• Title/Summary/Keyword: 방호성능

Search Result 235, Processing Time 0.025 seconds

A Trade Study of the Top Attack Smart Tank Ammunition (상부공격 전차 지능탄에 대한 상쇄연구)

  • Hong, Jong-Tae;Choe, Sang-Gyeong;Kim, Gi-Pyo
    • 시스템엔지니어링워크숍
    • /
    • s.6
    • /
    • pp.121-125
    • /
    • 2005
  • 전차탄의 철갑기술과 전차의 방호기술의 경쟁적인 연구개발로 성능이 지속적으로 발전되면서 전차방호면에서는 피탄되기전에 탄을 인식하여 파괴하는 능동파괴장치로,대전차 기술면에서는 취약한 전차의 상부를 발사후 망각개념의 지능탄으로 타격하는 기술로 발전되고 있다. 본 논문에서는 군사선진국들이 개발중인 전차포 지능찬의 특성을 조사하고 새로운 체계모델을 설정하여 비교상쇄연구를 수행하였으며, 향후 무기체계로의 가용성을 분석하였다.

  • PDF

Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space (화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2012
  • In restroom on high-rise building, exhaust system comprising the blower and duct is installed to discharge the odor and the water is suppled. Thus the restroom with fire and flame protection system may be used as refuge area in a fire situation. The study presents the smoke-proof system which operates such that the exhaust system to discharge the odor is converted to air supply system and appropriate pressure difference between the restroom and the accommodation is maintained. Also real-scale test facilities of smoke-proof system for refuge space using a restroom are installed on 5-story smoke control test building and experiments for evaluating the operational performance of smoke-proof system are carried out.

A Study on the ballistic impact resistance and dynamic failure behavior of aramid FRMLs by high velocity impact (고속충격에 의한 아라미드 섬유강화 금속적층재의 방탄성능 및 동적파손거동에 관한 연구)

  • 손세원;이두성;김동훈;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.527-532
    • /
    • 2000
  • The armor composite material targets such as aramid FRMLs with different type and ply number of face material and different type of back-up material, were studied to determine ballistic impact resistance and dynamic failure behavior during ballistic impact. Ballistic impact resistance is determined by $\textrm{V}_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Also dynamic failure behaviors are respectfully observed that result from $\textrm{V}_{50}$ tests. $\textrm{V}_{50}$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during high velocity impact tests. As a result, ballistic impact resistance of anodized Al 5052-H34 alloy(2 ply) is better than that of anodized Al 5052-H34 alloy(1 ply), but Titanium alloy showed the similar ballistic impact resistance. In the face material, ballistic impact resistance of titanium alloy is better than that of anodized Al 5052-H34 alloy. In the back-up material, ballistic impact resistance of T750 type aramid fiber is better than that of CT709 type aramid fiber.

  • PDF

Comparison of SE Evaluation Methods for HEMP Shelters (HEMP 방호시설의 SE 평가방법의 비교)

  • Chung, Yeon-Choon;Lee, Jongkyung;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1197-1200
    • /
    • 2014
  • Two test standards to be applied for evaluating shielding effectiveness of HEMP protection facilities, MIL-STD-188-125-1 and IEEE std. 299, provide different test results in spite of the same facility. In particular, at the frequency range of 10 kHz~20 MHz, it is confirmed that the test results by the IEEE Std. 299 are about 20~30 dB lower than the evaluated results by MIL-STD-188-125-1. These results are due to the different measurement conditions specified in the two test standards. Therefore, IEEE Std. 299 can be applied for the shortening of test distance, but the required SE performance based on MIL-STD-188-125-1 must be modified.

Evaluation of Seismic Performance of 2-Story Fire Protection Sprinkler Piping System (화재방호계통 복층구조 스프링클러 파이프라인 내진성능 평가)

  • Jeon, Jun-Tai;Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.458-464
    • /
    • 2014
  • Fire protection (sprinkler) piping system is an essential element for the energy supply and for the protection against the seismic-induced fire during and after an earthquake. The primary objective of this study was to understand the seismic performance of complex two-story piping system installed in a low-rise building subjected to bi-directional and three-directional earthquakes. The result of current study revealed that the displacement of the piping system in accordance with floor level was significantly different due to acceleration-sensitivity but the effect of the piping system due to the vertical direction earthquake was not significant.

An Experimental Study on the Determination of the Flow Rate for a Feasible $N_2$ Generator to Extinguish the Fire (소화성능이 있는 질소발생기의 방사량 결정에 관한 실험적 연구)

  • Jang, Young-Keun;Kim, Duk-Joo;Suh, Byung-Taek
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.54-60
    • /
    • 2010
  • An experimental study has been carried out to determine the flow rate for a feasible N2 generator to extinguish the fire, and this study analogized the correlations to determine the flow rate for $N_2$ generator considered an Oxygen concentration, protected enclosure, discharging pressure and discharging time. We manufactured simple protected enclosure for analyzing fire-extinguishing performance of the $N_2$ generator. As a $N_2$ gas is exhausted on protected enclosure, a various of Oxygen concentration is measured to analyze fire-extinguishing performance experimentally. The correlations determined as an uncertainty analysis for the Oxygen concentration deviations of the theoretical and experimental value. The analogized correlations is Q = (21 $\times$ V)/($O_2+{\zeta}{\cdot}P$)-V. In case of $300m^3$ protected enclosure, 0.8 MPa discharging pressure and $40m^3$/min $N_2$ flow rate, the Oxygen concentration is decreased below 15% within 3 minutes.

Study on KOLAS Certification Approach for Radiation Protection Products - Focusing on Masks (방사능 방호 제품에 대한 KOLAS 인증 방안 연구 - 마스크를 중심으로)

  • Namhee Park;Wookhyun Yeo;Sungjin Hong
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.815-825
    • /
    • 2023
  • Purpose: This paper aims to explore approaches for obtaining KOLAS certification for masks developed as protective equipment for use during evacuation processes in the event of a radiation disaster involving residents within a radiation emergency planning zone. Method: Various reports, papers, and data from the KOLAS accreditation bodies' websites were examined for this study. Result: Although domestic radiation disaster preparedness measures have been established to enhance resident protection, the distribution of protective equipment is limited to thyroid protection drugs. Supplementary support items like masks are necessary to prepare for radiation disasters. Currently, there is no KOLAS-accredited certification body for radiation protection masks. Conclusion: For masks that have established performance certification criteria, a dual process is required for KOLAS certification. This involves obtaining an official test report as an industrial respirator mask, receiving certification, and then obtaining a general test report based on internal standards.

A Study on Impact Resistance Properties with Composition Materials and Installation Conditions of Protective Panel (방호 패널의 구성 재료 및 설치 조건에 따른 내충격 특성에 관한 연구)

  • Seok, Won-Kyun;Kim, Young-Sun;Lee, Yae-Chan;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.715-726
    • /
    • 2023
  • This study suggested that protective panels should be installed as sacrificial members as a safety design method for structures with potential explosions such as hydrogen charging stations to minimize direct damage to the structure and have resilience. To this end, the focus of the experiment is on quantitatively evaluating the impact of the structure when the protection panel is installed closely or spaced apart from the structure in a high-speed collision situation of the projectile. The experimental design used steel plates instead of concrete structural members mainly used in the past for excellent reproducibility, and the impact of structural members was compared and analyzed through deformation differences on the back of the steel plate. In addition, the impact of changes in the physical properties of the elastic body used as a separation material for the protective member and the difference in shock wave transmission time according to the protective member and the elastic body on the structural member was investigated.

Consideration on the Performance Evaluation Criteria & Test Data Analysis for the Roadside Safety Facilities (차량방호안전시설 성능평가기준 및 시험데이터 분석에 관한 고찰)

  • Lee, Changseok;Kim, Changhyun;Suk, Jusik;Kang, Byungdo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • To verify the performance of roadside safety facilities, strength and occupant protection test are performed by evaluation criteria. Strength test use a truck and occupant protection test use a sedan. Strength perfomance is analyzed pass rate by post lateral resistance of the safety barrier. Occupant protection performance is analyzed from THIV(Theoretical Head Impact Velocity) and PHD(Post-impact Head Deceleration) by crash cushion test.

Developed a CBR Model for Civil Defense Evacuation Facilities (민방위 대피시설의 화생방 방호 모델 개발)

  • Park, Nam-Hee;Yeo, Wook-Hyun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.358-359
    • /
    • 2017
  • 본 논문에서는 민방위 대피시설을 조사한 결과를 바탕으로 대피시설에 적용하고 있는 화생방 설비의 개념을 분석하여, 우리의 실정 및 재난 특성에 따라 적절히 대응할 수 있는 대피시설의 설계 기준(안)을 도출하여, 획일화된 방호개념을 탈피한 대피시설의 구축 기반을 설정하기 위해 새로운 건물 내 대피시설(SIP) 개념을 도입하여, 일반 국민이 화생방관련 민방위 사태에 대응하여 사용할 수 있는 대피시설 계획의 설계 기준을 마련하는 것이다. 전체 대피시설 중 0.1%를 차지하고 있는 화생방 대피시설의 비율이다. 개소수로는 29개소이며, 이 시설은 일반 주민은 사용할 수 없는 충무지휘용 대피시설이다. 이는 화생방 재난 및 사고 발생 시 일반 주민들은 대피할 공간이 전혀 없다는 것을 의미한다. 본 연구에서는 미국의 대피시설 계획 설계내용을 검토하고 국내 시설과 비교하여 대피시설의 성능을 비교 검증하고 화생방 대피시설의 일반적/기술적 구축 조건 모델을 구성하였다.

  • PDF