• Title/Summary/Keyword: 방진장치

Search Result 55, Processing Time 0.022 seconds

Examination for Structural Safety of Floating Slab Design and Shear Connector (플로팅 슬래브 설계와 전단연결재의 구조안전성 검토)

  • Park, Sung-Jae;Ma, Chang-Nam;Lee, Jong-Ho;Lee, Du-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.374-374
    • /
    • 2011
  • Recently the construction of railway sections passing the central area of cities and stations under railway lines are increasing, and then it is urgently required to take the countermeasures against the railway vibration and the second-phase noise radiated from it. The most efficient countermeasure, out of technologies developed up to now, is the floating slab track which is the track system isolated from the sub-structure by springs. In other countries, the source technologies for anti-vibration design and vibration isolator - one of key components - have been developed and many installation experiences have been accumulated. However, in Korea, since the system design technology and technologies for key components are not yet developed, the foreign system are being introduced without any adjustment, and the key component, vibration isolator, depends on imports. In this study, based on the results of previous studies of the dust-control device installation using the slab and go through time after lifting impressive when stepped on power generated by the cross-section of the slab and shear connection re-examined the structural stability.

  • PDF

Analytical Study on Fatigue Behavior of Resilient Pad for Rail Fastening System (레일체결장치용 방진패드의 피로거동에 관한 해석적 연구)

  • Choi, Jung-Youl
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.405-410
    • /
    • 2021
  • In this study, a finite element analysis was performed applying a nonlinear material model and fatigue load conditions to evaluate the service life and spring stiffness of the resilient pad for rail fastening system. As a result of the fatigue analysis, the rate of change in spring stiffness compared to the initial condition was about 16%, indicating that fatigue hardening occurred. As for the stress generated in the longitudinal direction of the resilient pad, the difference between the stress generated at the center and the edge was about 10 times or more. In addition, it was analyzed that the equivalent stress of the outer boundary was more than twice as large as that of the central part. Therefore, it was analyzed that the damage and deformation of the resilient pad are the corners of the resilient pad under actual service conditions. The fatigue life diagram of the resilient pad (S-N curve) was derived using the equivalent stress of the resilient pad according to the fatigue cycles. Using the fatigue life diagram of the resilient pad derived in this study, it is considered that it can be used to predict the fatigue life under the relevant conditions by calculating the equivalent stress of the resilient pad under various load conditions.

Development of the Vibration Absorption System for the Power Tiller Trailer (동력경운기 트레일러 방진장치 개발)

  • 홍종호;강인철;이홍주;이성범;김성엽
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.69-76
    • /
    • 2003
  • 청과류는 수송과 취급기간 중에 충격, 마찰, 눌림, 타박 등에 지속적으로 노출된다. 그러므로 농산물의 품질을 저하시키는 물리적인 손상을 최소화하기 위해 최선의 처리와 수송방법을 선택할 필요가 있다. 충격흡수 시스템이 갖추어진 대형 냉동 트레일러에 체리, 복숭아, 배, 토마토를 수송했을 때 3.5Hz에서 수직가속도가 가장 크게 나타났고 9-25Hz에서는 이보다는 약간 감소했다. (중략)

  • PDF

A study on the evaluation method of isolation system for industry structure (산업용 구조물의 방진장치 성능 평가 방법에 관한 연구)

  • Jeoung, Jeoung-Kyo;Park, Hae-Dong;Kim, Doo-Hoon;Choi, Hyun;Park, Sang-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.170-175
    • /
    • 2000
  • Vibration and vibration-induced noise, major sources of occupant complaint, are increasing in modern buildings, Lighter weight construction and equipment located in penthouses or intermediate level mechanical rooms increase structure-bone vibration and noise transmission. In this paper discusses about testing vibration isolation systems and about the effectness of floor flexibility for vibration transmission.

  • PDF

An Electro-magnetic Air Spring for Vibration Control in Semiconductor Manufacturing (반도체 생산에서 진동 제어를 위한 전자기 에어 스프링)

  • Kim, Hyung-Tae;Kim, Cheol-Ho;Lee, Kang-Won;Lee, Gyu-Seop;Son, Sung-Wan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1128-1138
    • /
    • 2010
  • One of the typical problems in the precise vibration is resonance characteristics at low frequency disturbance due to a heavy mass. An electro-magnetic(EM) air spring is a kind of vibration control unit and active isolator. The EM air spring in this study aims at removing the low frequency resonance for semiconductor manufacturing. The mechanical and electronic parts in the active isolator are designed to operate under a weight of 2.5 tons. The EM spring is floated using air pressure in a pneumatic elastic chamber and actuated by EM levitation force. The actuator consists of a EM coil and a permanent magnetic plate which are installed inside of the chamber. An air mount was constructed for the experiment with a stone surface plate, 4 active air springs, 4 gap sensors, a DSP controller, and a multi-channel power amp. A PD control method and operating logic was applied to the DSP. Simulation using 1/4 model was carried out and compared with the experiments. The time duration and maximum peak at resonance frequency can be reduced sharply by the proposed system. The results show that the active system can avoid the resonance caused by the natural frequency of the passive system.

Influence of Materials and Embedded Depth of Isolation Barrier on Ground Vibration - With Point Loaded Centrifugal Tests - (진동 차단벽재료 및 타설심도가 방진효과에 미치는 영향 - 점가진 원심모형실험을 중심으로 -)

  • 이강일;김태훈
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.41-49
    • /
    • 2004
  • In general, open trenches or in-filled trenches have been used to isolate transmitting of vibration. Recently alternative methods, in which various materials are used for wall barriers have been proposed and performed in several sites. Although the effects of these methods are verified, resonable and qualitative evaluation methods have not yet been conducted. It may be because many factors, such as the characteristics of vibration sources, ground condition, and parameters of wall barrier are coupled complicatedly. In this study, a series of centrifugal modelings were conducted in order to examine the evaluation method of a vibration wall barrier when point load transmits to the surface. The experiments were performed with different stiffness of wall barriers and different depths of installations. Using the results obtained from tests, effects of those variables on the efficiency of vibration barrier were analyzed. Through this investigation we observed vibration transmission of under ground, and verified the applicability of ball dropping system which was developed in this study.

Load-Displacement Relationship of Passive Vibration Units Composed with a Spring and Vibration-Proof Rubbers (스프링과 방진고무가 융합된 제진장치의 하중-변위 관계)

  • Mun, Ju-Hyun;Im, Chae-Rim;Wang, Hye-Rin;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.226-234
    • /
    • 2021
  • The objective of this study is to establish the fundamental design data for axial load-displacement relationship under axial monotonic or cyclic responses of seismic damping·isolation (SDI) units developed for ceiling structures. The main parameters include the installation of a spring, the number of rubber layer, prestress stress of bolts for connector between the spring and rubbers, and loading type. Test results showed that SDI units with a spring in the core and higher prestress stress of bolts tended to be higher stiffness at the ascending branch and more ductile behavior at the descending branch. This trends more notable for the specimens under monotonic load rather than cyclic loads. Consequently, the energy dissipation of SDI unit can be optimally designed with the following conditions: installation of a spring within 3-layer rubbers and prestress applied to the bolts at 10% of their yielding strength . When compared with the experimental tension capacity of the developed SDI units, the predictions by JIS B 2704-1 and KDS 31 00 are conservative under monotonic loading but higher by approximately 10% under cyclic loading.

신자재: 방진 및 내진용 배관 고정장치 개발 - 주헌건설(주)

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.247
    • /
    • pp.58-59
    • /
    • 2011
  • 주헌건설(주)은 지난해 6월 자체 개발한 내진 스프링가대가 특허(제10-0962993호)를 획득함에 따라 본격생산에 들어갔다. 내진 스프링가대는 펌프 등 실비기기의 자체진동을 방지하고 지진 발생시 충격을 흡수해 산재사고 예방 및 내진 안전성을 확보하는 장치이다. 이 제품은 지난 2010년 10월 "제4차 UN 재해위험 경감을 위한 아시아 각료회의"의 부대행사로 열린 재해경감 방재산업전에 출품해 호평을 받았다. 또한 배관의 신축 팽창을 자체 흡수하고 각종 슈 대신 절연 유볼트로 시공하므로 원가절감 효과가 있으며 타 공정과의 간섭 없이 시공할 수 있는 장점이 있다.

  • PDF

A Study on the Vibration Characteristics of Camera Module for Aerial Reconnaissance Considering Vibration Isolator (방진을 고려한 항공 정찰용 카메라 모듈부의 진동특성에 관한 연구)

  • Lee, Sang-Eun;Lee, Tae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.545-553
    • /
    • 2012
  • A Gimbal structure system in observation reconnaissance aircraft is made up of camera module and stabilization drive device supporting camera module. During flight for image recording, the aircraft undergoes serious accelerations with wide frequencies due to several factors. Though base excitation of stabilization drive device induces vibration of camera module, it must get the stable and clean images. To achieve this aim, acceleration of camera module must be reduced. Hence, vibration isolators were installed to stabilization drive device. Considering isolators and bearings in the stabilization drive device, vibration characteristics of gimbal structure system were analyzed by finite element method. For three translational direction, acceleration transmissibility of camera module was calculated by harmonic responses analysis in the frequency range of 5 ~ 500 Hz. In addition to, sine-sweep experiment were performed to prove correctness of present analysis.