• Title/Summary/Keyword: 방호시설

Search Result 214, Processing Time 0.031 seconds

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

사용후핵연료 중간저장(건식형태)시설의 구조 및 설비기준 개발

  • 김영상;이상국
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.247-252
    • /
    • 1996
  • 사용후핵연료 건식 중간저장시설은 설계수명기간 동안 방사능 차폐, 냉각, 보호 등과 같은 주요 기능이 확실히 보장되도록 설계 및 유지·관리되어야 한다. 이러한 주요 기능은 여러가지 설계하중 하에서 구조물의 거동을 정확히 파악한 결과를 설계에 반영함으로써 보장된다. 본 연구에서는 구조물의 건전성을 보장할 수 있는 기능적 측면과 구조적 측면에서 고려되어야 할 항목 및 내용을 국외에서 적용되고 있는 기술기준을 토대로 하고 풍하중, 홍수방호, 내진설계, 열하중해석, 철근콘크리트 및 강구조물, 기초지반과 같은 세부항목에 대한 해석 및 설계의 연구결과를 추가하여 국내 원자력법령과 시행령에 부합되는 사용후핵연료 건식중간저장시설의 구조 및 설비기준을 개발하였다.

  • PDF

A Study on the Establishment of Anti-Drone system for the Protection of National Important Facilities (국가중요시설 방호를 위한 안티드론 시스템 구축 방안 연구)

  • Hwang, Soon-phil;Kim, Doo-hwan
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.247-257
    • /
    • 2020
  • The Purpose of this study is to present effective Anti-Drone systems to protect national important facilities against drones that are illegally used by crime groups and terrorists with malicious intents. In order to accomplish the purpose of the study, technical and policy reports regarding Anti-Drone systems, open documents from manufacturers and various research papers are reviewed, and in-depth interviews with experts were conducted. Studies have shown that it is effective to overlay and mix different detection systems so that they can improve detection rates by supplementing each other's advantages and disadvantages, and that the means of incapacitation need to acquire flexibility by using both soft-kill and hard-kill methods in accordance with operational environment for the effective usage. In other words, the establishment of an illegal drone pre-management system, mixed and overlapping detection assets, determining appropriate countermeasures, and multiple distribution of means of incapacitation. The establishment of a protection system for important national facilities through the operation of overlapping and complex anti-drone systems is the most urgent task.

Performance Sensitivity of Flexible Barriers to Input Parameters (연성 방호구조물의 입력변수에 대한 동적 퍼포먼스 민감도 분석)

  • Yi, Gyu-Sei
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.13-20
    • /
    • 2010
  • To evaluate the performance of safety apparatus without the full scale crash test, the computer simulation is inevitable. But, to improve the accuracy of computer simulation, it is important to reasonably determine the input parameters in which the interaction of vehicle-guardrail-soil should be accounted for. This study is focused on how to enhance the reliance of the dynamic performance of guardrail obtained by computer simulation. Analyses were done on the sensitivity of output variables to the change of input parameters by using BARRIER VII of which the usefulness was proved on the barrier-vehicle impact analysis. Through the analyses important input parameters, which give sensitive effects to output of computer simulation, are found out, and methods to determine such parameters are suggested to improve the accuracy of simulation.

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

Evaluation of impact resistance of high performance fiber reinforced cementitious composites under high-speed projectile crash (고속 비상체 충돌에 대한 고성능 섬유보강 시멘트 복합체의 방호성능 평가)

  • Moon, Jae-Heum;Park, Jung-Jun;Park, Gi-Joon;Cho, Hyun-Woo;Kim, Sung-Wook;Lee, Jang-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4950-4959
    • /
    • 2015
  • The importance of public infrastructures' protection against crash or blast loads has been emerging issue as structures are becoming bigger and population densities in downtown cities are growing up. However, there exists no sufficient study which considers the developments of protective building materials, that are essential for protective design and construction. To assess the protection performance and the applicability as protective materials of high performance fiber reinforced cementitious composites(HPFRCC), this study performed the impact tests with 40 mm gas-gun propelled projectile crash machine. From this study, it has observed that both high compressive strength of cement matrix and fiber reinforcement are beneficial for the improvement of impact resistance.

Evaluation of Fracture Behaviours of Cementitious Composites by High-velocity Projectile Impact (고속 비상체 충격에 의한 시멘트 복합체의 파괴거동 평가)

  • Min, Ji-Young;Cho, Hyun-Woo;Lee, Jang-Hwa;Kim, Sung-Wook;Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.55-62
    • /
    • 2015
  • An importance of infrastructures' protection against crash or blast loading has been an emerging issue as structures are becoming much bigger and population densities in downtown are growing up. However, there exists no such a standard to evaluate the protection performance of construction material itself. Prior to building standards for protection assessment techniques, this study performed gas-gun propelled projectile impact tests with series of contact-type monitoring systems to investigate the applicability of each sensing type. Through the impact tests, failure modes and protection performances of both normal concrete and UHPC (Ultra High Performance Concrete) reinforced by steel fibers were also evaluated. The results showed that LVDT could be applicable for the impact test among contact-type sensors and UHPC with fibers had a remarkable potential to improve protection against impact loading.

Optimized Evaluation of Counter Drone System for Defending National Major Facilities through a Thinking Process of RMA (군사혁신(RMA) 사고과정을 적용한 국가중요시설 대드론체계 평가점검표 최적화)

  • Sang-Keun Cho;Ki-Won Kim;In-keun Son;Cook Rhie;Hyun-Ho Choi;Kang-Il Seo;Sang-Hyuk Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.789-793
    • /
    • 2023
  • Evalution of counter drone systems is conducted in order to designate plausible countermeasues against possible drone threats, assess the level of safety of national major facilities and derive complementary measures for detected weakness. Recently drone threats by North Korea have heavily impacted ROK(Republic of Korea) people and it has been stronly stressed to build efficient counter drone system for make the society protected and secured against drone threats. The researchers has conducted field investigations for some of national major facilites. There is, however, no standardized evaluation checklist, so we have proposed an evaluation checklist for counter drone systems though thinking process of RMA(Revolution in Military Affairs). This paper is to introduce the evaluation checklist for properly diagnosing each counter drone system.

TNT Explosion Demonstration and Computational Fluid Dynamics for Safety Verification of Protection Wall in Hydrogen Refueling Station (수소충전소 방호벽 안전성 검증을 위한 TNT 폭발실증 및 전산유동 해석)

  • Yun-Young Yang;Jae-Geun Jo;Woo-Il Park;Hyon Bin Na
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.102-109
    • /
    • 2023
  • In realizing a hydrogen society, it is important to secure the safety of the hydrogen refueling station, which is the facility where consumers can easily meet hydrogen. The hydrogen refueling station consists of compressed gas facilities that store high-pressure hydrogen, and there is a risk that the high-pressure compressed gas facility will rupture due to a fire explosion due to hydrogen leakage in the facility or the influence of surrounding fires. Accordingly, the Korea Gas Safety Corporation is making every effort to find out risk factors from the installation stage, reflect them in the design, and secure safety through legal inspection. In this study, a TNT explosion demonstration test using a protection wall was conducted to confirm the safety effect of the protection wall installed at the hydrogen refueling station, and the empirical test results were compared and verified using FLACS-CFD, a CFD program. As a result of the empirical test and CFD analysis, it was confirmed that the effect of reducing the explosion over-pressure at the rear end of the protection wall decreased from 50% to up to 90% depending on the location, but the effect decreased when it exceeded a certain distance. The results of the empirical test and computer analysis for verifying the safety of the protection wall will be used in proposals for optimizing the protection wall standards in the future.

Assessment of the Electromagnetic Pulse Shield Effectiveness of the Wave-guided Below Cutoff Filled with Water and Oil for Guaranteeing the Operational Sustainment of the Command Post (지휘소 작전지속성 보장을 위한 도파관의 전자기파 차폐성능 향상방안)

  • Yoon, Sangho;Son, Kiyoung;Kim, Suk Bong;Park, Young Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.579-584
    • /
    • 2013
  • The stable fueling and water supply should be prerequisites to guarantee the operational sustainment of military command post. Meanwhile, in terms of the operational sustainment, it is verified that the current wave-guided below cutoff (WBC) system cannot satisfy the requirement of control associated with water supply and fueling within the command post. In this study, as the dielectric substance can block electromagnetic pulse (EMP), it was tried to identify the shielding effectiveness of the multi WBCs filled with water and diesel for attenuating the EMP effect using experiment based on the MIL STD 188-125-1. According to the experimental results, used water in the experiment show the shielding effectiveness from around 640 MHz frequency because of minerals contained in the water. Furthermore, it was noted that EMP attenuating strength of the WBC filled with diesel was enlarged from around 1,680 MHz frequency. Resultingly, it could be concluded that it is enough to supply stable water and diesel through the multi WBC to block EMP within the military command post for guaranteeing the military operations sustainment.