지 생산 매체를 운송 할 수 있는 수송 수단인 배관에 대한 수요도 증가하고 있는 추세이다. 그러나 이러한 배관을 장시간 사용할 경우 노후화로 인해 발생되는 파공은 배관에 흐르는 유체 누설의 원인이 되고, 나아가서 경제 및 재난 피해를 야기할 수 있다. 따라서 다양한 배관 누설 검출 기술들이 개발되고 있는 추세이며, 이를 위해서는 신뢰성 있는 결함 모사 데이터의 확보가 매우 중요하다. 본 논문에서는 신뢰성 있는 데이터 수집을 위해 배관의 누설 상황을 모사 할 수 있는 테스트베드를 제어하고, 테스트베드에서 데이터를 안정적으로 취득할 수 있는 테스트베드 제어 및 데이터 취득 시스템을 제안한다.

  • PDF

Diagnosis of Pipe Structures using Impedance Measurement Sensor nodes (임피던스 측정 센서 노드를 이용한 배관 설비 진단)

  • Jang, In-Hwan;Jeong, Yeon-Wook;Song, Byung-Hun
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.367-369
    • /
    • 2009
  • 본 논문은 저전력 무선 임피던스 기반 구조물 건전성 감시 USN 시스템을 활용하여 electro-mechanical Impedance 센서의 일종인 PZT센서를 부착한 배관 구조물의 건전성을 진단하는 방법과 그 실험 결과에 대해 소개 한다. 기존에는 건설구조물에 가해지는 전기적인 입출력비에 해당하는 임피던스를 계측하기 위해서 비교적 고가의 대형 계측 장비가 필요로 했으며, 구조물에 설치된 센서를 계측장비에 연결하기 위한 유선의 케이블 작업 역시 추가로 필요했었다. 대형 배관 구조물의 경우에는 이러한 문제점 때문에 임피던스를 이용한 능동형 센서가 제대로 활용되지 못하고 있고 비정기적인 비파괴검사에만 국한되어 사용되어 왔다. USN기술은 저전력 소출력 무선통신을 통해 기존의 계측시스템과는 다른 상시모니터링의 장점을 가지고 있는 기술로서 최근 토목/건설 분야에서 적극적으로 활용이 되는 융합기술이다. 본 논문에서 구조물 건전성 감시 분야와 저전력 무선 계측 기술의 통합을 통해 얻어진 최적화된 배관 건전도 진단 센서 노드의 효율성을 정량적 실험 데이터를 통해 입증하고, 앞으로의 연구 방향에 대한 제안으로 끝을 맺는다.

  • PDF

A study on the principal cost of district heating transportation system related to low supply temperature (공급온도 저하에 따른 지역난방 배관망 기초비용에 관한 연구)

  • 김석순;정찬교;최기련
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.82-87
    • /
    • 1995
  • 국내 지역난방의 역사는 서구의 역사와 비교하여 짧기 때문에 아직 기술 도입의 의존도가 높고 설계에 있어서도 서구의 설계기준을 그대로 도입하여 지역난방 시스템을 운전하고 있다. 따라서 우리나라 실정에 맞는 시스템설계가 필요하다고 하겠다. 특히 열원시설과 수용가 시설사이에서 열을 운송하는 열운송시설, 즉 배관망(이후 배관망으로 칭한다.)에서의 공급 및 회수온도가 유럽의 대류난방방식에 따라 설계되어 높게 설정되어 있다. 공급 및 회수온도가 높다는 것은 열운송시 열손실이 많다는 것을 의미한다. 이에 이 연구에서는 일정 배관망 모델을 선정하여 공급 및 회수온도를 낮추어 운전할 때 발생되는 비용변화를 기초로 공급 및 회수온도 저하운전 가능성을 제시하고자 하였다. 그 결과 배관망에서 공급 및 회수온도를 동일 구배로 낮추는 것이 년간 총 비용을 감소시키므로, 운전온도의 저하가 가능함을 알 수 있었다.

  • PDF

The study of developing the freezing seal isolation method for the pre insulated heat transfer pipe (이중보온 열수송관에 대한 동결차수공법개발에 관한 연구)

  • You, Byounghee;Ahn, Changkoo;Kim, Woocheol;Shin, Ikho
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.105-112
    • /
    • 2017
  • A lot of piping systems have been used from nuclear power systems to water supply systems. The maintenance of the piping systems is needed to ensure proper operation of the piping systems. Failure of the large pipe systems especially such as KDHC(Korea District Heating Corporation) can be a matter directly related to the enterprise productivity and profitability. It can also lead to very important issues in promoting public safety and convenience. Therefore a method of quick and safety repairs have been emerged as the most important problem. In this study, freezing seal isolation method using liquid nitrogen cryogenic refrigerant was developed for the maintenance of a pre insulated heat transport pipe of KDHC with a diameter of 300 mm. In this study, by employing computational analysis techniques we performed the flow and heat transfer analysis for the targeted pre insulated heat transfer pipe and freezing seal jacket(ice-Plug) and have selected for optimal system. The detailed design model based on the results of the computational analysis finally was produced. A laboratory-scale test apparatus were designed and the freezing seal isolation self-test carried out. Also the performance assessment tests in the test bed of KDHC were carried out for on-site application.

Development of a Sensornetwork based Wireless NDT Service Model for High-pressurized Piping Wall Thinning Defect Inspections in a NPP (원전 고압배관 감육검사를 위한 센서네트워크 기반 무선 NDT 서비스 모델 개발)

  • Choi, Yoo-Rark;Lee, Jae-Cheol
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.469-471
    • /
    • 2008
  • 원자력발전소에는 매우 복잡하고 긴 배관 시스템이 작동되고 있다. 이 배관은 매우 높은 온도와 압력에 견디게 설계 및 제작 되었으나, 사용연수의 증가에 따라 배관이 깎이는 감육현상이 발생하며, 이로 인한 배관 파단 사고가 발생하고 있다. 이러한 감육현상은 배관의 곡관부에서 자주 발생하는데, 이를 감시하기 위하여 지금까지는 초음파를 이용한 배관 두께 측정을 해오고 있다. 그러나 이 검사 결과의 신뢰성이 없고, 유선 검사 방식을 채택함으로 인한 장비 설치 문제로 극히 일부 배관의 곡관부에 대한 감시만 수행되고 있는 문제가 있다. 본 논문에서는 펄스 와전류 기법과 일체형 소형 무선 센서를 이용하여 이러한 문제를 해결할 수 있는 방안을 제안한다.

  • PDF

A development of the gas pipeline risk prediction models (도시가스 배관 위험 예측 모델 개발)

  • Park, Giljoo;Kim, Young-Chan;Lee, ChangYeol;Jo, Young-do;Chung, Won Hee
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.360-361
    • /
    • 2017
  • 도시가스 배관의 안전을 위해 다양한 시스템이 가동되고 있지만 대부분 현장점검에 의존하는 한계점을 가지고 있다. 본 연구에서는 국내 도시가스 공급업체들 중 하나인 중부도시가스사의 실시간 배관운영 데이터를 분석해 배관의 위험을 예측한다. 배관의 압력, 출력전압, 출력전류, 방식전위, 전위값 데이터와 기타 도시가스 관련요인 데이터를 통합해 상관분석을 진행한다. 그리고 특정 공급권역의 실시간 배관 압력 데이터를 분석해 압력 수치를 예측한다. Random forest regression과 support vector regression(SVR) 알고리즘을 사용해 모델을 구성한 결과 배관 데이터의 시계열 정보를 추가한 데이터 셋과 random forest regression을 사용한 모델에서 가장 우수한 예측 성능을 보인다.

  • PDF

Radiometric Scanning System for the Inspection of the Pipeline (방사선을 이용한 배관 검사 시스템 제작)

  • Kim, Yong-Kyun;Hong, Seok-Boong;Chung, Chong-Eun;Park, Se-Hwan;Lee, Woo-Gyo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.164-168
    • /
    • 2003
  • Digital 방사선투과검사 시스템인 1차원 Radiometric scanning system을 개발하여 부식 및 침적물이 있는 배관의 두께평가에 적용하였다. 단일 방사성 동위원소에서 나오는 방사선을 선현으로 접속하여 시험체를 투과시킨 방사선을 BGO 검출기를 사용하여 측정하는 single source - single detector alignment system과 제어 프로그램을 개발하였다. 개발된 시스템의 성능을 GEANT4 프로그램을 사용하여 예측하였다. 그리고, 인공결함을 제작하여 넣은 시편과 두께 변화를 준 시편에 적용하여 실제 성능을 평가하였다. 방사성 동위원소를 이용하여 배관의 부식과 침적물에 의한 두께 변화에 대하여 실시간으로 필름을 사용하지 않고 평가할 수 있음을 확인하였다.

  • PDF

Development of temperature monitoring system of pressurizer surge tine thermal stratification (원전 원자로 냉각재 계통의 가압기 밀림배관 열성층 온도 감시 시스템 개발)

  • Ro, Jae-Hee;Kwon, Seok-Geon;Yi, Uk-Kun;Kim, Jung-Sun;Shon, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2501-2503
    • /
    • 2000
  • 본 연구는 윈자력발전소 원자로 냉각재 계통의 가압기 밀림배관내에서 서로 다른 온도의 유체가 밀도차에 의해 분리된 채 존재하는 열성층의 온도를 감시할 수 있는 시스템을 개발한다. 개발된 온도 감시 시스템은 국내원자력발전소 중 가장 오래된 고리원자력발전소 1호기의 수명연장과 관련하여 가압기 밀림배관의 열성층 온도를 측정하므로써 열성층화에 따른 배관의 건정성 여부를 평가하는데 사용한다.

  • PDF

업체탐방 - 국내 최대의 생산설비와 최고의 품질관리 시스템을 갖춘 배관자재 제조업체 두리화학 주식회사

  • 한국제품안전협회
    • Product Safety
    • /
    • s.246
    • /
    • pp.40-43
    • /
    • 2014
  • 두리화학(주)는 1974년 모체 공장인 대성화학을 창립한 이래 플라스틱 배관자재 생산 전문업체로 성장 발전해 왔다. 그동안 고객의 욕구를 충족시키고 고객 감동경영을 실현하기 위해 부단히 노력해 온 두리화학(주)는, 최근 공동주택 배관시스템의 최대 결점인 배수 소음 및 결로를 별도의 방음 및 보온 작업을 하지 않고도 배수 소음 및 결로를 획기적으로 줄일 수 있는 공법을 개발하여, 국내 유수의 건설 업체에 납품하여 뛰어난 성능을 인정받게 되었다. 동종업계에서 국내 최대의 생산 설비와 자동화 제조 공정을 갖추고 최고의 품질관리 시스템을 가동하여, 부적합품 발생방지에 주력하고 있으며 사후 관리에도 만전을 기하고 있다. 또한 두리화학(주)는 기업의 최대 목적인 이윤을 추구함에 있어 사회적 책임을 다하고 "고객감동경영"의 경영철학을 바탕으로 무한 경쟁시대의 21세기를 맞아, 항상 고객과 함께 연구하고 발전하는 기업으로 거듭날 것을 다짐했다.

  • PDF