• Title/Summary/Keyword: 방출 농도계수

Search Result 44, Processing Time 0.035 seconds

Decomposition and, Nitrogen, Phosphorus and Potassium Dynamics of Pinus thundbergii Needle Litter (해송엽(海松葉) Litter의 분해(分解)와 N, P 및 K의 동태(動態))

  • Yi, Myong-Jong
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.3
    • /
    • pp.303-310
    • /
    • 1991
  • Seasonal patterns of decomposition and nutrient release from the needle litter were examined using litter-bags in coastal Pinus thunbergii forests in nothern Kyushu, Japan. Dry matter losses from decomposing needle litter were smillar in all standsover a experimental period. Mass loss in dry weight is lost rapidly during the first year, and thereafter the rate of loss slows. Litter lost approximately 40% of initial mass in 1 yr. The predicted decay constant, k values ranged from 0.5 to 0.6 Decomposition half-times($t_{0.50}$) ranged from 1.1 to 1.4 year. In the decomposing needle litter, the concentrations of N and P generally increased with time while the concentration of K decreased. A decrease in absolute amount was noted for K during decomposition while in an increase was found for N. The order of mobility of elements was K>P>N. Mineralization phase of N had not appeared during the experiment.

  • PDF

A Systematic Approach for Selective Epitaxial Growth of Silicon using Transport Phenomena, Thermodynamics, and Microscopic Simulation (이동현상, 열역학, 미시적 이론 연구릉 통한 선택적 단결정 실리콘 성장공정의 전산모사)

  • 윤종호;박상규
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.4
    • /
    • pp.466-481
    • /
    • 1994
  • 차세대 집적회로 제조공정에 있어 핵심기술인 선택적 단결정 실리콘 성장공정에 대한 이동현상, 열역학, 미시적 전산모사를 수행하여 다각적인 분석과 이해를 시도하였다. 첫째, 실리콘 단결정 성장 공 정에 가장 많이 사용되는 배럴 반응기를 대상으로 유한 요소법을 이용하여 이동현상적 이론연구를 수행 하였다. 반응기내의 기체속도 분포, SiH2Cl2 농도분포를 각각 구하였으며 압력, 기판온도, 총유량 HCl 유 량변화 등의주요공정변수가 증착율과 균일도 지수에 미치는 영햐을 고찰하였다. 이러한 연구를 통하여 저온, 저압, 총유량이 많고 첨가되는 HCl 유량이 작은 경우가 균일도 확보를 위하여 적합한 조업조건임 을 알수 있었다. 둘째 Si-H-Cl 계에 대한 열역학적 기체의 Cl/H비가 낮은 경우가 선택적 실리콘 증착 에 적합함을 알수 있었다. 셋째, Monte Carlo법을 이용한 선택적 실리콘 미세박막 성장패턴에 관한 이 론 연구를 수행하여 종횡비, 재방출, 표면확산에 따른 박막증착 패턴의 변화를 고찰하였으며 표면확산이 선택도 상실 현상의 중요한 원인이 될 수 있음을 발견하였다. 또한 최상의 선택도 확보를위해서는 낮은 부착계수와 낮은 표면확산계수를 유지해야 됨을 알수 있었다.

  • PDF

A Study on the Correction of Spectral Line Overlaps for the Determination of Rare Earth Elements by X-Ray Fluorescence Spectrometry (X-선 형광분광법에 의한 희토류원소 분석에서 스펙트럼선 겹침 방해의 보정에 관한 연구)

  • Young-Man Kim;Young-Sang Kim;Yoon-Chang Park;Chong-Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.538-547
    • /
    • 1986
  • The 8 rare earth elements were determined in the monazite concentrates by X-ray fluorescence spectrometry. The spectral line overlapping interferences from the other elements were investigated and the correction methods of interferences were studied using line overlap coefficients. The coefficients were calculated from the ratios of the intensities measured at the diffracted angle (2${\theta}$) of the analytical lines of other elements to the intensity of pure rare earth oxide. The coefficients were used to correct the line overlaps by a regression analysis. The linearities of calibration curves from the corrected intensities were remarkably improved, and their standard deviations were decreased. The analytical results agreed with that of the inductively coupled plasma(ICP) spectrometry within an allowable error range.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere (대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定))

  • Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.5-13
    • /
    • 1979
  • A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also investigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments.

  • PDF

Studies on the Behaviour of Radionuclides in the Soil-Plant System;1) On the Uptake of Cesium-137 by Soybean (토양(土壤)-식물계(植物界)에 대(對)한 방사성핵종(放射性核種)의 거동(擧動)에 관(關)한 연구(硏究);I. 대두작물(大豆作物)에 의(依)한 Cs-137의 흡수이행(吸收移行))

  • Ryu, Joon;Kim, Jae-Sung;Lee, Young-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.1
    • /
    • pp.30-34
    • /
    • 1983
  • The present study was carried out to determine the effect of a radionuclide, cesium-137, in soybean, which is an element released usually from nuclear facilities. Soybean plants were grown on the pots treated with cesium-137 $0.5{\sim}60{\mu}Ci/1kg$ soil and the uptake, translocation and accumulation of the radiocesium in the plant parts were measured at different growth stage. The results are summarized as follows: 1) Visual toxic symptoms on the plants due to treatment of radioactive cesium were not observed up to $60{\mu}Ci/10Kg$ soil in a pot. 2) The uptake of cesium-137 in soybean plant was increased with increment of concentration applied, while the uptake of potassium was proportionally decreased, indicating to have an ion antagonistic relationship between them. 3) The absolute amounts of cesium-137 in the plants were gradually increased by the pod setting stage, but rather reduced at harvesting stage. The accumulation occurred more in the leaves and stems than the soybean seeds. 4) The rate of uptake was ranged from 0.069 to 0.005 with proportional decrease by increasing concentration applied and the rate of Cs-137 translocation from plants to seeds was averaged 38.6% in soybean plant. The concentration coefficient was 0.04 in the soybean seeds from the pots treated with $20{\mu}Ci$ of cesium-137 and decreased with increment of cesium-137 applied.

  • PDF

A New Analytical Method for the $Dy^{3+}$ Ion Using the Luminescence Enhancement by the Treatment of o-Phenanthroline on the TLC Plate (TLC Plate에서의 발광증폭 및 o-Phenanthroline에 의한 Energy Transfer를 이용한 $Dy^{3+}$ 이온의 미량 분석법)

  • Jeong, Hyuk
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.386-393
    • /
    • 1998
  • A new analytical luminescence method for the $Dy^{3+}$ ion was studied using the luminescence enhancement by the treatment of the o-phenanthroline on the TLC plate. Compared to the specific emission intensities of the ion in water solution, if the ion solution is spotted on the TLC plate, the luminescence intensities were extremely enhanced. There was additional enhancement effect of the luminescence intensities of the ions on the TLC plate, if the ion on the TLC plate is treated with o-phenanthroline. Based on the luminescence enhancement, the detection limit was improved by more than 4 order of magnitude compared to that of solution sample. The dynamic ranges and correlation coefficients of the calibration curves near the detection limit were 102 order and ~0.99, respectively. The energy-transfer mechanism was explained for the theoretical back ground of the luminescence enhancement.

  • PDF

Stabilization and Release Behavior of W1/O/W2-Type Multiple Emulsions Using Various Block Copolymer Emulsifier and Stabilizer (다양한 Block Copolymer를 유화제 및 안정화제로 사용한 W1/O/W2-Type 다중에멀젼의 방출거동 및 안정성)

  • Haw, Jung-Rim;Kim, Cheol-Hun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.560-567
    • /
    • 1997
  • A new approach to obtain stable $W_1/O/W_2$ multiple emulsions has been studied ; The basis of the interfacial interaction between a PCL-PEO-PCL triblock copolymer and a lipophilic emulsifier in the dispersed oil phase was examined. $W_1/O/W_2$ multiple emulsions were prepared by the two-step method. Arlacel P-l35 was used as a liphophilic emulsifier and Synperonic PE/F 127 as a hydrophilic one. Eutanol-G was used as an oil phase. NaCl was encapsulated within the multiple emulsion droplets as the internal marker and its release rate studies were carried out. The suability of the multiple emulsions have been assessed by measuring Separation Ratios(%) and microscopic observations. The release of NaCl was significantly reduced in $W_1/O/W_2$ multiple emulsions containing PCL-PEO-PCL triblock copolymer(2k-4k-2k or 6k-4k-6k) in the oil phase. It may be concluded that the copolymer and the emulsifier form effective interfacial complex to enhance stability and to control the release rate. The effective diffusion coefficients of the NaCl were estimated as $2.64{\times}10^{-15}s$and $3.23{\times}10^{-16}gcm^2/s$ for the $W_1/O/W_2$ multiple emulsion containing 1.2 wt % of PCL-PEO-PCL triblock copolymers with compositions of 2k-4k-2k and 6k-4k-2k, respectively. The rate of release decreased with the increase of the initial concentration of NaCl. The results were examined in view of Higuchi mechanism. A kinetic model which is similar to the model for release of dispersed drugs from a polymeric matrix was found to be suitable for the release of NaCl from $W_1/O/W_2$ multiple emulsions.

  • PDF

방사성폐기물 소각시설의 현황 및 안전지침

  • 박원재;이병수;이승행;김준형;서용칠
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.603-618
    • /
    • 1995
  • 원자력 발전소 및 동위원소 사용기관에서 발생되는 가연성 고체 폐기물 및 유기폐액의 소각기술의 활용에 있어서 이의 안전성 확보를 위한 기술적 기준의 설정을 위한 고려인자들을 조사하였다. 국내외의 소각기술 활용현황을 알아보았고 본 기술의 국내 도입시 필요한 기술적 안전지침에 관한 외국의 사례를 조사하고 국내 관련 규정도 검토, 비교, 분석하여 주요 고려항목을 도출하였다. 안전성 확보를 위한 고려 항목을 크게 일반산업시설 적용항목, 원자력시설 상 안전조건, 소각시설의 기술적 요구사항, 기타 제반사항으로 나누어 제시할 수 있었다. 이들 내용은 기존 원자력 및 환경시설에 적용되는 안전성분석보고서 및 환경영향평가서로 작성될 수 있다고 보았으며 시설의 개요, 시설의 기술적 사항과 이에 따르는 안전을 위한 조건, 폐기물의 인수조건 등이 포함되며 기존 관련 법규의 적용 및 확인이 필요하였다. 기술적 사항에는 공정의 제염계수, 연소효율, 소각재의 형상, 배기가스의 방출농도, 작업자 및 인근주민의 피폭등이 확인되어야 하며 소각재의 처리방법 및 조건이 제시되어야 하고 소각재의 침출특성 등이 주요한 인자라고 보았다. 아울러 소각대상폐기물의 인수조건이 명시되어 소각성능에 따른 이의 안전성이 입증되어야 한다. 따라서 인허가 후 건설된 시설에서의 사용전 시험소각절차의 제시 및 이에 대한 관련 규제기관의 검사제도가 있어야 하며 품질보증절차 역시 관련지침에 따라 실시되어야 한다. 이와 같은 내용을 포함하는 안전기술지침의 설정이 절대적으로 필요하며 본 연구조사 결과의 활용이 기대된다.

  • PDF

Evaluation of Basin-Specific CH4 emission flux from Intertidal Flat Sediments of Sogeun-ri, Taean, Mid-west Korea (한국 서해안 태안 소근리 갯벌의 메탄가스 발생량 특성)

  • Lee, Jun-Ho;Jeong, Kap-Sik;Woo, Han Jun;Kang, Jeongwon;Lee, Dong-Hun;Jang, Seok;Kim, Seong-Ryul
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.281-291
    • /
    • 2014
  • In March to August 2013, the emission of gases ($CH_4$, VOC, $CO_2$, $O_2$, and LEL) was measured three times from the intertidal flat sediments at Sogeun-ri, Taean-gun, in the Mid-western seashore of Korea by using chamber method. After analyzing gas emission concentrations inside of flux enclosure chamber by using a GC equipped with Agilent 6890. The gas emission fluxes were calculated from a linear regression of the changes in the concentrations with time. The ranges of gas flux during the experimental period were $+0.06{\sim}+0.60mg/m^2/hr$ for $CH_4$, $+58.45{\sim}+95.58mg/m^2/hr$ for $CO_2$, $-0.02{\sim}-0.20mg/m^2/hr$ for $O_2$, and $-0.60{\sim}+0.65mg/m^2/hr$ for VOC, respectively. The flux measurement results revealed that $CH_4$ fluxes during March in the relatively low sediment temperature ($14.5^{\circ}C$) were significantly higher ($+0.60mg/m^2/hr$) than during June and August ($+0.06{\sim}+0.18mg/m^2/hr$) in high sediment temperature ($32.0{\sim}36.8^{\circ}C$). $CH_4$ flux to mean size of sediments and temperature of inner chamber exhibited strong positive correlation ($R^2=-0.97$ and $R^2=-0.89$, respectively).