• Title/Summary/Keyword: 방전시간

Search Result 541, Processing Time 0.035 seconds

Estimation of Discharge Current Waveshapes in Short Gap Discharge by One Antennal Method (1 안테나 법에 의한 미소 간극의 방전 전류파형 추정)

  • 김기채;이광식;이동인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.499-505
    • /
    • 1998
  • This paper presents the method for an estimation of discharge current waveshapes in short gap discharge by a radiated electromagnetic field. The method of currentwaveform estimation described is using the one antenna method(single field method) with a measured electric or magnetic fields at given field point by a time domain antenna. In order to verify the availability of the estimated theory, the discharge current waveshape estimation was performed by one antenna method using the measured electric fields of Wilson & Ma and compared with experiments.

  • PDF

Characteristic of Mercury free Flat fluorescent Lamp as Driving frequency (주파수 변화에 따른 무수은 평판 형광 램프의 특성)

  • Lee, Myoung-Ho;Lim, Kee-Joe;Lim, Min-Su;Lee, Mun-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2075-2078
    • /
    • 2005
  • 본 논문은 무수은 평판 형광램프의 구동원리를 해석하기 위하여 주파수 변화에 따른 벽전하와 벽전압 특성이 방전특성에 미치는 영향을 연구하였다. 펄스폭 $9[{\mu}s]$, 300[ns]의 전압 상승 시간을 갖는 펄스파로 방전시켰다. 벽전하, 정전용량, 벽전압의 전기적 특성은 인가된 전압, 전류 파형으로부터 계산하였다. 이때 구동 주파수는 20[kHz]에서 40[kHz]까지 변화시키면서 방전 전후의 정전용량 및 Q-V특성 곡선을 해석하였다. 주파수가 증가하면서 전극간의 정전용량 $C_p$ 방전공간상의 정전용량 $C_o$는 변화를 보이지 않았으나 방전공간과 전극사이의 정전용량 $2C_g$는 증가하는 경향을 보였다. 또한 주파수가 증가하면서 방전개시 전압은 감소하였으며 효율은 감소하는 경향을 보였다.

  • PDF

A Study on the Discharge Characteristics by the narrow width address pulse for Plasma Display Panel (플라즈마 디스플레이 패널의 세폭 어드레스 방전특성에 관한 연구)

  • Ryeom, Jeong-Duk;Kwak, Hee-Ro
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.205-210
    • /
    • 2006
  • 어드레스-표시 동시 구동방식에 의한 고속 구동기술을 개발하기 위하여 PDP의 어드레스 기간에 인가하는 주사 펄스의 폭에 의한 방전특성을 실험용 PDP를 사용하여 실험하였다. 본 연구에서는 주사 펄스의 폭과 주사 펄스와 이어서 인가되는 첫 번째 서스테인 펄스 사이의 시간간격을 변화시키면서 어드레스 방전특성을 측정하였다. 실험결과 주사펄스의 폭이 $1.3{\mu}s$ 이하로 좁아지면 어드레스 방전의 벽전하 대신에 공간전하로 서스테인 방전이 유도되므로 각 전극에 인가하는 펄스의 전압조건이 달라져야 한다는 것을 알았다 또한 주사 펄스폭이 좁아지면 어드레스 방전개시전압이 크게 상승함을 알았다. 실험결과 12개의 서브필드를 가지며 1080개의 주사선을 가지는 full-HDTV급 PDP를 구동시킬 수 있는 조건인 $0.7{\mu}s$ 수준의 주사 펄스폭 이상에서 약 10V의 일정한 서스테인 구동마진이 얻어짐을 알았다.

  • PDF

EXPERIMENTAL ESOPHAGEAL INJURY WITH DISC BATTERY (수은전지에 의한 식도손상)

  • 박언우;남부현;나기상;유장열;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.14-14
    • /
    • 1987
  • 최근 수은전지의 사용이 증가함에 따라 이에 의한 식도이물의 가능성도 증가하게 되었다. 저자는 수은전지에 의한 식도손상을 관찰하기 위하여 가토(1.7kg~2.5kg)에서 수은전지(충전된 전지, 방전된 전지)와 같은 모양, 크기의 철판(대조군)을 상절치에서 약 15cm되는 식도에 삽입 후 시간별로(1, 3, 6, 12, 24시간)육안적, 조직학적 관찰을 하였다. 충전된 전지를 삽입한 군에서는 삽입 후 1시간부터 식도손상을 보였고 시간경과에 따라 그 정도가 심해졌으며, 방전된 전지를 삽입한 군에서는 삽입후 3시간부터 식도손상을 보였고 시간 경과에 따라 그 정도가 심해졌으나 충전된 전지군에 비하여는 경한 손상을 보였으며, 대조군에서는 삽입 후 24시간까지 손상을 보이지 않았다. 따라서 수은전지에 의한 식도이물은 조기에 심한 식도손상을 초래하므로 가능한 한 신속히 제거해야 할 것으로 생각된다.

  • PDF

코로나 방전을 이용한 하이브리드 사이클론 집진 장치 특성 연구

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.259-260
    • /
    • 2012
  • 산업화가 발달됨에 따라 대기 오염 물질은 점차 증가하고 있는 추세에 있고 특히 기름 및 석탄 연소 보일러, 자동차, 제철, 시멘트 플렌트, 소각로 등은 미세 분진을 발생시키는 주원인이 되어 왔다. 최근 대기환경법은 오염 분진의 중량 규제로부터 $10{\mu}m$ 미만의 PM10에서 $2.5{\mu}m$ 미만의 PM2.5의 미세 분진에 대한 규제로 점차 심화되고 있으나, 이러한 미세분진은 고전적인 제거 방법으로는 매우 어려우며 고가의 HEPA 필터를 사용하여야 한다. 한편 코로나 방전을 이용하는 전기 집진은 미세 먼지 제거에 매우 효율적이어서 $1{\mu}m$ 미만의 미세 분지도 99%까지 제거가 가능하다는 장점이 있지만 입자크기가 클 경우에는 효율이 떨어지는 단점이 있다. 한편 사이클론 집진기는 매우 오래전부터 개발되어 사용되어 왔는데 가격이 저렴하고 운영비가 적게 들며 $10{\mu}m$ 이상의 먼지는 99% 이상 제거가 가능하여 산업현장에서 오랜 기간 사용되어 왔지만 입자크기가 $10{\mu}m$ 미만으로 가면 집진율이 급격히 떨어지는 단점을 가지고 있다. 본 연구에서는 기존의 사이클론 집진기의 구조를 기본으로하여 사이클론 집진기 내부에 플라즈마 방전을 설치하여 원심력에 의한 집진과 코로나 방전에 의한 전기 집진을 동시에 수행할 수 있도록 하이브리드 사이클론 집진기를 제작하였다. 제작된 사이클론 집진기는 직경 30 cm 높이 120 cm의 사이클론 구조를 가지고 있으며 1 hp의 터보송풍기를 장착하여 $20m^3$/min 이상의 유량을 처리할 수 있도록 설계 제작되었다. 제작된 하이브리드 사이클론 집진기의 성능을 평가하기 위하여 $10m^3$의 체적을 가지는 테스트 챔버 내부에 사이클론 집진기를 설치하고 향을 태워 미세 먼지를 발생시킨 후 다양한 조건에서 집진 성능을 측정하여 보았다. 미세 먼지의 경우 사이클론을 작동시키지 않아도 테스트 챔버 벽면에 흡착되어 초기에는 급격히 감소하는 경향을 보여주나 일정 시간이 경과한 후에는 매우 느리게 감소하는 현상이 관찰 되었다. 코로나 방전을 하지 않고 오존 파괴기에 활성탄만 충진한 상태에서 사이크론을 작동시킬 경우 지속적으로 천천히 감소하는 경향을 보여주었으며, 코로나 플라즈마를 방전시킨 경우 미세 먼지는 HEPA filter를 장착한 것보다도 조금 빠르게 미세먼지를 제거하였다. 챔버 내부의 미세먼지가 초기 값의 1/10에 도달하는 시간은 코로나 방전 전류가 증가할수록 짧아지는 경향을 보여주었으며 최적 조건에서 100초 이내에 90% 이상 제거가 가능하였다. 하이브리드 사이클론 집진기는 집진 뿐 만 아리라 VOC 성분도 분해가 가능하여 유해물질을 제거하는 능력이 있다. 유해 가스 제거 능력을 실험하기 위하여 분진제거 실험에 사용된 챔버 안에 아세톤을 증발시켜 50 ppm이 되도록 한 후 다양한 조건에서 유해물질 제거 실험을 수행하였다. 미세먼지와는 달리 장비를 작동하지 않을 경우 매우 느리게 아세톤 농도가 감소하였다. 이는 미세 먼지와는 달리 흡착이 발생하지 않고, 측정 챔버 자체가 완전한 밀폐가 이루어지지 않아 자연적으로 조금씩 외부로 누출되기 때문으로 판단된다. 코로나 플라즈마만 방전시켰을 경우 초기 농도의 80%가 제거되는데 걸리는 시간은 약 28분 정도로 코로나 플라즈마가 VOC 제거에 효과가 있음은 확인하였으나 제거율이 그리 높지 않음을 알 수 있었다. 한편 오존 파괴를 위해 활성탄으로 충진 된 오존파괴기를 통과시킨 경우는 약 12분 경과 후 80%가 제거됨을 확인할 수 있었으나 그 이후에는 VOC의 감소가 매우 느리게 진행됨을 알 수 있었다. 한편 활성탄 대신 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과한 경우 약 3분 정도 경과 후 80%의 아세톤이 제거됨을 관찰할 수 있었으며 코로나 플라즈마를 작동시키면서 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과시킨 경우 약 2분 정도 경과 80% 이상의 아세톤이 제거되어 코로나 플라즈마와 복합촉매를 사용할 경우 VOC 성분이 효과적으로 제거됨을 알 수 있었다.

  • PDF

Optimum Conditions of Dismantlement for Recovery of Valuables from Spent Lithium Primary Batteries (폐일차리튬전지로부터 유가금속을 회수하기 위한 해체공정의 최적화)

  • Yoo, Koungkeun;Kim, Hong-in;Sohn, Jeong-Soo
    • Resources Recycling
    • /
    • v.28 no.4
    • /
    • pp.51-58
    • /
    • 2019
  • Dismantlement of lithium primary batteries without explosion is required to recycle the lithium primary batteries which could be exploded by heating too much or crushing. In the present study, the optimum discharging condition was investigated to dismantle the batteries without explosion. When the batteries were discharged with $0.5kmol{\cdot}m^{-3}$ sulfuric acid, the reactivity of the batteries decreased after 4 days at $35^{\circ}C$ and after 1 day at $50^{\circ}C$, respectively. This result shows that higher temperature removed the high reactivity of the batteries. Because loss of metals recycled increases when the batteries are discharged only with the sulfuric acid, discharging process using acid solution and water was newly proposed. When the batteries were discharged with water during 24 hours after discharging with $0.5kmol{\cdot}m^{-3}$ sulfuric acid during 6 hours, the batteries discharged were dismantled without explosion. Because decrease in loss of metals was accomplished by new process, the recycling process of the batteries could become economic by the 2-step discharging process.

Ac-PDP에서 어드레스 구간에 ramp pulse의 적용

  • 정봉규;김지선;황호정;권시옥
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.108-111
    • /
    • 2004
  • 본 논문은 He-Ne-Xe의 삼원가스를 사용하는 ac-PDP에서 어드레싱 시간을 줄이고 휘도를 높이기 위하여 기존의 ADS(Address Display period Separated) 구동 방식에서 어드레스 구간을 변형하였다. 즉, 어드레스 구간에 기존의 사각 파형 대신에 기울기 파형을 사용하여 그 영향을 고찰하였다. 또, 기울기파의 경사를 변화시키면서 그 때의 벽전하와 방전전류, 휘도, 효율을 측정하고 그 결과를 고찰하였다. 그 결과, 벽전하의 양이 25%, 휘도가 14%, 효율이 13% 증가하였고, 방전응답시간을 줄일 수 있었다.

  • PDF

The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques (신호처리 기술에 의한 부분방전 방사전자파의 특징 추출)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2002
  • In recent years, diagnostic techniques have been investigated to detect a partial discharge(PD) in a high voltage electrical equipment. Because PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise, the accuracy and credibility of PD measurement might be influenced by surrounding interference. Using the technique of PD detection by electromagnetic wave, we have studied the characteristics of both PD and substation-in interference signal. Also, we propose a wavelet packet transform based technique to perform a feature extraction from the interference and PD signal and a classification of the extracted features. The results show that time-frequency characteristics between PD and interference can be obviously distinguished. It is helpful for the development of the insulation diagnosis technique.

Estimation of Discharge Current Waveshapes in Short Gap Discharge by Radiated Electromagnetic Fields (방사 전자파에 의한 미소 간극 방전원의 방전 전류파형 추정)

  • 김기채;이광식;이동인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.259-267
    • /
    • 2000
  • This paper presents the method for an estimation of discharge current waveshapes in short gap discharge by radiated electromagnetic fields. The method of current waveform estimation described is using the one antenna method(single field method) and two antennal method(complex field method) with a measured electric or magnetic fields at given field point by a time domain antenna. In order to verify the availability of the estimation theory, the discharge current waveshape estimation was performed by one and two antenna methods using the measured electric fields of Wilson & Ma and compared with experiments.

  • PDF

A Study on the High Speed Driving for Plasma Display Panel (플라즈마 디스플레이 패널의 고속구동에 관한 연구)

  • Ryeom, Jeong-Duk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.141-145
    • /
    • 2005
  • 어드레스-표시 동시 구동방식을 사용한 고속 구동기술을 개발하여 실험용 PDP에 적용하였다. 연구에서 주사 펄스의 폭과 주사 펄스와 첫 번째 서스테인 펄스 사이의 시간간격을 변화시키면서 어드레스 방전 특성을 측정하였다. 실험결과 이 고속 구동기술은 어드레스 방전의 벽전하 대신에 공간전하로 서스테인 방전을 유도한다는 것을 알았다. 그리고 12개의 서브필드를 가지며 1080개의 주사선을 가지는 full-HDTV급 PDP를 구동시킬 수 있는 조건을 만족하는 $0.7{\mu}s$ 수준의 주사 펄스폭과 20V의 어드레스 구동마진을 실현하였다.

  • PDF